1.Changes of adhesion,aggregation and factor Ⅲ activity of platelet apheresis concentrates in vitro after long-term cryo-preservation at-80 ℃
Lingkui KONG ; Weigang ZHU ; Wen XIONG ; Xueme LI
Journal of Third Military Medical University 2003;0(17):-
0.05).However,during the thawing process of the APCs,four out of ten and three out of eleven APCs samples appeared aggregative reaction after cryo-preservance for 4 and 5 years,respectively.The majority of the samples extensively lost their factor Ⅲ activities in the fifth year storage.When fresh,liquid platelets were stored at room temperature(22 ℃),the in vitro adhesion and agglutination gradually decreased and statistic differences were observed in 72 h(P
2.Comparison of different models of Sysmex hematology analyzers used for red blood cell count and related parameters
Li KONG ; Jianping WANG ; Lanting TONG ; Weigang CHEN ; Yintao PEI ; Yufei SHI ; Nengjiao GAO
Chinese Medical Equipment Journal 2017;38(5):95-98
Objective To evaluate Sysmex XS-800i,XS-1000i and XE-2100D hematology analyzers when used to detect RBC count,hemoglobin (HGB),hematocrit (HCT),mean corpuscular volume (MCV),mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC).Methods XE-2100D hematology analyzer was calibrated after performance evaluation,and the three analyzers had the intra-day precisions measured with three levels of whole-blood quality control materials.Totally 50 whole-blood specimens were detected with the three analyzers respectively,and statistical analyses and clinically acceptable performance evaluation were carried out on RBC count and the obtained results.Results XE-2100D hematology analyzer met the clinical requirements,and the three analyzers all gained high precisions when used to measure the parameters of the whole-blood quality control materials.The correlation coefficients (r2) respectively between the three analyzers were all higher than 0.95 when used to test the 50 specimens.At all medical decision levels XS-800i and XS-1000i hematology analyzers both gained acceptable detection results except XS-800i hematology analyzer in case of 5.9×1012/L RBC count as well as 35% or 50% HCT.Conclusion Sysmex XS-800i,XS-1000i and XE-2100D hematology analyzers have high precisions and correlations when used to detect RBC count,HGB,HCT and MCV,and contrast test is suggested to be executed periodically to ensure the comparability of tbe result.
3.Personality traits analysis of medication overused migraine
Kuiyun WANG ; Shihua HUANG ; Rongmei LI ; Weigang KONG
Chongqing Medicine 2018;47(10):1340-1342
Objective To explore the personality characteristics of patients with chronic migraine complicating drugs overuse.Methods A total of 67 cases of migraine (control group) and 175 cases of medication overused migraine (MOH) were treated in the neurology department of this hospital from March to December 2016.The patients conformed to the migraine diagnostic criteria of the International Classification of Headache Disorders Third Edition (ICHD-3) formulated by the International Headache Society.The personality assessment adopted an internationally used Minnesota Personality Questionnaire.Results The scores of suspected disease,depression,rickets and social introgression in the observation group were higher than those in the control group,the difference was statistically significant (P<0.05).In the observation group,there was a negative correlation between personality suspicion,rickets,neurasthenia,social introversion and education (P< 0.05).In the personality traits aspect of the observation group,hypochondriasis,hysteria,neuradynamia and social introversion were negatively correlated with the cultural degree (P<0.05).Conclusion The personality changes in the four aspects of hypochondria,depression,hysteria and social introversion in the patients with MOH are more obvious than those in the patients with simple chronic migraine.