1.Safety of teriflunomide in Chinese adult patients with relapsing multiple sclerosis: A phase IV, 24-week multicenter study.
Chao QUAN ; Hongyu ZHOU ; Huan YANG ; Zheng JIAO ; Meini ZHANG ; Baorong ZHANG ; Guojun TAN ; Bitao BU ; Tao JIN ; Chunyang LI ; Qun XUE ; Huiqing DONG ; Fudong SHI ; Xinyue QIN ; Xinghu ZHANG ; Feng GAO ; Hua ZHANG ; Jiawei WANG ; Xueqiang HU ; Yueting CHEN ; Jue LIU ; Wei QIU
Chinese Medical Journal 2025;138(4):452-458
BACKGROUND:
Disease-modifying therapies have been approved for the treatment of relapsing multiple sclerosis (RMS). The present study aims to examine the safety of teriflunomide in Chinese patients with RMS.
METHODS:
This non-randomized, multi-center, 24-week, prospective study enrolled RMS patients with variant (c.421C>A) or wild type ABCG2 who received once-daily oral teriflunomide 14 mg. The primary endpoint was the relationship between ABCG2 polymorphisms and teriflunomide exposure over 24 weeks. Safety was assessed over the 24-week treatment with teriflunomide.
RESULTS:
Eighty-two patients were assigned to variant ( n = 42) and wild type groups ( n = 40), respectively. Geometric mean and geometric standard deviation (SD) of pre-dose concentration (variant, 54.9 [38.0] μg/mL; wild type, 49.1 [32.0] μg/mL) and area under plasma concentration-time curve over a dosing interval (AUC tau ) (variant, 1731.3 [769.0] μg∙h/mL; wild type, 1564.5 [1053.0] μg∙h/mL) values at steady state were approximately similar between the two groups. Safety profile was similar and well tolerated across variant and wild type groups in terms of rates of treatment emergent adverse events (TEAE), treatment-related TEAE, grade ≥3 TEAE, and serious adverse events (AEs). No new specific safety concerns or deaths were reported in the study.
CONCLUSION:
ABCG2 polymorphisms did not affect the steady-state exposure of teriflunomide, suggesting a similar efficacy and safety profile between variant and wild type RMS patients.
REGISTRATION
NCT04410965, https://clinicaltrials.gov .
Humans
;
Crotonates/adverse effects*
;
Toluidines/adverse effects*
;
Nitriles
;
Hydroxybutyrates
;
Female
;
Male
;
Adult
;
ATP Binding Cassette Transporter, Subfamily G, Member 2/genetics*
;
Middle Aged
;
Multiple Sclerosis, Relapsing-Remitting/genetics*
;
Prospective Studies
;
Young Adult
;
Neoplasm Proteins/genetics*
;
East Asian People
2.Characterization and features of dampness-heat obstruction syndrome in rats with knee osteoarthritis based on "disease-syndrome-symptom" combination research strategy.
Li-Li WANG ; Teng-Teng XU ; Xiao-Xiao WANG ; Qun LI ; Li-Ting XU ; Wei-Heng CHEN ; Chun-Fang LIU ; Na LIN
China Journal of Chinese Materia Medica 2025;50(7):1861-1871
A combination of the "disease-syndrome-symptom" approach was used to study the syndrome characterization and features of dampness-heat obstruction syndrome in papain-induced knee osteoarthritis(KOA) model rats during the disease process. Forty-eight male SD rats were randomly divided into sham and model groups. The KOA model was established by injecting a mixture of papain and L-cysteine into the joint cavity on days 1, 3, and 5. During the 8 weeks following model establishment, the rats were assessed weekly for the plantar mechanical pain threshold, knee joint diameter, local skin temperature of the knee joint, weight-bearing difference between the two hind feet, and the modified Lequesne MG score of the knee joint. Samples were collected at 1, 2, 4, 6, and 8 weeks after model establishment to observe the gross lesions in cartilage and synovium. Histopathological changes in joint tissues were examined using hematoxylin-eosin, Masson's trichrome, and Senna red O-solid green staining. ELISA and immunohistochemical analysis were performed to detect the levels of interleukin(IL)-1β, IL-6, tumor necrosis factor(TNF)-α, prostaglandin E2(PGE2), and the expression of aquaporins(AQP) 1 and 3 in serum and synovium. The results showed that the ink score of articular cartilage in the model group significantly increased from 4 to 8 weeks, the cartilage Mankin's score and the percentage of Masson-positive area in cartilage increased significantly from 1 to 8 weeks. The percentage of red-stained area for cartilage proteoglycans decreased significantly from 1 to 8 weeks. The synovitis score from 1 to 6 weeks and the percentage of blue-stained collagen fibers in the synovium from 1 to 8 weeks increased significantly, with statistically significant differences compared to the sham group. The mechanical pain threshold in the model group significantly decreased from 1 to 8 weeks, the knee joint diameter significantly increased from 1 to 6 weeks, and the local skin temperature of the knee joint, the weight-bearing difference between the two hind feet, and the modified Lequesne MG score from 1 to 5 weeks significantly increased, all with statistically significant differences compared to the sham group. The levels of IL-1β, IL-6, TNF-α, and PGE2 in serum and synovium of the model group significantly increased from 1 to 6 weeks. Serum TNF-α and PGE2, and synovial IL-1β, also significantly increased at 8 weeks. The levels of cartilage AQP1 and AQP3 significantly increased from 1 to 4 weeks, while synovial AQP1 and AQP3 increased significantly from 1 to 6 weeks, with all differences statistically significant compared to the sham group. In conclusion, papain-induced KOA rats exhibited pathological changes, including articular cartilage degeneration and synovial inflammation, within 1 week of induction. The KOA rats showed characteristics of dampness-heat obstruction syndrome, such as joint pain, swelling, elevated skin temperature, and decreased function, as well as increased inflammatory factors and AQP1、AQP3 in serum and joint tissues within 5 to 6 weeks of disease onset. These results provide an experimental model for studying the syndromes of KOA with dampness-heat obstruction syndrome.
Animals
;
Male
;
Rats, Sprague-Dawley
;
Rats
;
Osteoarthritis, Knee/physiopathology*
;
Disease Models, Animal
;
Humans
;
Interleukin-1beta/metabolism*
;
Interleukin-6/metabolism*
;
Tumor Necrosis Factor-alpha/metabolism*
;
Knee Joint/pathology*
4.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
5.The potential therapeutic role of ginsenosides on fibrosis-associated diseases: a review on molecular mechanisms and call for further research.
Mengguang WEI ; Yue ZHANG ; Xiaomeng SUN ; Lianwen QI ; Qun LIU
Chinese Journal of Natural Medicines (English Ed.) 2025;23(6):673-686
Fibrosis is characterized as an aberrant reparative process involving the direct replacement of damaged or deceased cells with connective tissue, leading to progressive architectural remodeling across various tissues and organs. This condition imposes a substantial burden, resulting in considerable morbidity and mortality. Ginseng (Panax ginseng C. A. Meyer), renowned for its medicinal properties, has been incorporated as a key component in Chinese patent medicines to mitigate fibrotic diseases. Ginsenosides, the primary bioactive compounds in ginseng, have garnered significant attention. Over the past five years, extensive research has explored the pharmaceutical potential of ginsenosides in diverse organ fibrosis conditions, including liver, myocardial, renal, and pulmonary fibrosis. Studies have elucidated that ginsenosides demonstrate potential effects on inflammatory responses stemming from parenchymal cell damage, myofibroblast activation leading to extracellular matrix (ECM) production, and myofibroblast apoptosis or inactivation. Additionally, potential downstream targets and pathways associated with these pathological processes have been identified as being influenced by ginsenosides. This review presents a comprehensive overview of the efficacious treatments utilizing ginsenosides for various tissue fibrosis types and their potential anti-fibrotic mechanisms. Furthermore, it offers a reference for the development of novel candidate drugs for future organ fibrosis therapies.
Ginsenosides/pharmacology*
;
Humans
;
Fibrosis/drug therapy*
;
Animals
;
Panax/chemistry*
;
Drugs, Chinese Herbal/therapeutic use*
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail