1.Elucidation of the national standard for Standard ized Manipulation of Acupuncture and Moxibustion, Part VII: Skin needle.
Hua WANG ; Xu-Ping WU ; Wei HUANG
Chinese Acupuncture & Moxibustion 2011;31(7):659-660
Acupuncture Therapy
;
instrumentation
;
methods
;
standards
;
China
;
Humans
;
Moxibustion
;
instrumentation
;
methods
;
standards
;
Needles
;
standards
;
Reference Standards
2.Use of PEI-coated magnetic iron oxide nanoparticles as gene vectors.
Weizhong, WEI ; Chunfang, XU ; Hua, WU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2004;24(6):618-20
To evaluate the feasibility of using polyethyleneimine (PEI) coated magnetic iron.oxide nanoparticles (polyMAG-1000) as gene vectors. The surface characteristics of the nanoparticles were observed with scanning electron microscopy. The ability of the nanoparticles to combine with and protect DNA was investigated at different PH values after polyMAG-1000 and DNA were combined in different ratios. The nanoparticles were tested as gene vectors with in vitro transfection models. Under the scanning electron microscope the nanoparticles were about 100 nm in diameter. The nanoparticles could bind and condense DNA under acid, neutral and alkaline conditions, and they could transfer genes into cells and express green fluorescent proteins (GFP). The transfection efficiency was highest (51%) when the ratio of nanoparticles to DNA was 1:1 (v:w). In that ratio, the difference in transfection efficiency was marked depending on whether a magnetic field was present or not: about 10% when it was absent but 51% when it was present. The magnetic iron oxide nanoparticles coated with PEI may potentially be used as gene vectors.
Breast Neoplasms/metabolism
;
Breast Neoplasms/*pathology
;
Cell Line, Tumor
;
Ferric Compounds/*chemistry
;
Ferric Compounds/metabolism
;
Gene Targeting
;
Genetic Vectors
;
Green Fluorescent Proteins
;
Magnetics
;
Nanotechnology
;
Particle Size
;
Polyethyleneimine/chemistry
;
Transfection/methods
3.Magnetic iron oxide nanoparticles mediated gene therapy for breast cancer--an in vitro study.
Weizhong, WEI ; Chunfang, XU ; Hua, WU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2006;26(6):728-30
The aim of this study was to evaluate the feasibility and efficacy of using TRAIL gene to treat breast cancer mediated with a novel carrier - magnetic iron oxide nanoparticles (poly-MAG-1000) coated with PEI. The magnetic iron oxide nanoparticles were used as gene carrier to transfect TRAIL gene into MCF-7 cells. The polyMAG-1000 without TRAIL gene was transfected into the tumor cells as negative control. TRAIL gene transfection with liposome as carrier served as positive control. The apoptosis of cells was detected with TUNEL method. The apoptosis ratio of tumor cells was measured with flow cytometry (FCM). It was found that the apoptosis occurred in the tumor cells after transfection of TRAIL gene mediated by both polyMAG-1000 and liposome. The apoptosis ratio in the group with polyMAG-1000 as gene carrier was (25.11+/-2.85) %, whereas it was (5.06+/- 1.05) % in the control group with polyMAG-1000 (P<0.01). The apoptosis ratio was as low as (18.31+/-2.44) % in the group with liposome as gene carrier (P<0.05, as compared with the group with polyMAG-1000 as gene carrier). It is suggested that TRAIL gene may induce apoptosis in MCF-7 breast cancer cells. The magnetic iron oxide nanoparticles coated with PEI may be a potential gene carrier with high transfection efficacy for cancer gene therapy..
4.An experimental study of PEI coated magnetic iron oxide nanoparticles as gene vectors
Weizhong WEI ; Hua WU ; Chunfan XU
Journal of Medical Postgraduates 2003;0(04):-
Objective:To evaluate the feasibility of using polyethyleneimine(PEI) coated magnetic iron oxide nanoparticles(polyMAG-1000) as gene vectors. Methods:The surface characteristies of the nanoparticles were observed with scan electronical microscope.The ability of the nanoparticles to combine and protect DNA were investigated at different PH after the polyMAG-1000 and DNA were combined at different ratio.The nanoparticles were tested as a gene vectors through transfection models in vitro. Results: Under scan electronical microscope, the diameter of the nanoparticles was about 100 nm. The nanoparticles could bind and condense DNA under acidic ,neutral and alkaline pH conditions. The nanoparticles could transfer gene into cell and express green fluorescent protein(GFP).The efficiency of transfection was the highest when the ratio of the nanoparticles and DNA was 1 ∶ 1(v ∶ w).The difference was marked in the transfection efficiency when magnetic field was added or not. Conclusion: The magnetic iron oxide nanoparticles coated with PEI may be potentially used as gene vectors.
5.A Study on the Relationship Between the Abnormal Expression of TGF-?_1, TGF-?RⅠand Malignant Biological Behaviors in Ovarian Carcinoma
Yuzhen GUO ; Hua XU ; Wei MA
Journal of Chinese Physician 2001;0(02):-
Objective To investigate the expression and significance of transforming growth factor-beta1(TGF-? 1),transforming growth factor-beta receptor typeⅠ(TGF-? RⅠ) in human ovarian carcinoma. Methods Inmmunohistochemical SP method was used to detect the expression of TGF-? 1 and TGF-? RI in 85 cases of benign and malignant ovarian tumors. Results The positive rate of TGF-? 1 in benign and malignant ovarian tumors was significantly higher than that in the normal ovarian tissues(P
6.Evaluation on cardiac index measured with arterial pressure-based cardiac output and pulmonary artery catheter during cesarean section in parturients with congenital heart disease combined with severe pulmonary hypertension
Zhiwei MO ; Hua WEI ; Kangqing XU
Chinese Journal of Postgraduates of Medicine 2014;37(35):41-44
Objective To evaluate the concordance on cardiac index (CI) measured with arterial pressure based cardiac output (APCO) and pulmonary artery catheter (PAC) during cesarean section in parturients with congenital heart disease combined with severe pulmonary hypertension.Methods Forty-five congenital heart disease combined with severe pulmonary hypertension parturient who scheduled for cesarean section were selected,APCO and PAC were used for cardiac output and other parameters of hemodynamics monitoring during operation in all patients.Continuous epidural anesthesia was performed.CI was recorded immediately before epidural administration (T1),at 5 and 10 min after epidural administration (T2,T3),immediately before delivery (T4),and at 2 and 5 min after delivery (T5,T6).The correlation of CI between APCO and PAC (A-CI and P-CI,respectively) was tested by Pearson correlation analysis and agreement test.Results The P-CI was significantly higher than A-CI,there was statistical difference (P < 0.05).Compared with T1,no significant differences between A-CI and P-CI were found at T2-T4 and T6 (P > 0.05),The A-CI at T5 [(4.5 ± 1.1) L/(min·m2) vs.(4.2 ± 0.8) L/(min ·m2)] and P-CI [(6.2 ± 1.5) L/(min·m2) vs.(5.4 ± 1.2) L/ (min· m2)] were significantly higher,there were statistical differences (P < 0.05).The correlation analysis showed that there was positive correlation between A-CI and P-CI at T1-6 (r =0.931,0.955,0.945,0.892,0.960,0.913 ; P < 0.05).Bland-Altman analysis showed poor agreement between CI measured with the two methods.Conclusion CI value obtained with APCO agrees poorly with that obtained with PAC during cesarean section in parents with congenital heart disease combined with severe pulmonary hypertension,but agrees well in monitoring the changing trend of CI.
8.Development of a Medication Compliance Scale in Patients with Chronic Diseases
Wei-Hua XU ; Qi WANG ; Wei-Xiong LIANG
Chinese Journal of Prevention and Control of Chronic Diseases 2006;0(06):-
Objective To develop a reliable scale for evaluating medication compliance among patients with chronic diseases in China.Methods An initial item pool was generated by literature review,based on the definition of compliance generally accepted in China.The items were then subjected to item selections by using item answer distribution and other four methods,which resulted in a primary scale with 16 items.The reliability and validity of this scale was examined.Results Common factors extracted by factor analysis were well explained,there being a close correspondence between the scale construction and the theoretical construction. Convergent validity with the patients' self-ratings on medication compliance ranged from 0.55 to 0.59,and the correlation coefficient with the score of Morisky questionnaire was 0.58.The Cronbach ?,0 and ? coefficients were 0.717,0.751,0.893 respectively,and test-retest reliability was 0.95.Conclusion The newly developed scale appears reliable and may be a useful tool for measuring drug compliance among patients with chronic diseases,but there are still areas where further improvements may be needed.
9.Comparison of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer
Wei, QIU ; Yanjun, HUA ; Zequan, XU ; Qiang, WU
Chinese Journal of Experimental Ophthalmology 2017;35(6):544-547
Background The measurement of corneal Q value is essential for corneal refractive surgery and calculation of intraocular lens during cataract surgery.Topolyzer was often used for the measurement of Q value,and recently Topcon KR-1W and iTrace were applied in ophthalmology.However,whether the measured values are interchangeable is unclear.Objective This study was to assess the difference and consistency of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer.Methods Corneal Q values were measured on 100 right eyes of 100 healthy subjects under the approval of Ethic Committee of the Sixth Hospital Affiliated to Shanghai Jiaotong University and informed consent of each subject from November to December in 2014 with Topcon KR-1W,iTrace and Topolyzer.Three valid measurements were obtained for each device,and the average values from each device were calculated.The difference of the outcomes among the instruments was compared by repeated measures analysis of variance (ANOVA),and the consistency among the outcomes from different apparatus was analyzed by Bland-Altman plots.Results The mean corneal Q values were-0.184-±0.112,-0.117±0.167 and-0.269±0.117 from Topcon KR-1W,iTrace and Topolyzer,respectively,with a significant difference among them (P < 0.001).The measured Q value by Topcon KR-1W was 0.085±0.010 larger than that by Topolyzer,and the Q values by iTrace was 0.152± 0.014 larger than that by Topolyzer,while the Q values obtained by Topcon KR-1W was 0.067±0.016 smaller than that by iTrace (all at P<0.05).The 95% confidence interval of the values between Topcon KR-1W and iTrace,Topcon KR-1W and Topolyzer,iTrace and Topolyzer were-0.106 to-0.028,0.060 to 0.109 and 0.118 to 0.186,respectively.Bland-Altman plots showed that 6%,6% and 5% values were outside of 95% agreement of limit (LoA) between Topcon KR-1W and iTrace,iTrace and Topolyzer or KR-1W and Topolyzer,respectively,with the maximal differences of 0.28,0.43 and 0.38.Conclusions Corneal Q values measured by Topcon KR-1W and iTrace are larger than those measured by Topolyzer.Due to the poor agreements among the corneal Q values by the 3 kinds of devices,they are not interchangeable in clinical applications for the measurement of corneal Q value.
10.ALK-positive primary anaplastic large-cell lymphoma of stomach: report of a case.
Wei-hua WU ; Hong-ying CAO ; Zhen XU
Chinese Journal of Pathology 2011;40(3):197-198
Adult
;
Diagnosis, Differential
;
Female
;
Gastrectomy
;
methods
;
Gastrointestinal Stromal Tumors
;
metabolism
;
pathology
;
Humans
;
Ki-1 Antigen
;
metabolism
;
Leukocyte Common Antigens
;
metabolism
;
Leukosialin
;
metabolism
;
Lymphoma, Large-Cell, Anaplastic
;
metabolism
;
pathology
;
surgery
;
Melanoma
;
metabolism
;
pathology
;
Mucin-1
;
metabolism
;
Receptor Protein-Tyrosine Kinases
;
metabolism
;
Stomach Neoplasms
;
metabolism
;
pathology
;
surgery