1.Clinical analysis of 68 patients with invasive pulmonary fungal infection
Jun SUN ; Jun WEI ; Xuefen SHUI
Clinical Medicine of China 2011;27(9):940-942
ObjectiveTo investigate the clinical features and high risk factors of invasive pulmonary fungalinfection(IPFI) to facilitate its diagnosis and treatment.MethodsA retrospective investigation on the clinical data from 68 cases of IPFI patients in our hospital's data banks between Jan.2007 and Mar.2011 was performed.ResultsThe average age of 68 patients was 61 years old.Candida albiacns(36 cases ,52.94%)was the major pathogen for the infection, and the next was aspergillus species(18 cases, 26.47%) and then cryptococcus species(10 cases, 14.71%) .For the primary IPFI,cryptococcus species was the first cause of infection.The main risk factors included severe underlying disease, long-term joint use of antibiotics as well as glucocorticoid usage.Fourty-seven of the 68 cases were cured or improved, 7 were unimproved and 14 died.Conclusion Effective measures to reduce the morbidity and mortality include positive supportive care,curing underlying disease, avoiding invasive surgical procedures and timely and reasonable antibiotics, antifungal and glucocorticoid drugs.
2.Treatment of severe knee deformity using Endo-Model rotating-hinge prosthesis
Shuai WU ; Shui SUN ; Wei ZHANG
Orthopedic Journal of China 2006;0(05):-
[Objective]To study the clinical result of Endo-Model rotating-hinge prosthesis in the treatment of severe knee deformity. [Method]Twenty-two patients(10 males and 12 females;12 right knees,8 left knees,and 2 bilateral knees) were selected for total knee arthorplasty using Endo-Model rotating-hinge prosthesis.The average age was 56.2 years.All the patients were evaluated by HSS score system.[Result]All incisions healed at one-stage and all malformations were corrected.The functional result was good.Mile deep vein thrombosis was found in one case after operation.All the patients were followed up for 6-55 months.No infection or prosthetic loosening was developed.[Conclusion]Endo-Model rotating-hinge prosthesis is an effective and reliable prosthesis for severe knee deformity.
3.Primary total hip arthroplasty using the modular S-ROM prosthesis for the treatment of severe developmental dysplasia of the hip
Xitao SUN ; Shui SUN ; Wei ZHANG
Orthopedic Journal of China 2006;0(06):-
[Objective]To research short-term results of primary total hip arthroplasty using the cementless modular S-ROM prosthesis for the treatment of severe developmental dysplasia of the hip.[Method]Eighten patients(19 hips) with severe developmental dysplasia of the hip underwent primary total hip arthroplasty using the S-ROM prosthesis.Of the patients,6 were male and 12 were female.The average age was 32 years.According to the Crowe classification system,there were 11 hips in type Ⅲ and 8 hips in type Ⅳ.The acetabulums were deepened at the level of the true acetabulum.The S-ROM modular stems were used on the femoral side.Subtrochanteric shortening osteotomy was performed when it was difficult to reset.The Harris hip score(HHS) and radiography were used to evaluate the hip function preoperatively and at the follow-up.[Result]One proximal femur tissure fracture occurred,and was bundled up with circle wire.There were 2 postoperative sciatic nerve irritation,which disappeared completely within 3 months.All patients were available for follow-up.There was one heterotopic ossification above greater trochanter.But the mobility of the hip was normal.There was no loosening or infection during the follow-up.Average follow-up period was(2.8) years(range,6 months-5 years).The HHS increased from 38.4 preoperatively to 85.2 at the time of final follow-up.[Conclusion]S-ROM is a perfect choice for the teatment of severe developmental dysplasia of the hip.Short-time clinical results were excellent.
4.Arthroscopie reconstruction of anterior cruciate ligament using RIGIDfix and Intrafix system with quadruple-strand hamstring tendons
Xianquan WANG ; Wei ZHANG ; Shui SUN
Orthopedic Journal of China 2006;0(06):-
[Objective] To study the effect of arthroscopic reconstruction of anterior cruciate ligament using RIGIDfix and Intraflx system with quadruple-strand hamstring tendons.[Method]Thirty-six cases of anterior cruciate ligament ruptures were reconstructed arthroscopically with four strands of hamstring tendons,and the grafts were fixed with RIGIDfix and Intrafix system.Ptients were treated with systematic rehabilitation therapy and relevant complications were managed post-operatively.The patients were followed up for 6~12 months,ask the patients' subjective symptom,examine the knee range of motion,anterior drawer test,Lachman test and Pivot shift test,were managed to evaluate clinical result according to Lysholm rating.[Result]All patients had no serious complication,and were followed up for 6~12 months post-operatively.All patients had returned his post,knee range of flexion achieved 130?,extention achieved 0?.Three cases sometimes felt his knee soft and instabilization during exercise violently,the other patients had no sensation of soft and instabilization.When patients were followed up,anterior drawer test:negative 35 cases,positive 1 case;Lachman test:negative 33 cases,positive 3 cases;Pivot shift test of all patients were negative.The Lysholm score increased from 51.3?4.2 to 85.6?4.6,the difference was significant(P
5.A Optional Staining Method for the Hyphae’s Nuclear of Pleurotus tuber-region
Rong-Tong LI ; Guang-Lu GONG ; Lian-Shui CHEN ; Shui-Ming BAO ; Wei DU ;
Microbiology 2008;0(08):-
We have obtain a steady and reliable dyeing methods for the uniuncleate and dicaryotic hyphae of Pleurotus tuber-regium by using different foster hyphae way, comparing two kinds of fastness liquid and three dye stuff on the hyphae nuclear stain effect, and then optimization grouping.
6.Effect of selective laser trabecularplasty on early chronic primary angle-closure glaucoma
ming-shui, FU ; da-wei, LUO ; min, TANG ; ying, MA
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(06):-
21 mmHg.The side effects,IOP and application of anti-glaucoma drugs were examined 1 h,1 d,1 week,1 month,3 months and 6 months after SLT. Results The IOP was significantly decreased 1 week,1 month,3 months and 6 months after SLT compared with that before treatment(P21 mmHg using two anti-glaucoma drugs,respectively. Conclusion SLT is a safe and effective method for IOP control in early CPACG after treatment with laser peripheral iridoplasty and laser iridectomy.
7.Needling revision with mitomycin C subconjuctival injection on early failed filtering blebs
ming-shui, FU ; ying, MA ; min, TANG ; da-wei, LUO
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(06):-
Objective To evaluate the therapeutic effects of needling revision with mitomycin C(MMC) subconjuctival injection on early failed filtering blebs after trabeculectomy for glaucoma. Methods Needling revision with MMC 0.2 mL(0.04 mg) subconjuctival injection was performed on 86 eyes of 76 patients with failed filtering blebs 2 to 6 weeks after trabeculectomy for glaucoma.An average of 1.88 times of treatment was performed.The intraocular pressure(IOP),blebs and side effects were observed,and follow-up was conducted for 6 months. Results Two to six weeks after trabeculectomy,there were 50 eyes with thickened and focalized blebs,32 eyes with encapsulated blebs and 4 eyes with no bleb.Six months after needling revision with MMC subconjuctival injection,blebs of 61 eyes turned into functional ones.The blebs were thinned and multicysted in 24 eyes,diffused and elevated in 37 eyes,thickened and focalized in 6 eyes,encapsulated in 13 eyes and disappeared in 6 eyes.Three months after treatment,the mean IOP was(15.2?6.1) mmHg,and there were 57 eyes with IOP
8.Analysis of 130 forensic expertise cases of simple orbital fracture.
Wei HUANG ; Cheng-Ren ZHU ; Hong HUANG ; Mei-Shui TAO
Journal of Forensic Medicine 2014;30(5):357-359
OBJECTIVE:
To analyze the features of orbital fracture and to discuss its forensic expertise points.
METHODS:
One hundred and thirty cases of simple orbital fracture from 2010 to 2012 collected from one public security bureau were retrospectively analyzed such as age, gender, tools, position and morphology of the fracture, periorbital and orbital compound injury and the follow-up results after 6 months.
RESULTS:
In the 130 cases, the wounded were mainly young men and hit by fist. The fracture of simple medial orbital wall accounted for up to 81.5% in all cases. In the periorbital and orbital compound injury, laceration and contusion of eyelid and ethmoidal cellules and maxillary sinus always occurred. After 6 months follow-up, there were 30 cases of comminuted fracture remained enophthalmos compared with the uninjured side.
CONCLUSION
It is inappropriate to judge the fracture of simple medial orbital wall as minor injury. We should judge the degree of simple orbital fracture after the injury is stable. Detailed ophthalmology inspection is necessary for forensic expertise of simple orbital fracture.
Craniocerebral Trauma
;
Enophthalmos
;
Female
;
Fractures, Comminuted/pathology*
;
Humans
;
Male
;
Ophthalmologic Surgical Procedures
;
Orbit
;
Orbital Fractures/surgery*
;
Retrospective Studies
;
Severity of Illness Index
;
Trauma Severity Indices
9.Comparison of efficacies of two fixation methods in treatment of complex intra-articular fracture of the distal radius
Naiqiang ZHUO ; Jianhua GE ; Wei SHUI ; Zhengjiang LI ; Xiaobo LU
Chinese Journal of Trauma 2009;25(8):717-720
Objective To compare the efficacies and indications of locking compression plate (LCP) and external fixator plus Kirschner wires in treatment of complex intra-articular fracture of the dis-tal radius. Methods Ninety-eight patients with complex intra-articular fractures of the distal radius were treated with volar LCP or external fixator plus Kirschner wires, the efficacies of which were evaluated by comparing the grasping force and wrist function of the patients. Results All the patients were fol-lowed up for an average of 12.4 months, which showed fracture healing in all the patients. According to the wrist function assessment system of New York Orthopedic Hospital (1990), there was no statistical difference in the efficacy of LCP and external f'lxator plus Kirschner wires in treatment of types C1 or C2 fractures (P > 0.05), while the efficacy of external fixator plus Kirschner wires was significantly superior to that of LCP in treating type C3 fracture (P < 0.05). Conclusions For types C1 or C2 intra-articu-lar fractures of the distal radius, the efficacies of LCP and external fixator plus Kirschner wires are simi-lar, while the efficacy of external fixator plus Kirschner wires is superior to that of LCP in treating type C3 intra-articular fracture of the distal radius.
10.Treatment of knee arthropathy with rotating-platform knee prosthesis in 62 cases
Bin LI ; Wei ZHANG ; Shui SUN ; Huazheng QU ; Xitao SUN
Chinese Journal of Tissue Engineering Research 2009;13(48):9575-9578
OBJECTIVE: To study the therapeutic effect of treating knee arthropathy with total knee arthroplasty using rotating-platform knee prosthesis. METHODS: A total of 62 patients (74 knees) in Provincial Hospital Affiliated To Shandong University from January 2005 to January 2009 were selected, including 36 males (41 knees) and 26 females (33 knees), aged 52-79 years, mean aged 61.5 years; 28 cases with left knee, 22 cases with right knee and 12 cases of both knees. The cases were composed of 34 cases with osteoarthritis, 21 cases with rheumatoid arthritis and 7 cases with traumatic arthritis. All the patients received the total knee arthroplasty for the first time using rotating-platform knee prosthesis, no replacement of the patella. The clinical results of pre-operetion and after-operation were evaluated by the HSS knee rating score system. RESULTS: All the patients were followed-up for averaged 22 months (3-48 months) after operation. Incisions of all the cases were healed, and there was no infection and hematoma. Lower extremity deep venous thrombosis occurred in 2 cases at 3 days after operation. Swelling disappeared through drug treatment 10 days later. Pain and function of all the patients were obviously ameliorated after operation. The average HSS knee rating score was 44.99 (from 34 to 58) before total knee arthroplasty, which was improved to 88.78 (from 69 to 98), and the good-to-excellent rate was 98% (excellent 45 cases, good 16 cases, average 1 case). There were no signs of prosthetic dislocation or loosening in the X-ray films. CONCLUSION: Total knee arthroplasty using rotating-platform knee prosthesis owns advantages of easy surgical operation, tess complications, good recovery and satisfactory results in a short-term.