1.Outbreak of novel influenza A (H1N1-2009) linked to a dance club.
Pei Pei CHAN ; Hariharan SUBRAMONY ; Florence Y L LAI ; Wee Siong TIEN ; Boon Hian TAN ; Suhana SOLHAN ; Hwi Kwang HAN ; Bok Huay FOONG ; Lyn JAMES ; Peng Lim OOI
Annals of the Academy of Medicine, Singapore 2010;39(4):299-294
INTRODUCTIONThis paper describes the epidemiology and control of a community outbreak of novel influenza A (H1N1-2009) originating from a dance club in Singapore between June and July 2009.
MATERIALS AND METHODSCases of novel influenza A (H1N1-2009) were confirmed using in-house probe-based real-time polymerase chain reaction (PCR). Contact tracing teams from the Singapore Ministry of Health obtained epidemiological information from all cases via telephone.
RESULTSA total of 48 cases were identified in this outbreak, of which 36 (75%) cases were patrons and dance club staff, and 12 (25%) cases were household members and social contacts. Mathematical modelling showed that this outbreak had a reproductive number of 1.9 to 2.1, which was similar to values calculated from outbreaks in naïve populations in other countries.
CONCLUSIONThis transmission risk occurred within an enclosed space with patrons engaged in intimate social activities, suggesting that dance clubs are places conducive for the spread of the virus.
Adolescent ; Adult ; Commerce ; Contact Tracing ; methods ; Dancing ; Disease Outbreaks ; Female ; Humans ; Influenza A Virus, H1N1 Subtype ; isolation & purification ; Influenza, Human ; diagnosis ; epidemiology ; Interviews as Topic ; Male ; Models, Statistical ; Polymerase Chain Reaction ; Singapore ; epidemiology ; Travel ; Young Adult
2.Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.
Tien Siang Eric LIM ; Boon Yew TAN ; Kah Leng HO ; Chuh Yih Paul LIM ; Wee Siong TEO ; Chi-Keong CHING
Singapore medical journal 2015;56(10):580-585
Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.
Adult
;
Death, Sudden, Cardiac
;
prevention & control
;
Defibrillators, Implantable
;
statistics & numerical data
;
Electrophysiology
;
Follow-Up Studies
;
Humans
;
Male
;
Middle Aged
;
Patient Safety
;
Prosthesis Implantation
;
Singapore
;
Tachycardia, Ventricular
;
Ventricular Fibrillation
3.Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.
Paul Chun Yih LIM ; Audry Shan Yin LEE ; Kelvin Chi Ming CHUA ; Eric Tien Siang LIM ; Daniel Thuan Tee CHONG ; Boon Yew TAN ; Kah Leng HO ; Wee Siong TEO ; Chi Keong CHING
Singapore medical journal 2016;57(7):372-377
INTRODUCTIONRemote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network.
METHODSPatients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians.
RESULTSA total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported.
CONCLUSIONRemote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life.
Aged ; Arrhythmias, Cardiac ; diagnosis ; Defibrillators, Implantable ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Monitoring, Physiologic ; methods ; Pacemaker, Artificial ; Patient Safety ; Pilot Projects ; Prospective Studies ; Quality of Life ; Remote Consultation ; methods ; Singapore ; Surveys and Questionnaires