1.Study on the application of different-length peripheral intravenous catheters in patients undergoing metabolic and bariatric surgery:a randomized clinical trial
Xiaohui YANG ; Chang LIU ; Weihua YU ; Jionghuang CHEN ; Wanting SHENG ; Xiuzhu CAO ; Xufen ZENG ; Xianghong JIN ; Linfang ZHAO
Chinese Journal of Nursing 2024;59(4):401-407
Objective To investigate the appropriate venous access for obese patients undergoing metabolic and bariatric surgery by comparing the clinical outcomes of different lengths of peripheral intravenous catheters.Methods Inpatients who underwent bariatric surgery in a tertiary hospital in Zhejiang from August 2022 to December 2022 were selected as the study population using a fixed-point continuous convenience sampling method.A stratified block randomisation method was used to divide the group into an experimental group 1(mini-midline catheters),an experimental group 2(midline catheters)and a control group(short peripheral intravenous catheters,Short PIVCs).The incidence of catheter-related complications,the rate of extubation due to complications,the duration of catheter retention,the time to first catheter-related complication were compared in the 3 groups.Results A total of 186 patients were included,with 62 patients in each group.The overall incidence of catheter-related complications in experimental group 1,experimental group 2,and control group were 25.81%,8.06%,and 58.06%.The extubation rates due to complications were 19.35%,4.84%,and 41.94%,and the duration of catheter retention was 7.00(6.00,7.00)d,7.00(6.00,7.00)d,6.00(3.00,6.25)d.The differences were statistically different(P<0.05)when comparing the 3 groups.Among them,the differences in the overall incidence of catheter-related complications and the rate of extubation due to complications were statistically significant when comparing experimental group 1 with the control group,experimental group 2 with the control group,and experimental group 1 with experimental group 2(P<0.017);the duration of catheter retention in both experimental group 1 and experimental group 2 were higher than it in the control group,and the differences were statistically different(P<0.017).Conclusion The complication rate of mini-midline catheters and midline catheters is lower than that of short ones,and the indwelling time is consistent with the perioperative period of metabolic and bariatric surgery,which is suitable for use in patients undergoing metabolic and bariatric surgery.
2.Determination of metabolites of styrene in urine by dispersive liquid-liquid microextraction coupled with high performance liquid chromatography
Yingying GU ; Yong MEI ; Menghan NIE ; Xuguang SHENG ; Ruodan FANG ; Wanting SU ; Jun HAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2020;38(9):689-692
Objective:To establish a method for the determination of mandelic acid and phenylglyoxylic acid in the urine of styrene by dispersive liquid-liquid microextraction-high coupled with high performance liquid chromatography.Methods:N-octanol was used as an extractant and ethanol was used as a dispersing agent. The phenylglycolic acid and phenylglyoxylic acid in the urine were extracted, and the upper liquid was taken after vortexing and centrifuged, and then was injected into HPLC for analysis.Results:The linear correlation coefficient of the concentration of phenylglycolic acid in the range of 0~10.0 mg/L was greater than 0.999. The detection limit of the method was 9.9 μg/L, the recovery rates were 86.1%~101.6%. The intraday RSDs of the method were 1.07%~3.76%, and the interday RSDs were 1.24%~3.33%. The linear correlation coefficient of phenylglyoxylic acid in the range of 0.0~2.0 mg/L is greater than 0.999. The detection limit of the method was 2.6 μg/L, the recovery rates were 88.8%~100.3%. The intraday RSDs of the method were 1.02%~ 3.17%, and the interday RSDs were 1.59%~2.41%.Conclusion:The method has low detection limit, high enrichment ratio and good sensitivity, and is suitable for determination of phenylglycolic acid and phenylglyoxylic acid in urine of occupational exposure to styrene.
3.Determination of metabolites of styrene in urine by dispersive liquid-liquid microextraction coupled with high performance liquid chromatography
Yingying GU ; Yong MEI ; Menghan NIE ; Xuguang SHENG ; Ruodan FANG ; Wanting SU ; Jun HAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2020;38(9):689-692
Objective:To establish a method for the determination of mandelic acid and phenylglyoxylic acid in the urine of styrene by dispersive liquid-liquid microextraction-high coupled with high performance liquid chromatography.Methods:N-octanol was used as an extractant and ethanol was used as a dispersing agent. The phenylglycolic acid and phenylglyoxylic acid in the urine were extracted, and the upper liquid was taken after vortexing and centrifuged, and then was injected into HPLC for analysis.Results:The linear correlation coefficient of the concentration of phenylglycolic acid in the range of 0~10.0 mg/L was greater than 0.999. The detection limit of the method was 9.9 μg/L, the recovery rates were 86.1%~101.6%. The intraday RSDs of the method were 1.07%~3.76%, and the interday RSDs were 1.24%~3.33%. The linear correlation coefficient of phenylglyoxylic acid in the range of 0.0~2.0 mg/L is greater than 0.999. The detection limit of the method was 2.6 μg/L, the recovery rates were 88.8%~100.3%. The intraday RSDs of the method were 1.02%~ 3.17%, and the interday RSDs were 1.59%~2.41%.Conclusion:The method has low detection limit, high enrichment ratio and good sensitivity, and is suitable for determination of phenylglycolic acid and phenylglyoxylic acid in urine of occupational exposure to styrene.