1.Atlanto-Axial Osteoarthritis: Imaging Findings and Clinical Significance
Yunhua MAO ; Wanjiang YU ; Aide XU ; Xiaofeng GAO
Journal of Practical Radiology 1996;0(04):-
50 years) with occipitocervical pain.
2.Preliminary analysis of clinical images of SARS
Xiangke DU ; Wanjiang YU ; Silun WANG ; Qizhi ZHU ; Nan HONG
Chinese Journal of Radiology 2001;0(09):-
Objective To investigate the clinical thoracic images of SARS. Methods Thoracic images of SARS were analyzed in 175 patients with 1 060 chest plain films and 20 CT scans. Results The typical signs of SARS were multifocal air-space consolidations and progress over a day from small shadow to generalized findings. Conclusion It is necessary to make the diagnosis of SARS with thoracic plain film, and CT could detect the early pulmonary abnormality of SARS.
3.Efficacy comparison of small-incision lenticule extraction and femtosecond assisted laser in situ keratomileusis in the treatment of myopia with astigmatism
Min ZHOU ; Suying YU ; Wanjiang DONG ; Long CHEN ; Miao HE
International Eye Science 2025;25(2):292-296
AIM: To compare the efficacy of small-incision lenticule extraction(SMILE)and femtosecond assisted laser in situ keratomileusis(FS-LASIK)in the treatment of patients with myopia and astigmatism.METHODS: Retrospective analysis. A total of 100 cases(200 eyes)of patients with myopia and astigmatism treated in our hospital from December 2021 to December 2022 were collected. Among them, 50 cases(100 eyes)were divided into SMILE group and 50 cases(100 eyes)were divided into FS-LASIK group according to the treatment plans. The visual acuity and astigmatism, corneal morphology parameters, subjective visual quality scores, ocular surface indicators, postoperative complications, and quality of life were compared between the two groups before and after surgery.RESULTS: There was no significant difference in uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), astigmatism, corneal asphericity Q value, corneal surface regularity index(SRI), corneal thickness, and corneal curvature between the two groups before surgery and at 1 d, 1, and 6 mo after surgery(all P>0.05). At 1 and 6 mo after surgery, the subjective visual quality score, the quality of life score, Schirmer I test(SⅠt)and tear film break-up time(BUT)in the SMILE group were better than that in the FS-LASIK group(all P<0.05). The incidence of complications in the SMILE group was lower than that in the FS-LASIK group at 6 mo after surgery(P=0.005).CONCLUSION: Both SMILE and FS-LASIK have good clinical effects in the treatment of myopia with astigmatism, but the SMILE could alleviate ocular surface injury, reduce the risk of complications and improve the quality of lifes for patients.
4.Preliminary study on detecting drug-resistance mycobacterium tuberculosis by using DNA microarray hybridization
Wanjiang ZHANG ; Lang BAO ; Xiaoying WAN ; Huidong ZHANG ; Yongen XIE ; Wei CHEN ; Xianghua YU
Chinese Journal of Pathophysiology 1989;0(06):-
AIM:To detect the drug-resistance mycobacterium tuberculosis by using DNA microarray hybridization.METHODS: DNA microarray for detecting drug-resistance of mycobacterium tuberculosis was prepared; Clinical isolated strains were cultivated and their drug-resistance sensitivity was detected. The genome DNA of mycobacterium tuberculosis was prepared and the drug-resistance genes of the mycobacterium tuberculosis were amplified by PCR. Then the gene chip was hybridized, washed, detected and analyzed. RESULTS: Results of cultivating mycobacterium tuberculosis and detecting the drug-resistance sensitivity: one strain was drug-sensitive; four strains were multi-drug-resistant; The detecting results of the drug-resistance was consistent with the results of diagnosis therapy of the 5 clinical patients. The detecting results of gene chip confirmed the above facts. CONCLUSION: Detecting drug-resistance mycobacterium tuberculosis by the gene chip is precise, fast and highly-efficient.
5.Application value of " one-stop" scanning of coronary and head and neck CTA using low tube voltage
Wanjiang LI ; Jianqun YU ; Tao SHUAI ; Jia TAN ; Wanlin PENG ; Zixuan LIU ; Yao ZHU ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2019;39(1):11-15
Objective To investigate the value of "one-stop" scanning of coronary and head and neck CTA in patients with normal body mass index (18 kg/m2 ≤ BMI ≤ 25 kg/m2) using low tube voltage (80 kVp).Methods In a retrospective analysis 80 patients with normal body mass index who had completed "one-stop" scanning of coronary and head and neck CTA were divided into A and B groups according to different scanning method,and 40 consecutive cases were selected in each group.Scanning parameters of group A and group B were tube voltage 80 kV,coronary CTA tube current 550 mA,head and neck CTA tube current 500 mA,and tube voltage 100 kV,coronary CTA tube current 450 mA,head and neck CTA tube current 400 mA separately.Subjective evaluation and objective evaluation were performed on the image quality of the two groups.CT values of coronary artery and head and neck CTA trunk branch vessel,contrast-to-noise ratio (CNR),image noise (SD) and effective dose between the two groups were compared.Results The image quality of both groups met the diagnostic requirements,and there was no statistically significant difference in subjective scores between two groups (P>0.05).The CT values of coronary arteries,the main branches of the head and neck (the common carotid artery,the internal carotid artery) and SD of head and neck CTA were significantly different between two groups (t=4.737,6.552,3.359,2.165,2.685,4.617,P<0.05).There was no statistically significant difference in SD of coronary CTA,CT values and CNR between head and neck vessels (middle cerebral artery) in group A and group B (P>0.05).The effective dose of coronary CTA in group A (1.16±0.20) mSy was reduced by 51.1% than that in group B (2.37±0.77) mSv.The effective dose of head and neck CTA in group A (0.37±0.03) mSv was reduced by 47.9% than that in group B (0.71 ± 0.17) mSv.Conclusions The image quality with subjective evaluation met the diagnostic requirements when using a low-tube voltage for "one-stop"scanning of coronary and head and neck CTA.The CNR values were basically consistent with the conventional scanning method,and the patient effective dose was reduced by about 50%.
6.Research progress of neuroregeneration and multimodal neuromodulation in the treatment of spinal cord injury
Haoming FENG ; Shanzi YU ; Xiaobo ZHANG ; Wanjiang FENG ; Jianlong WANG
Clinical Medicine of China 2021;37(5):474-479
Spinal cord injury has a high rate of disability in clinical practice, which can be divided into complete SCI and incomplete SCI according to different injury segments and severity.The main purpose of treatment is to protect the nerves.At present, acute spinal cord injury is mainly treated with surgical decompression, neurotrophic treatment, hormone therapy, hypothermia therapy, rehabilitation intervention and other clinical comprehensive treatment.In recent years, breakthroughs have been made in the field of endogenous and exogenous neural stem cell research, and important progress has been made in the basic research of stem cell transplantation.In the long run, nerve regeneration and nerve modulation may be the most promising therapy for the repair of spinal cord injury.
7.Investigation on occupation-sex stereotype of male nursing students basing on IAT test
Qin MA ; Hua YU ; Qing WU ; Weilou SHAO ; Song QIU ; Wanjiang HE ; Meng LI ; Qiuyue WANG
Chinese Journal of Modern Nursing 2017;23(20):2679-2682
Objective To measure the occupation-sex stereotype, studying value and emotional stability of undergraduate nursing students (male), so as to provide further reference for exploring approaches of weakening or eliminating occupation-sex stereotype on male nursing students.Methods From November 2015 to November 2016, with method of convenience sampling, 54 undergraduate male nursing students from Grade I, II and III, from School of Nursing, of Kunming Medical University, were selected and were measured by Implicit association test (IAT), Studying value doubt scale and Eysenck emotional stability test.Results There were 34 male nursing students whose results of D-algorithm >0.5; 73.08% of the male nursing students had intensity of implicit sex stereotype>200 ms; 40.74% of the undergraduate male nursing students considered studying at the university valueless; more than 85% of the undergraduate male nursing students experienced inferiority complex or depression; over 65% were with obsession, hypochondriasis or low autonomy; a few were with anxiety or delusion of sin.Conclusions Occupation-sex stereotype is common among male nursing students. Several of the male nursing students considered studying at the university valueless. Emotional problems exist, like inferiority complex, depression, obsession and hypochondriasis.
8.Quantitative analysis of non-alcoholic fatty liver disease based on MRI proton density fat fraction in the coastal region of Qingdao
Yueli ZHU ; Zhipeng XU ; Wanjiang YU ; Yongning XIN ; Zhenzhen ZHAO ; Shousheng LIU ; Kuirong LYU
Chinese Journal of Hepatology 2021;29(11):1077-1082
Objective:To explore the clinical application value of MRI-PDFF on different liver segments for the evaluation of non-alcoholic fatty liver disease (NAFLD).Methods:178 volunteers from March 2019 to February 2020 were included. PDFF values ??of all nine segments of the liver were measured using CSE3.0T MRI scan. The obtained average value was used to represent the average liver fat content. PDFF values of each or combined liver segment were equally compared with the average value to observe the representativeness of fat content. Receiver operating characteristic curve was used to analyze the diagnostic performance of each liver segment, and the Youden index was used to calculate the cutoff value. Paired-sample t-test or non-parametric Kruskal-Wallis test were used to compare measurement data among groups.Results:178 volunteers average liver fat content ranged from 0.89% to 42.61% with MRI-PDFF, and 71.35% (127/178) of the volunteers had PDFF > 5%. There was no significant difference between SIII, SIVb, SV, and SVIII liver segments when compared with the average value ( P > 0.05). PDFF values ??of SI, SII, and SIV a liver segments were all lower than the average value, while the PDFF values ??of SVI and SVII liver segments were all higher than the average value ( P ??< 0.05). MRI-PDFF sensitivity value for diagnosing liver steatosis of nine liver segments was 85.8% ~ 94.5%, and the specificity was higher than 96.0%. Among them, the SV liver segment had the highest sensitivity (94.5%), and the corresponding optimal diagnostic threshold value was 5.13%. Compared with single and combined liver segment, the PDFF value of SII, SV, SVI combined liver segment had the highest diagnostic performance for fatty liver, with the sensitivity and specificity of 96.9%, and 100%, respectively, and the corresponding optimal diagnostic threshold value was 5.17%. Conclusion:Compared with single and other combined liver segments, MRI-PDFF values of SII, SV, and SVI combined liver segments have higher sensitivity and specificity for the diagnosis of NAFLD, and it can be used as the first choice for the determination of liver fat content with MRI.
9.Effect of Different Noise Index and Adaptive Statistical Interactive Reconstruction-Veo Selection on Double Energy CT
Han ZHANG ; Tiantian YIN ; Qiushi YANG ; Zeguo WANG ; Heli HAN ; Wanjiang YU
Chinese Journal of Medical Imaging 2024;32(10):1069-1074
Purpose Based on European lumbar spine phantom,to investigate the effect of different noise index(NI)combined with adaptive statistical interactive reconstruction-veo(ASiR-V)weights on the measurement of lumbar spine bone density,and to explore the optimal combination of the two parameters.Materials and Methods Using GE Revolution CT spectral imaging scanning,54 groups of scanning parameters with NI values of 4-20(interval 2)combined with ASiR-V weights of 0-100%(interval 20%)were selected for spectral scanning of European lumbar spine phantom.Regions of interest were placed in the middle of L1,L2 and L3,respectively.hydroxyapatite(HAP)-H2O based substances were selected to measure the HAP content of each vertebral body.The differences between the measured bone density value and the true value under different NI combined with different ASiR-V were compared to evaluate its accuracy.Results There were statistically significant differences in HAP measurements of L1,L2 and L3 vertebra in 54 groups of scanning conditions(all P<0.001).When NI=14,ASiR-V80%;NI=16,ASiR-V100%;NI=18,ASiR-V60%;NI=18,ASiR-V80%;NI=20,ASiR-V60%;NI=20,ASiR-V80%;NI=20,ASiR-V100%,there was no statistically significant difference between HAP measured value and true body model value(P>0.05).Conclusion With NI=18,ASiR-V60%,spectral CT can accurately measure lumbar spine bone density and significantly reduce the radiation dose.In clinical application,bone density can be measured by low dose scanning by increasing the weight of NI and ASiR-V.