1.Molecular mechanism underlining ethanol-induced chloride currents in nasopharyngeal carcinoma cells
Na LIN ; Wanhong ZUO ; Zhouyi LAI ; Jiabao WU ; Meiyuan CHEN ; Yuan WANG ; Lixin CHEN ; Liwei WANG
Chinese Journal of Pathophysiology 2014;(7):1179-1183
AIM:To study the effects and mechanisms of ethanol on chloride channels in poorly differentiated nasopharyngeal carcinoma CNE-2Z cells.METHODS:The effect of ethanol on the cell growth was analyzed by MTT as-say.The technique of whole-cell patch-clamp was used to detect the chloride current .The characteristics of the chloride current were analyzed by using the chloride channel blockers .The siRNA technique was used to analyze the molecular basis of the ethanol-sensitive chloride channels .RESULTS: Under isotonic conditions , the background current was weak and stable.Ethanol at concentrations of 0.17~170 mmol/L activated a chloride current in a concentration-dependent manner (an inverted U-shape), with a maximum effect at the concentration of 17 mmol/L.The currents showed obviously outward rectification and were susceptible to extracellular hypertonicity and the chloride channel blocker , 5-nitro-2-(3-phenylpropyl-amino) benzoic acid ( NPPB) .ClC-3 siRNA obviously decreased the currents activated by ethanol .CONCLUSION:Ex-tracellular ethanol induces chloride currents through activating the ClC-3 chloride channels .
2.Promoting blood circulation by removing blood stasis of Lubai Capsule
Wanhong ZHAO ; Yongxiao CAO ; Jing LIU ; Dejian WANG ; Qiaojuan SHI ; Changzheng LIN ; Jianp ZHENG
Chinese Traditional Patent Medicine 1992;0(06):-
Objective: To observe the promoting blood circulation by removing blood stasis of Lubai Capsule(LBC)(Rhizoma Phragmitis, Radix Paeoniae Alba, Radix Saposhnikoviae, Flos Schizonepetae, etc.). Methods: Acute blood stasis rat models were established with swimming in iced water and sc adrenalin in order to observe the effect of LBC on blood rheology. Mesenteric microcirculatory disturbance rat models were also established with adrenalin in order to observe the effect of LBC. Clotting time was measured in vitro with prothrombin time(PT) and kaolin partial thromboplastin time(KPTT) kit in order to observe its effects. Results: LBC could decrease the whole blood and plasma viscosity, fibrinogen, erythrocyte sedimentation and aggregation ratio of blood platelets of rats, ease the sticky condition of blood stasis rat models and prevent from forming thrombus. It could also inhibit the constraction and slowing of blood flow of thin artery, the reducing of open capillaries and change of fluid condition caused by adrenalin and improve these phenomena. PT and KPTT could be increased obviously. Conclusion: LBC can significantly promote blood circulation by removing blood stasis, because of improving blood rheology and mesenteric microcirculatory disturbance and inhibit endogenous and exogenous coagulation system.
3.Effectiveness of ADDIE instruction model in on-the-job training of neonatal transfer nurses
Wanhong WANG ; Yingying CAI ; Qiaohong WANG ; Binbin ZHUO ; Shaomei LIN
Modern Clinical Nursing 2024;23(4):85-90
Objective To explore the effectiveness of ADDIE instruction model(Analyse,Design,Develop,Implement,Evaluate)in the on-the-job training for neonatal transfer nurses to improve the comprehensive ability in life-saving as well as to ensure the safety of neonates during the transfer.Methods The pre-and post-control study in self-trained comparison was conducted with 35 neonatal nurses in our hospital.Thirty-five neonatal nurses in our hospital were included in a special training group for neonatal transport.According to the ADDIE instruction model,the training needs of nurses were analysed,special training protocols were designed and developed,training rules were implemented and the effects of training on the nurses were evaluated.Scores in professional theoretical knowledge,practical and various skills and teamwork and communication abilities in neonatal transfer were compared before and after the implementation of the ADDIE instruction model.Results All of the 35 nurses had completed the training and responded to the survey.The scores in professional theoretical knowledge,practical skills and teamwork and communication abilities in the neonatal transfer nurses were all significantly increased after the training with ADDIE instruction model(P<0.001).Conclusions On-the-job training of ADDIE instruction model among the neonatal transfer nurses can effectively enhance the professional knowledge and practice skills,enable the nurses to play a leading role in the process of treatment and improve abilities in teamwork and communication of the neonatal transfer nurses.The ADDIE instruction model provides valuable insights in the training of neonatal transfer nurses.
4.Study on the motion perception characteristics of lunar rover driving
Wei CHEN ; Shaoli XIE ; Ming AN ; Fang DU ; Fei GUO ; Wanhong LIN
Space Medicine & Medical Engineering 2024;35(2):116-120
The training of lunar rover driving skills for astronauts requires the simulation of realistic motion perception characteristics.The key lies in understanding the differences of driving motion perception between ground and moon.A high-fidelity simulation scene was created to compare the driving characteristics of a lunar rover on the moon and on Earth.Additionally,a software framework based on spatial orientation model was developed to simulate and compare the differences in forward motion perception between lunar and ground driving.The results indicate that under lunar conditions the lunar rover experiences reduced acceleration changes and slower acceleration and deceleration,which increases the displacement of sideslip.Additionally,limited visual information leads to a significantly larger dynamic pitch angle perception compared to ground conditions,while static pitch angle perception is greatly reduced.However,this difference could be greatly reduced when visual information is available.The differences in motion perception characteristics were revealed between lunar and ground driving rover,providing a basis for optimizing lunar rover driving motion simulation strategies.
5.Correlation between lung ultrasound score and postoperative pulmonary complications after cardiac surgery
KANG Hui ; ZHONG Xiaofei ; YANG Jian ; YIN Wanhong ; ZOU Tongjuan ; DENG Lijing ; YANG Jing ; LI Yi ; PU Huqiong ; JI Lin
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2019;26(7):688-692
Objective To investigate the correlation between lung ultrasonography and pulmonary complications after cardiac surgery. Methods Fifty-two patients after cardiac surgery in our hospital from January to May 2017 were recruited. There were 27 males and 25 females, aged 60.50±10.43 years. Lung ultrasonography was performed by specially trained observers, video data were saved, and lung ultrasound score (LUS) were recorded. The correlation between the LUS and the patients' pulmonary function was evaluated. Results LUS was 17.80±3.87, which was negatively correlated to the ratio of arterial PO2 to the inspired oxygen fraction (PaO2/FiO2) during examination, without significant difference (r=–0.363, P=0.095), but significantly negatively correlated to PaO2/FiO2 changes 24 hours postoperatively (r=–0.464, P=0.034). Conclusion The changes of lung ventilation area may occur earlier than the changes of lung function. Bedside LUS is an effective method for clinical monitoring of pulmonary complications.