1.Analgesic effect of cocktail therapy combined with femoral nerve block in unicompartmental knee arthroplasty
Guoliang WANG ; Fang PEI ; Dalin PENG ; Wangyi JIN ; Ziwen YAN ; Shen ZHOU ; Yuan WANG ; Kaijin GUO
Chinese Journal of Tissue Engineering Research 2024;28(30):4831-4836
BACKGROUND:With the further development of minimally invasive concepts,unicompartmental knee arthroplasty has become an important treatment for osteoarthritis of the knee;however,early postoperative pain adversely affects the recovery process,so effective analgesic measures are necessary.Femoral nerve block and cocktail therapy are common analgesic methods for unicompartmental knee arthroplasty,but there is a lack of studies confirming the analgesic effect and safety of their combined application. OBJECTIVE:To investigate the analgesic effect of cocktail therapy combined with femoral nerve block in unicompartmental knee arthroplasty. METHODS:One hundred patients who received unicompartmental knee arthroplasty from October 2021 to January 2023 were selected as the study subjects.They were divided into a control group(n=50)and a study group(n=50)using a random number table method.The femoral nerve block was used in the control group,while cocktail therapy combined with femoral nerve block was used in the study group during unicompartmental knee arthroplasty.Postoperative analgesia effect,analgesic frequency of dezocine injection within 2 days after surgery,motion range of affected knee joint,KSS function scores,and the occurrence of postoperative adverse reactions were compared between the two groups. RESULTS AND CONCLUSION:(1)Visual analog scale scores in the study group were lower than those in the control group at 12,24,and 48 hours after surgery(P<0.05).(2)The analgesic frequency of dezocine in the study group was less than that in the control group within 2 days after surgery(P<0.05).(3)The motion range in the study group was higher than that in the control group 1 and 3 days after surgery(P<0.05).On day 14 after surgery,there was no significant difference in motion range between the two groups(P>0.05).(4)The knee KSS score in the study group was higher than that in the control group at 2 weeks after surgery(P<0.05).There was no statistically significant difference in knee KSS scores between the two groups from 6 weeks to 6 months after surgery(P>0.05).(5)The difference in the occurrence of adverse reactions within 14 days after surgery was not significant between the two groups(P>0.05).(6)These results show that the use of cocktail therapy combined with femoral nerve block in unicompartmental knee arthroplasty can effectively reduce postoperative pain,improve the analgesic effect,reduce the frequency of analgesic drugs,and improve motion range of the early affected knee joint of patients.
2.Digital measurement of corneal curvature and eccentricity of guinea pigs using Python
Yue DI ; Xinyue LI ; Wangyi FANG ; Ying HUANG ; Wenting LUO ; Haiyun YE ; Zhongbao QIAO ; Tong QIAO
Chinese Journal of Experimental Ophthalmology 2023;41(8):724-729
Objective:To investigate an accurate and quantitative method to measure the eyeball morphological parameters of guinea pigs through a method that combines programmed digital techniques and mathematical geometric principles.Methods:Twenty-two three-week-old clean-grade male tricolor guinea pigs were selected and sacrificed by anesthesia overdose.Eyeballs were enucleated.The horizontal and sagittal images of the eyeball were taken with the high-speed photographic model of 13 million pixels macro meter, and the pictures were imported into pycharm programming software.Using the pre-written analysis program of Python 3.9, the conversion coefficient between the photo pixel and the actual length was obtained by a scale, and then the corneal surface was fitted by arc fitting and conic curve fitting.The results of arc fitting were converted to calculate the corneal radius of curvature.The corneal eccentricity was calculated according to the general conic equation (Ax 2+ Bxy+ Cy 2+ Dx+ Ey+ F=0). The corneal asphericity was evaluated by curve fitting between the central 3-mm and the whole cornea.The use and care of the animals complied with Regulations for the Administration of Affairs Concerning Experimental Animals by State Science and Technology Commission.The study protocol was approved by the Ethics Committee of Shanghai Public Health Clinical Center (No.2022-A009-01). Results:The digital method of Python programming can show the corneal contour of guinea pigs completely and clearly.In the transverse plane, there was no significant difference in the corneal curvature measurements among the digital fitting in central 3-mm cornea, digital fitting in whole cornea and curvature meter ( F=1.693, P=0.190). In the sagittal plane, there was a significant difference in the corneal curvature measurements among the three methods ( F=3.500, P=0.030), and the corneal curvature measurements of the whole cornea measured by the curvature meter were significantly greater than those measured by the digital fitting ( P<0.05). There was no statistical significance in the measurements of corneal curvature radius among the three methods in the transverse plane and the sagittal plane ( F=1.817, P=0.170; F=2.050, P=0.133). The horizontal and sagittal corneal eccentricity measured by digital fitting in central 3-mm cornea were 0.55±0.15 and 0.53±0.17, which were lower than 0.66±0.10 and 0.64±0.14 measured by digital fitting in whole cornea, and the differences were statistically significant ( t=-4.860, -5.210; both at P<0.01). Conclusions:It is feasible to use Python programming digital method to measure the corneal curvature and eccentricity of guinea pigs.