1.Structure-activity relationship optimization for lassa virus fusion inhibitors targeting the transmembrane domain of GP2.
Guangshun ZHANG ; Junyuan CAO ; Yan CAI ; Yang LIU ; Yanli LI ; Peilin WANG ; Jiao GUO ; Xiaoying JIA ; Mengmeng ZHANG ; Gengfu XIAO ; Yu GUO ; Wei WANG
Protein & Cell 2019;10(2):137-142
2.A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry.
Bo ZHENG ; Yi LIU ; Ruining ZHANG ; Wangwei YANG ; Fangju SU ; Rutao WANG ; Dapeng CHEN ; Guidong SHEN ; Yumin QIU ; Lianmin WANG ; Chang CHEN ; Zhongwei WU ; Fei LI ; Jiayi LI ; Chengxiang LI ; Chao GAO ; Ling TAO
Chinese Medical Journal 2023;136(15):1848-1854
BACKGROUND:
The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting.
METHODS:
The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan-Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves.
RESULTS:
A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54-3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year.
CONCLUSION:
The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent.
CLINICAL TRIAL REGISTRATION
ClinicalTrials.gov, NCT03916432.
Humans
;
Middle Aged
;
Sirolimus/therapeutic use*
;
Drug-Eluting Stents/adverse effects*
;
Prospective Studies
;
Cohort Studies
;
Treatment Outcome
;
Risk Factors
;
Time Factors
;
Percutaneous Coronary Intervention/adverse effects*
;
Cardiovascular Agents/therapeutic use*
;
Coronary Artery Disease/therapy*
;
Myocardial Infarction/etiology*
;
Thrombosis/complications*
;
Polymers
;
Registries