1.A highly sensitive bio-barcode immunoassay for multi-residue detection of organophosphate pesticides based on fluorescence anti-quenching
Xu LINGYUAN ; Zhang XIUYUAN ; El-Aty A.M.ABD ; Wang YUANSHANG ; Cao ZHEN ; Jia HUIYAN ; Salvador J.-PABLO ; Hacimuftuoglu AHMET ; Cui XUEYAN ; Zhang YUDAN ; Wang KUN ; She YONGXIN ; Jin FEN ; Zheng LUFEI ; Pujia BAIMA ; Wang JING ; Jin MAOJUN ; D.Hammock BRUCE
Journal of Pharmaceutical Analysis 2022;12(4):637-644
Balancing the risks and benefits of organophosphate pesticides(OPs)on human and environmental health relies partly on their accurate measurement.A highly sensitive fluorescence anti-quenching multi-residue bio-barcode immunoassay was developed to detect OPs(triazophos,parathion,and chlorpyrifos)in apples,turnips,cabbages,and rice.Gold nanoparticles were functionalized with monoclonal antibodies against the tested OPs.DNA oligonucleotides were complementarily hybridized with an RNA fluorescent label for signal amplification.The detection signals were generated by DNA-RNA hybridization and ribonuclease H dissociation of the fluorophore.The resulting fluorescence signal en-ables multiplexed quantification of triazophos,parathion,and chlorpyrifos residues over the concen-tration range of 0.01-25,0.01-50,and 0.1-50 ng/mL with limits of detection of 0.014,0.011,and 0.126 ng/mL,respectively.The mean recovery ranged between 80.3%and 110.8%with relative standard deviations of 7.3%-17.6%,which correlate well with results obtained by liquid chromatography-tandem mass spectrometry(LC-MS/MS).The proposed bio-barcode immunoassay is stable,reproducible and reliable,and is able to detect low residual levels of multi-residue OPs in agricultural products.
2.Personal glucose meters coupled with signal amplification technologies for quantitative detection of non-glucose targets:Recent progress and challenges in food safety hazards analysis
Feng HE ; Haijie WANG ; Pengfei DU ; Tengfei LI ; Weiting WANG ; Tianyu TAN ; Yaobo LIU ; Yanli MA ; Yuanshang WANG ; A.m.abd EL-ATY
Journal of Pharmaceutical Analysis 2023;13(3):223-238
Ensuring food safety is paramount worldwide.Developing effective detection methods to ensure food safety can be challenging owing to trace hazards,long detection time,and resource-poor sites,in addition to the matrix effects of food.Personal glucose meter(PGM),a classic point-of-care testing device,possesses unique application advantages,demonstrating promise in food safety.Currently,many studies have used PGM-based biosensors and signal amplification technologies to achieve sensitive and specific detection of food hazards.Signal amplification technologies have the potential to greatly improve the analytical performance and integration of PGMs with biosensors,which is crucial for solving the challenges associated with the use of PGMs for food safety analysis.This review introduces the basic detection principle of a PGM-based sensing strategy,which consists of three key factors:target recog-nition,signal transduction,and signal output.Representative studies of existing PGM-based sensing strategies combined with various signal amplification technologies(nanomaterial-loaded multienzyme labeling,nucleic acid reaction,DNAzyme catalysis,responsive nanomaterial encapsulation,and others)in the field of food safety detection are reviewed.Future perspectives and potential opportunities and challenges associated with PGMs in the field of food safety are discussed.Despite the need for complex sample preparation and the lack of standardization in the field,using PGMs in combination with signal amplification technology shows promise as a rapid and cost-effective method for food safety hazard analysis.