1.Risk Factors of Primary Nocturnal Enuresis.
Soo Jin LEE ; Jin Won YOOK ; Yoo Eun SUN ; Jung Wan SEO ; Sung Joo LEE
Journal of the Korean Society of Pediatric Nephrology 2000;4(1):69-76
Urinary cytology has become an essential element in the diagnosis and management of transitional cell carcinoma(TCC) of the urinary tract. It has the advantage of being noninvasive, inexpensive, and easily accessible. Besides that it can even detect malignancy when unsuspected at cystoscopy. We report a retrospective review of urine cytology in the diagnosis of 83 TCC cases that underwent 295 cytologic evaluation. All patients had biopsy-proven TCC of the bladder, ureter and renal pelvis. The overall inci- dence of the positive cytology cases was 66.2%. To define the cytologic features of tumor cells, we tried to use three cytologic gradings such as "grade 1", "grade 2", and "grade 3" according to the cytologic degree of anaplastic neoplastic cells. These cytologic gades of TCC were relatively well correlated with the histologic grade and tumor invasiveness. This result suggests that the recognition of characteristic cellular features of TCC can suspect the histologic grade and tumor stage. The false negative TCC cases were 78.9%. They showed severe inflammatory or bloody background and a few neoplastic cells. Therefore, a cautious approach for accurate interpretation, personal experience, and proper fixation and processing could expand the role of urinary cytology.
Cystoscopy
;
Diagnosis
;
Humans
;
Kidney Pelvis
;
Nocturnal Enuresis*
;
Retrospective Studies
;
Risk Factors*
;
Thyroid Gland
;
Ureter
;
Urinary Bladder
;
Urinary Tract
2.Factors Associated with Pneumothorax in Hyaline Membrane Disease In fants Receiving Mechanical Ventilation.
Oh Kyung LEE ; Kyung Hee KIM ; Kyu Sun CHOI ; Wan Seoub KIM
Journal of the Korean Pediatric Society 1989;32(12):1642-1649
No abstract available.
Humans
;
Hyalin*
;
Hyaline Membrane Disease*
;
Infant, Newborn
;
Pneumothorax*
;
Respiration, Artificial*
3.A case of serous surface papillary carcinoma.
In Gu WHANG ; Hak Bum SEO ; Young Tae KIM ; Kyu Wan LEE ; In Sun KIM
Korean Journal of Obstetrics and Gynecology 1992;35(4):613-617
No abstract available.
Carcinoma, Papillary*
4.Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system
Journal of Dental Rehabilitation and Applied Science 2024;40(2):72-81
Purpose:
This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removabledie system.
Materials and Methods:
The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RDgroup) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scannerto establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAMmilling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05).
Results:
The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions.
Conclusion
The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.
5.Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system
Journal of Dental Rehabilitation and Applied Science 2024;40(2):72-81
Purpose:
This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removabledie system.
Materials and Methods:
The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RDgroup) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scannerto establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAMmilling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05).
Results:
The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions.
Conclusion
The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.
6.Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system
Journal of Dental Rehabilitation and Applied Science 2024;40(2):72-81
Purpose:
This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removabledie system.
Materials and Methods:
The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RDgroup) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scannerto establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAMmilling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05).
Results:
The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions.
Conclusion
The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.
7.A standardization model based on image recognition for performance evaluation of an oral scanner.
Sang Wan SEO ; Wan Sun LEE ; Jae Young BYUN ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2017;9(6):409-415
PURPOSE: Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS: The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS: In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION: Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.
Dentistry
;
Tooth
8.Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method
Yoo Geum JEONG ; Wan Sun LEE ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2018;10(3):245-251
PURPOSE: To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS: First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS: The RMS value (152±52 µm) of the model manufactured by the milling method was significantly higher than the RMS value (52±9 µm) of the model produced by the 3D printing method. CONCLUSION: The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.
Dental Models
;
Dental Prosthesis
;
Methods
;
Printing, Three-Dimensional
;
Prostheses and Implants
;
Tooth
9.Antibacterial Activity of Water Soluble Components of Elfvingia applanata Alone and in Combinations with Quinolones.
Young So KIM ; Seong Kug EO ; Ki Wan OH ; Chong Kil LEE ; Young Nam LEE ; Seong Sun HAN
Mycobiology 2001;29(1):11-14
A preparation of water soluble components(EA) was made from carpophores of Elfvingia applanata(Pers.) Karst and its in vitro antibacterial activity on a number of bacterial species was examined by macrobroth dilution assay. Among 16 species of bacteria tested, the most potent antibacterial activity was observed against Staphylococcus epiderrnidis and Proteus vulgaris, of which MICs were 1.25 mg/ml. To investigate the antibacterial effects in combinations of EA with quinolone antibiotics, such as ciprofloxacin, enoxacin, lomefloxacin, norfloxacin, and ofloxacin, the fractional inhibitory concentrations(FICs) and the fractional inhibitory concentration indices(FICIs) for four bacterial strains were determined by macrobroth dilution checkerboard assay. Combinations of EA and quinolones exhibited either additive or indifferent effects of antibacterial activity in most instances. However, both synergistic and antagonistic effects were not observed in any cases.
Anti-Bacterial Agents
;
Bacteria
;
Ciprofloxacin
;
Enoxacin
;
Norfloxacin
;
Ofloxacin
;
Proteus vulgaris
;
Quinolones*
;
Staphylococcus
10.Predictive Factors of Saline Reduction under Ultrasound-guidance in Patients with Intussusception.
Jung Hye MIN ; Hye Young LEE ; Eun Sun YOO ; Jeong Wan SEO ; Seung Joo LEE ; Sun Hwa LEE
Journal of the Korean Pediatric Society 1999;42(2):221-226
PURPOSE: The purpose of this study was to investigate the predictive factors of saline reduction under ultrasound-guidance in patients with intussusception. METHODS: Ultrasound-guided saline enema reductions were performed in 105 patients with intussusception from September 1993 to April 1996 at Ewha Womans University Mok-dong Hospital. Clinical characteristics and ultrasonographic findings were analyzed as the predictive factors of ultrasound-guided saline enema reduction in 15 patients(14.3%) who were not reduced by saline enema reduction compared to 90 patients(85.7%) who were reduced. RESULTS: The mean age of the not-reduced group was 8.9+/-5.8 months old which was significantly younger than 14.5+/-15.4 months old of the reduced group(P<0.05) There were no significant differences in sex and clinical symptoms between the two groups(P>0.05). Among the ultrasonographic findings, the thickness of the hypoechoic outer rim in the not-reduced group was 10.5+/-3.3mm which was significantly thicker than 7.4+/-1.8mm of the reduced group(P<0.05). In stepwise logistic regression analysis, hypoechoic outer rim thickness over 8mm contributed significantly as the predictive factor for the failure of ultrasound-guided saline enema reduction(P<0.05). CONCLUSION: The thickness of the hypoechoic outer rim over 8mm on ultrasonogram was the predictive factor for the failure of saline reduction.
Enema
;
Female
;
Humans
;
Intussusception*
;
Logistic Models
;
Ultrasonography