1.Mechanisms of Homocysteine Neurotoxicity
Li-Shu WAN ; Yan REN ;
International Journal of Cerebrovascular Diseases 2006;0(12):-
Growing evidence indicates that hyperhomocysteinemia is not only a high risk factor for cerebrovascular diseases,but also closely correlated with neurodegenerative diseases and mental diseases,such as Alzheimer's disease,Parkinson's disease,dementia,cognitive impair- ment,depression and schizophrenia,The mechanisms of homocysteine neurotoxicity remains unclear,and it may include activating extracellular signal-regulated kinases,excessively activating glutamate receptors,participating in oxidative stress response,affecting methylation process and damaging DNA.
2.Acute toluene or xylene poisoning case analysis of domestic journals.
Jian-shu HUANG ; Yuan-ling ZHOU ; Wei-guo WAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2013;31(5):369-371
Acute Disease
;
Adolescent
;
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Toluene
;
poisoning
;
Xylenes
;
poisoning
;
Young Adult
4.Biomechanical study of neotype shape memory alloy cervical hook for atlantoaxial instability
Xiaoqiu SHU ; Lei WAN ; Dong YIN ; Chenglong LIU ; Anmin JIN
Chinese Journal of Tissue Engineering Research 2008;12(39):7764-7767
BAcKGROUND:In recent years,the pedicle screws fixation technique,which is used in fixation for atlantoaxial instability associated with trauma,severe degeneration and tumorectomy,has been developed.However,this kind of technique easily causes several complications,including malpositional screws,vascular injuries,and even vertebral artery injury.Based on the biomechanical characteristics of memory alloy and determination of atlantoaxial data,a neotype shape memory alloy cervical hook was designed to treat atlantoaxial instability.OBJECTIVE:To investigate the biomechanieal characteristics of the neotype shape memory alloy cervical hook for atlantoaxial instability.DESIGN,TIME AND SETTING:Repeated measurement analysis of variance test was performed in the Laboratory of Clinical Anatomy and Medical Biomechanics,Southern Medical University between March and April 2008.MATERIALS:Eight fresh adult craniocervical specimens(C0-C4)were provided by Department of Clinical Anatomy,Southern Medical University.Atlantoaxial neotype shape memory alloy cervical hook(50.8%-51.8%nickel and the remaining part was titanium)was fabricated by Shanghai Xinchang Memory Alloy Co.,Ltd.METHODS:The included eight C0-C4 specimens were used to test three-dimension ranges of motion(ROM)by fixation and neotype shape memory alloy cervical hook fixation.Then,the positions of spine varying from no loading to the maximum loading status were scanned and analyzed using image processing software to determine the three-dimensional ROM under different statuses.MAIN OUTCOME MEASURES:Three-dimensional ROM of tested specimens.RESULTS:Neotype shape memory alloy cervical hook fixation and Germany AESCULAP SSE hanger fixation had similar flexion-extension range of motion(P=0.595).Lateral bending three-dimensional ROM was greater in the neotype shape memory alloy cervical hook fixation group than in the Germany AESCULAP AAE hanger fixation(P< 0.05).The rotatory three-dimensional ROM was smaller in the neotype shape memory alloy cervical hook fixation group than in the Germany AESCULAP AAE hanger fixation(P<0.05).CONCLUSION:Neotype shape memory alloy cervical hook fixation had comparative post-surgery immediate stability with the Germany AESCULAP AAE hanger fixation.Neotype shape memory alloy cervical hook fixation produced a little worse biomechanical lateral bending stability and a little better biomechanical rotatory stability than Germany AESCULAP AAE hanger fixation.
7.Determination of methoxychlor in rabbit serum and its metabolic products with high performance liquid chromatography.
Xiao-yun ZHANG ; Wan-shu LI ; Li-kang ZHANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2010;28(8):622-624
Animals
;
Chromatography, High Pressure Liquid
;
methods
;
Methoxychlor
;
blood
;
metabolism
;
Phenols
;
blood
;
Rabbits
8.A study of a K~+ channel in the basolateral membrane of renal proximal tubule recorded from single rat nephron in vitro
Benlan YE ; Chongxiang SHU ; Jinglan DAI ; Weiping HOU ; Zibing WAN ;
Journal of Third Military Medical University 1988;0(05):-
Objective To study the physiological properties of a potassium channel in the basolateral membrane (BLM) of proximal tubule. Methods Nephrons were dissected from rat kidney under a stereoscopic microscope. The standard configuration for single channel tight seal patch clamp technique was used to record channel currents from the BLM. Results A kind of potassium channel with low conductance and inward rectification was easily recorded in the BLM of the proximal tubule. The channel current occurred spontaneously in 81% seals made on the BLM. In the patches, with no spontaneous channel activity, the channel current occurred when the pressure increased. In the inside out configuration, run down was present in channel activity. The open dwelling time constants of the potassium channel were 0.524 ms and 5.087 ms, while the closed dwelling time constants were 1.029 ms and 16.500 ms. Conclusion A type of potassium channels with low conductance, stretch sensibility and chemistry sensibility, presenting kinetic properties as two opening and two closing states, are widely distributed in the basolateral membrane of proximal tubule.
9.Preventive application of antibiotic in plastic surgery
Rui WAN ; Ying SHU ; Xingyuan PANG ; Jun REN
Chinese Journal of Medical Aesthetics and Cosmetology 2014;20(2):120-122
Objective To investigate the reasonable proposal of prophylactic antibiotics use in plastic surgery with type Ⅰ incision.Methods The data of 748 patients with plastic surgery in our hospital were collected and the operation number was 770.Using a retrospective case-control study,we analysed the clinical effect of different administration methods.Results Clinical effects were compared among the multiple days medication group,normative administration group and no medication groups,and there was no significant difference in the prevention of postoperative infection results.Conclusions Plastic surgery with type Ⅰ incision does not need the prophylactic application of antibiotics.In special circumstances we should take medicine in strict accordance with the Guiding Principles for Clinical Application of Antibiotics.
10.Effect of radiotherapy on neointima of prosthetic vascular graft after prosthetic vessel replacement of abdominal aorta
Jingqiang YAN ; Chang SHU ; Xiao ZHOU ; Heng WAN
Chinese Journal of General Surgery 1997;0(06):-
0.05) between the radiotherapy and control groups,and the coverage of vascular endothelial cell was incomplete in each group;8 weeks after surgery,the intimal thickness of radiotherapy group was statistically thinner than that of control group(P