1.A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae.
Danilo Alessio DI STEFANO ; Paolo AROSIO ; Adriano PIATTELLI ; Vittoria PERROTTI ; Giovanna IEZZI
The Journal of Advanced Prosthodontics 2015;7(1):51-55
PURPOSE: Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS: A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS: The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION: The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.
Bicuspid
;
Bone Density
;
Immediate Dental Implant Loading
;
Jaw
;
Maxilla*
;
Osseointegration
;
Rehabilitation
;
Tooth
2.The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
Danilo Alessio DI STEFANO ; Vittoria PERROTTI ; Gian Battista GRECO ; Claudia CAPPUCCI ; Paolo AROSIO ; Adriano PIATTELLI ; Giovanna IEZZI
The Journal of Advanced Prosthodontics 2018;10(3):227-235
PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS: Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS: Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION: The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.
Bone Density
;
Ribs