1.Field evaluation of repellency of a polyherbal essential oil against blackflies and its dermal toxicity using rat model
Sunil Dhiman ; Bipul Rabha ; Pronobesh Chattopadhyay ; Das, N.G. ; Hazarika, S. ; Bhola, R.K. ; Vijay Veer and Lokendra Singh
Tropical Biomedicine 2012;29(3):391-397
In the present study we have evaluated the repellent activity of mixture of Curcuma longa, Zanthoxylum limonella and Pogostemon heyneanus essential oils in 1:1:2 ratio at 5%, 10% and 20% concentration against blackflies in northeastern India. Initially the essential oil
mixture tested here has been found effective against Aedes albopictus mosquitoes. The average protection recorded in 20% concentration (170.56±4.0; 95% CI = 162.09-179.02) was
higher as compared to other two concentrations (F = 90.2; p<0.0001; df = 53). Percentage repellency and repellency index was found to be higher in 20% concentration (p<0.017). No appreciable clinical and behavioral signs were observed in the acute dermal toxicity using rat
model. No changes were observed in biochemical profiles of treatment group animals. Similarly, no prominent lesions were observed in vital organs of treatment in both the sexes. The study concludes that tested repellent is safe for use and has multi-insects repellent property.
2.Reproductive performance of genetically engineered mice housed in different housing systems.
Shikha YADAV ; Inderjeet YADAV ; Kunal PRATAP ; Pradeep Kumar TIWARI ; Vijay Pal SINGH
Laboratory Animal Research 2017;33(2):68-75
The genetically engineered mice require special husbandry care and are mainly housed in Individually Ventilated Cage (IVC) systems and Static Micro Isolator Cages (SMIC) to minimize the risk for spreading undesirable microorganisms. However, the static micro isolation cage housing like SMIC are being replaced with IVC systems in many facilities due to a number of benefits like a higher density housing in limited space, better protection from biohazards and allergens and decreased work load due to decreased frequency of cage changing required in this system. The purpose of this study was to examine the reproductive performance of genetically engineered mice housed in individually ventilated cages (IVC) and Static Micro Isolator Cages (SMIC). When the B6C3-Tg (APPswe, PSEN1dE9) 85Dbo/Mmjax transgenic mice were housed in these two housing systems, the number of litters per dam, number of pups born per dam and number of pups weaned per dam were found to be slightly higher in the IVC as compared to the SMIC but the difference was not significant (P<0.05). In case of Growth Associated Protein 43 (GAP-43) knockout mice, the number of litters born per dam and the number of pups born per dam were marginally higher in the IVC as compared to those housed in SMIC but the difference was not significant (P<0.05). Only the number of pups weaned per dam were found to be significantly higher as compared to those housed in the SMIC system at P<0.05.
Allergens
;
Animals
;
GAP-43 Protein
;
Hazardous Substances
;
Housing*
;
Mice*
;
Mice, Knockout
;
Mice, Transgenic
3.Comparison of the Efficacy of Caudal, Interlaminar, and Transforaminal Epidural Injections in Managing Lumbar Disc Herniation: Is One Method Superior to the Other?.
Laxmaiah MANCHIKANTI ; Vijay SINGH ; Vidyasagar PAMPATI ; Frank J E FALCO ; Joshua A HIRSCH
The Korean Journal of Pain 2015;28(1):11-21
BACKGROUND: Epidural injections are performed utilizing 3 approaches in the lumbar spine: caudal, interlaminar, and transforaminal. The literature on the efficacy of epidural injections has been sporadic. There are few high-quality randomized trials performed under fluoroscopy in managing disc herniation that have a long-term follow-up and appropriate outcome parameters. There is also a lack of literature comparing the efficacy of these 3 approaches. METHODS: This manuscript analyzes data from 3 randomized controlled trials that assessed a total of 360 patients with lumbar disc herniation. There were 120 patients per trial either receiving local anesthetic alone (60 patients) or local anesthetic with steroids (60 patients). RESULTS: Analysis showed similar efficacy for caudal, interlaminar, and transforaminal approaches in managing chronic pain and disability from disc herniation. The analysis of caudal epidural injections showed the potential superiority of steroids compared with local anesthetic alone a 2-year follow-up, based on the average relief per procedure. In the interlaminar group, results were somewhat superior for pain relief in the steroid group at 6 months and functional status at 12 months. Interlaminar epidurals provided improvement in a significantly higher proportion of patients. The proportion of patients nonresponsive to initial injections was also lower in the group for local anesthetic with steroid in the interlaminar trial. CONCLUSIONS: The results of this assessment show significant improvement in patients suffering from chronic lumbar disc herniation with 3 lumbar epidural approaches with local anesthetic alone, or using steroids with long-term follow-up of up to 2 years, in a contemporary interventional pain management setting.
Chronic Pain
;
Fluoroscopy
;
Follow-Up Studies
;
Humans
;
Injections, Epidural*
;
Pain Management
;
Radiculopathy
;
Spine
;
Steroids
6.Assessment of swallowing and masticatory performance in obturator wearers: a clinical study.
Nungotso VERO ; Niraj MISHRA ; Balendra Pratap SINGH ; Kamleshwar SINGH ; Sunit Kumar JUREL ; Vijay KUMAR
The Journal of Advanced Prosthodontics 2015;7(1):8-14
PURPOSE: To assess function by identifying changes in swallowing and masticatory performance in maxillary obturator prosthesis wearers. MATERIALS AND METHODS: Sixty subjects were recruited for the study, of which 20 were obturator wearers, 20 were completely dentulous and 20 had removable partial/complete dentures with similar Eichner's Index. Swallowing ability was evaluated with and without obturator using the "Water Drinking Test"; Masticatory performance was evaluated with the Sieve test; and maximum occlusal force was recorded with the help of a digital bite sensor. The data was analyzed using the Statistical Package for Social Science version 15.0 with a confidence level at 95%. RESULTS: Profile, behavior of drinking and time taken to drink were significantly improved (P<.001) in subjects after wearing obturator. Masticatory performance was not significantly different (P=.252) in obturator wearer when compared with dentulous or removable partial/complete denture wearer, but significantly (P<.001) high inter group difference in maximum occlusal force existed. Correlation between masticatory performance and maximum occlusal force was not significant (P=.124). CONCLUSION: Swallowing ability was significantly improved after wearing obturator but masticatory performance was not significantly different from those having similar occlusal support zone in their dentition.
Bite Force
;
Deglutition*
;
Dental Restoration Wear
;
Dentition
;
Dentures
;
Drinking
;
Mastication
;
Prostheses and Implants
;
Social Sciences
8.On-table reconstruction and fixation of Mason type III radial head fractures.
G N Kiran KUMAR ; Gaurav SHARMA ; Kamran FAROOQUE ; Vijay SHARMA ; Vaibhav JAIN ; Ravijot SINGH ; Vivek MOREY
Chinese Journal of Traumatology 2015;18(5):288-292
PURPOSETo evaluate the functional and radiological outcome of comminuted radial head fractures, which were not amenable for classical open reduction with internal fixation, treated by on-table reconstruction and fixation using low profile plates.
METHODSWe reviewed 6 patients of Mason type III radial head fractures treated by on-table reconstruction technique between 2011 and 2013. There were 5 men and 1 woman with a mean age of 35 years (range 25-46 years). All surgeries were carried out at our tertiary care level 1 trauma centre within a mean of 3 days (range 1-8 days) from date of injury using on-table reconstruction technique. The functional outcome was measured using elbow functional rating index described by Broberg and Morrey and the patient-based Disabilities of the Arm, Shoulder and Hand (DASH) outcome measure.
RESULTSThe mean follow-up period was 25 months. The average elbow flexion was 135°(range 125°-140°) and theaverage flexion contracture was 5°(range 0-10°). The average supination and pronation was 75°(range 70°-80°) and 70°(range 65°-82°) respectively. According to Broberg and Morrey scoring system, the average score was 90 points (range 75-100). The mean DASH score was 2.49 points.
CONCLUSIONOn-table reconstruction and fixation of comminuted radial head fractures using low profile plates is a reasonable option. The reconstructed radial head acts as spacer and provides reasonably good results and no surgical intervention is required for asymptomatic nonunion of these fractures regardless of the radiological findings.
Adult ; Bone Plates ; Female ; Fracture Fixation, Internal ; methods ; Fractures, Comminuted ; surgery ; Humans ; Male ; Middle Aged ; Radius Fractures ; surgery ; Reconstructive Surgical Procedures ; methods
9.Conjoint Nerve Root an Intraoperative Challenge in Minimally Invasive Tubular Discectomy
Ayush SHARMA ; Vijay SINGH ; Romit AGRAWAL ; Nilesh MANGALE ; Priyank DEEPAK ; Jeet SAVLA ; Ajay JAISWAL
Asian Spine Journal 2021;15(4):545-549
Conjoint nerve root (CNR) is an embryological nerve root anomaly that mainly involves the lumbosacral region. The presence of CNR during tubular discectomy raises the chances of failure in spinal surgery and the risk of neural injuries. Tubular discectomy can be challenging in the presence of CNR owing to limited visualization. Here, we present a technical note on two cases of L5–S1 disc prolapse in the presence of conjoint S1 nerve root that was operated via a minimally invasive tubular approach. Any intraoperative suspicion of CNR while using the tubular approach should prompt the surgeon to perform a thorough tubular decompression prior to nerve root retraction. In patients with a large disc, disc should be approached via the axilla because the axillary area between the dura and the medial boarder of the root is very easy to approach in the presence of CNR. Safe performance of tubular discectomy is possible even in the presence of CNR in the lumbar spine.
10.Conjoint Nerve Root an Intraoperative Challenge in Minimally Invasive Tubular Discectomy
Ayush SHARMA ; Vijay SINGH ; Romit AGRAWAL ; Nilesh MANGALE ; Priyank DEEPAK ; Jeet SAVLA ; Ajay JAISWAL
Asian Spine Journal 2021;15(4):545-549
Conjoint nerve root (CNR) is an embryological nerve root anomaly that mainly involves the lumbosacral region. The presence of CNR during tubular discectomy raises the chances of failure in spinal surgery and the risk of neural injuries. Tubular discectomy can be challenging in the presence of CNR owing to limited visualization. Here, we present a technical note on two cases of L5–S1 disc prolapse in the presence of conjoint S1 nerve root that was operated via a minimally invasive tubular approach. Any intraoperative suspicion of CNR while using the tubular approach should prompt the surgeon to perform a thorough tubular decompression prior to nerve root retraction. In patients with a large disc, disc should be approached via the axilla because the axillary area between the dura and the medial boarder of the root is very easy to approach in the presence of CNR. Safe performance of tubular discectomy is possible even in the presence of CNR in the lumbar spine.