3.Left ventricular systolic function between left bundle branch pacing and right ventricular septum pacing in patients with pacemaker dependence by three-dimensional speckle tracking imaging.
Heling WEN ; Yu CHEN ; Zhongshu LIANG
Journal of Central South University(Medical Sciences) 2021;46(4):379-384
OBJECTIVES:
To compare the left ventricular systolic function between the 1eft bundle branch pacing (LBBP) and right ventricular septum pacing (RVSP) in patients with pacemaker dependence by three-dimensional speckle tracking imaging (3D-STI).
METHODS:
A total of 65 patients with atrioventricular block (AVB) (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB), who underwent permanent cardiac pacing implantation including 32 patients receiving LBBP (LBBP group) and 33 patients receiving RVSP (RVSP group) from June 2018 to June 2019,were enrolled in this study. These patients met the following inclusion criterion: pre-operative left ventricular ejection fraction (LVEF)>50% and ventricular pacing rate>40% at 6-month programming follow-up; and the patients underwent echocardiography at pre-operation and 6 months after operation. The 3D-STI was used to obtain global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS).
RESULTS:
All the patients in the LBBP group and the RVSP group had normal LVEF, there was no significant difference between the 2 group (
CONCLUSIONS
For patients with pacemaker dependence and normal LVEF at pre-operation, the cardiac function in the LBBP group is not significantly better than that in the RVSP group in short term follow-up. But in terms of physiologic pacing and long-term cardiac function protection, the 1eft bundle branch pacing is an optimal pacing mode.
Bundle of His
;
Cardiac Pacing, Artificial
;
Humans
;
Pacemaker, Artificial
;
Stroke Volume
;
Ventricular Function, Left
;
Ventricular Septum/diagnostic imaging*
4.Interventricular septum motion abnormalities: unexpected echocardiographic changes of Brugada syndrome.
Zheng-rong HUANG ; Liang-long CHEN ; Wei-hua LI ; Qi-zhu TANG ; Cong-xin HUANG ; Qiang XIE ; Gang WU ; Lin FAN
Chinese Medical Journal 2007;120(21):1898-1901
BACKGROUNDThere remains controversy about whether Brugada syndrome (BS) has structural heart changes. We occasionally noted that a patient with BS had a quite unusual regional wall motion abnormality at the basal segment of the interventricular septum (IVS) during echocardiographic examination. The unexpected finding promoted us to reexamine our patients with BS by echocardiographic interrogation in the present study.
METHODSPatients with BS (n = 11), patients with complete right bundle branch block (RBBB) (n = 11), and control subjects (n = 11) were enrolled in this study. Two-dimensional echocardiography (2DE) was performed to obtain parasternal left ventricular long axis view on which M-mode scanning line was adjusted to be perpendicular to the basal segment of IVS for delineation of the segmental motion curve, with a simultaneously electrocardiographic tracing.
RESULTS2DE revealed a rapid swing motion shifting toward the right ventricle of the IVS basal segment at early systole in 73% (8/11) patients with BS, which was further confirmed on the M-mode curve evidenced by an early systolic notch toward the right ventricle. The position of the notch corresponded to C-point on the mitral motion curve, lasting for (53 +/- 5) ms. There were no similar changes both in patients with RBBB and in the control subjects.
CONCLUSIONIVS basal motion abnormalities at early-systolic phase may be the novel finding of BS.
Adult ; Aged ; Brugada Syndrome ; diagnostic imaging ; pathology ; physiopathology ; Echocardiography ; methods ; Female ; Humans ; Male ; Middle Aged ; Systole ; Ventricular Septum ; pathology ; physiopathology
5.Characteristics of Ventricular Function in Pulmonary Hypertension Patients with Different Shape of Interventricular Septum: Preliminary Study with Cardiac Magnetic Resonance Imaging.
Dan WANG ; Zhang ZHANG ; Fan YANG ; Le ZHANG ; Zhenwen YANG ; Wen REN ; Tielian YU ; Dong LI
Chinese Journal of Lung Cancer 2018;21(5):397-402
BACKGROUND:
To study the characteristics of ventricular function in Pulmonary Hypertension (PH) Patients with different shape of Interventricular Septum (IVS) by cardiac magnetic resonance (CMR).
METHODS:
36 PH patients diagnosed by right heart catheterization accepted CMR. According to the morphology of IVS, the patients were divided into two groups: the non-deformation group (10 patients) and the deformation group (26 patients). The ventricular function parameters were as follows: RV and LV end-diastolic volume index (EDVI), end-systolic volume index (ESVI), stroke volume index (SVI), cardiac index (CI), ejection fraction (EF), and myocardial mass index (MMI).
RESULTS:
ANOVA analysis showed that the differences of RVEDVI, RVESVI, RVSVI, RVCI, RVEF, RVMMI, LVEDVI, LVESVI, LVSVI and LVCI were significant among the three groups. Compared with control group, RVSVI (P=0.017), RVEF (P<0.001), LVEDVI (P=0.048) and LVSVI (P=0.015) decreased in IVS non-deformation group. Compared with IVS non-deformation group, RVEDVI (P<0.001), RVESVI (P<0.001), RVCI (P=0.002) and RVMMI (P=0.017) were increased in IVS deformation group; while RVEF (P=0.001), LVEDVI (P=0.003), LVSVI (P<0.001) and LVCI (P=0.029) were decreased. Compared with the control group, RVEDVI (P<0.001), RVESVI (P<0.001), RVCI (P=0.004) and RVMMI (P=0.003) were increased in the IVS deformation group, while RVEF (P<0.001), LVEDVI (P<0.001), LVESVI (P<0.001), LVSVI (P<0.001), LVCI (P<0.001) were decreased.
CONCLUSIONS
Ventricular function is different in PH Patients with different IVS shape. The IVS shape can represent the changes of ventricular function in PH patients.
Adult
;
Aged
;
Female
;
Heart
;
diagnostic imaging
;
physiopathology
;
Humans
;
Hypertension, Pulmonary
;
diagnosis
;
diagnostic imaging
;
physiopathology
;
Lung Neoplasms
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Stroke Volume
;
Ventricular Function
;
Ventricular Septum
;
diagnostic imaging
;
physiopathology
6.Right ventricular desynchronization in patients with pacemaker syndrome.
De-Zhen ZHOU ; Fan-Ping WEI ; Gao-Hui YUAN
Chinese Journal of Cardiology 2007;35(12):1108-1110
OBJECTIVETo observe the incidence of ventricular desynchronization in patients with or without pacemaker syndrome (PMS).
METHODSThe systolic peak velocity, the acceleration and the time to peak velocity of the interventricular septum (IVS), left ventricular (LV) and right ventricular (RV) lateral wall were detected by tissue Doppler imaging (TDI) in 14 atrial fibrillation patients without pacemaker implantation (control), 18 atrial fibrillation patients without PMS and 16 atrial fibrillation patients with PMS. All patients were free of valve disease, myocardial infarction, severe pulmonary hypertension, low left ventricular eject fraction (< or = 50%), significant segmental hypokinesis of ventricular wall or complete bundle branch block.
RESULTSCompared to the control patients, the systolic peak velocity and the accelerations on lateral walls of the LV and RV reduced significantly in patients with implanted pacemakers (P < 0.05). The intervals to peak velocity of the IVS and LV lateral walls were significantly prolonged [PMS group (80.13 +/- 26.92) ms vs. (25.60 +/- 4.30) ms, P < 0.01; without PMS group (76.22 +/- 23.32) ms vs. (25.60 +/- 4.30) ms, P < 0.01] and the intervals to peak velocity of the IVS and RV lateral walls significantly shortened [PMS group (16.33 +/- 6.85) ms vs. (40.70 +/- 7.60) ms, P < 0.01; without PMS group (21.20 +/- 7.34) ms vs. (40.70 +/- 7.60) ms, P < 0.01]. The systolic peak velocities, the accelerations of the IVS and bilateral walls and the intervals to peak velocity of the IVS and LV lateral wall were similar in patients with and without PMS (P > 0.05), however, the intervals to peak velocity of the IVS and RV lateral wall was significant shorter in patients with PMS compared to that of patients without PMS [(16.33 +/- 6.85) ms vs. (21.20 +/- 7.34) ms, P < 0.01].
CONCLUSIONRV desynchronization but not LV desynchronization might play an important role in patients with PMS.
Adult ; Aged ; Aged, 80 and over ; Atrial Fibrillation ; therapy ; Cardiac Pacing, Artificial ; adverse effects ; Echocardiography, Doppler, Pulsed ; Female ; Heart Ventricles ; diagnostic imaging ; physiopathology ; Humans ; Male ; Middle Aged ; Ventricular Septum
7.Abnormal Motion of the Interventricular Septum after Coronary Artery Bypass Graft Surgery: Comprehensive Evaluation with MR Imaging.
Seong Hoon CHOI ; Sang Il CHOI ; Eun Ju CHUN ; Huk Jae CHANG ; Kay Hyun PARK ; Cheong LIM ; Shin Jae KIM ; Joon Won KANG ; Tae Hwan LIM
Korean Journal of Radiology 2010;11(6):627-631
OBJECTIVE: To define the mechanism associated with abnormal septal motion (ASM) after coronary artery bypass graft surgery (CABG) using comprehensive MR imaging techniques. MATERIALS AND METHODS: Eighteen patients (mean age, 58 +/- 12 years; 15 males) were studied with comprehensive MR imaging using rest/stress perfusion, rest cine, and delayed enhancement (DE)-MR techniques before and after CABG. Myocardial tagging was also performed following CABG. Septal wall motion was compared in the ASM and non-ASM groups. Preoperative and postoperative results with regard to septal wall motion in the ASM group were also compared. We then analyzed circumferential strain after CABG in both the septal and lateral walls in the ASM group. RESULTS: All patients had normal septal wall motion and perfusion without evidence of non-viable myocardium prior to surgery. Postoperatively, ASM at rest and/or stress state was documented in 10 patients (56%). However, all of these had normal rest/stress perfusion and DE findings at the septum. Septal wall motion after CABG in the ASM group was significantly lower than that in the non-ASM group (2.1+/-5.3 mm vs. 14.9+/-4.7 mm in the non-ASM group; p < 0.001). In the ASM group, the degree of septal wall motion showed a significant decrease after CABG (preoperative vs. postoperative = 15.8+/-4.5 mm vs. 2.1+/-5.3 mm; p = 0.007). In the ASM group after CABG, circumferential shortening of the septum was even larger than that of the lateral wall (-20.89+/-5.41 vs. -15.41+/-3.7, p < 0.05) CONCLUSION: Abnormal septal motion might not be caused by ischemic insult. We suggest that ASM might occur due to an increase in anterior cardiac mobility after incision of the pericardium.
Contrast Media/diagnostic use
;
*Coronary Artery Bypass
;
Coronary Disease/*surgery
;
Female
;
Gadolinium DTPA/diagnostic use
;
Humans
;
Image Interpretation, Computer-Assisted
;
Magnetic Resonance Imaging/*methods
;
Male
;
Middle Aged
;
Pericardium/surgery
;
Retrospective Studies
;
Statistics, Nonparametric
;
Ventricular Septum/*physiopathology