1.Routine Urinalysis in Renal Diseases.
Journal of the Korean Academy of Family Medicine 2003;24(2):112-121
No abstract available.
Urinalysis*
2.Urinalysis.
Journal of the Korean Pediatric Society 1999;42(1):1-5
No abstract available.
Urinalysis*
3.Urinalysis.
Journal of the Korean Pediatric Society 1999;42(1):1-5
No abstract available.
Urinalysis*
4.More Than the Significance of Conventional Urinalysis.
International Neurourology Journal 2013;17(4):153-154
No abstract available.
Urinalysis*
5.Urinalysis finding in traumatized patients.
Heung Zu KIM ; Sung Chul YUN ; Moon Jib YOO ; Phil Hyun CHUNG
Korean Journal of Nephrology 1991;10(1):25-31
No abstract available.
Humans
;
Urinalysis*
6.Laboratory Evaluation of Automated Urine Analyzer ComboStick Reader 720(R) and Reagent Strip ComboStick 10.
Min Jung KWON ; Hyup Woo LEE ; Ga Yeong KIM ; Myeong Hyeon NAM ; Chang Kyu LEE ; Young Kee KIM
Journal of Laboratory Medicine and Quality Assurance 2009;31(1):215-223
BACKGROUND: The ComboStick Reader 720(R)(DFI Co., Ltd. Korda) is a newly developed automated urine analyzer. The objective of this analysis was to evaluate the analytical performance of the Combostick Reader 720 and ComboStick 10 reagent strips and to compare the results using the Uriscan Pro II and Uriscan Gen 10 SGL strips (YD Diagnostics, Korea). METHODS: The Dipstick urinalyses were performed on a ComboStick Reader 720(R) using ComboStick 10 strips and on a Uriscan Pro II(R) using Uriscan 10 SGL strips. Precision was evaluated with commercial control materials. The sets of results were analyzed for concordance with weighted kappa values or intraclass correlation coefficients (ICCs). The microscopic urine analysis was carried out to confirm the results from both automated urine analyzers. Agreement between the dipstick methods and the microscopic method was evaluated by kappa values and the McNemar test. RESULTS: Within and between-run precisions of the ComboStick Reader 720(R) were 90.0% to 100%. A comparison of results from 1,700 urine samples using the ComboStick Reader 720(R) and Uriscan Pro II(R) revealed a very high concordance rate of > or = 91.0% on consideration of neighboring blocks for all analytes of the dipstick urinalysis. There was a good association between the microscopic method and the dipstick methods of the two automated urine analyzers. The ComboStick Reader 720(R) revealed a statistically higher degree of agreement for leukocytes. CONCLUSIONS: The ComboStick Reader 720(R) and ComboStick 10 strips showed good precisions and revealed a statistically significant agreement with the Uriscan Pro II(R) and Uriscan 10 SGL strips. For leukocytes, the ComboStick Reader 720(R) was superior to the Uriscan Pro II(R) in comparing the agreement between the microscopic and dipstick methods. The overall performance of the ComboStick Reader 720(R) and ComboStick 10 strips were satisfactory.
Leukocytes
;
Reagent Strips
;
Urinalysis
7.The Clinical Use of Routine Urinalysis.
Journal of the Korean Society of Pediatric Nephrology 2013;17(2):35-41
Routine urinalysis is a simple, economical, and useful test that facilitates the detection of urinary system diseases and monitoring of renal disease progression. It consists of 4 parts of specimen evaluation, gross examination, a dipstick urinalysis, and a sediment microscopic urinalysis. Urine specimens should first be evaluated in terms of acceptability, and thereafter, the gross appearance is examined for color, turbidity, and odor. In particular, a dipstick urinalysis is an easy and rapid test that provides information on the multiple physicochemical properties of the urine sample. Moreover, although a sediment microscopic urinalysis is time-consuming, it provides information on the cells, microorganisms, casts, and crystals. In the present report, the clinical significance of the routine urinalysis and the problems concerning interpretation are summarized.
Disease Progression
;
Odors
;
Urinalysis*
8.Bullous Necrotizing Vasculitis of the Skin.
Pyung Won PARK ; Chang Woo LEE ; Jae Hong KIM
Annals of Dermatology 1993;5(2):113-116
Three cases of necrotizing vasculitis clinically showing bullous skin lesions and histopathologically confirmed as leukocytoclastic vasculitis are reported. Compared with those of skin -limited non-bullous forms of cutaneous vasculitis, these cases showed relatively frequent abnormalities in urinalysis and required more aggresive corticosteriod therapy. Clinicians should be aware of the possible systemic involvements when the skin lesions are bullous in cutaneous necrotizing vasculitis.
Skin*
;
Urinalysis
;
Vasculitis*
9.Investigation of renal function test and urinalysis findings onhepatitis B surface antigen positive patients.
Korean Journal of Clinical Pathology 1993;13(1):19-24
No abstract available.
Antigens, Surface*
;
Humans
;
Urinalysis*
10.Investigation of renal function test and urinalysis findings onhepatitis B surface antigen positive patients.
Korean Journal of Clinical Pathology 1993;13(1):19-24
No abstract available.
Antigens, Surface*
;
Humans
;
Urinalysis*