1.Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea.
Hyun Jung KIM ; Cho Ae LEE ; Eun Kyung HWANG ; Man Young HAN ; Uk Sung ANN ; Young Min CHO
Journal of the Korean Pediatric Society 2003;46(12):1235-1241
PURPOSE: We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. METHODS: The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/ Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/ Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. RESULTS: Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of 3.76 m. All combinations other than Pariboy Type N/Long life produced a MMAD of over 5 m. MMAD over a 5 min nebulization ranged 3.76 to 9.83 m. There were no significant effects of fill volume on mass output. CONCLUSIONS: We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.
Korea*
;
Nebulizers and Vaporizers
;
Particle Size
;
Respiratory Therapy
2.Microinvasive Carcinoma of the Uterine Cervix: Diagnosis and Management Pattern.
Sung Hoon ROH ; Ki Heon LEE ; Ha Kyun SONG ; Hyun Kyong ANN ; Kyung Ryul HAM ; Ok Rim KANG ; Tae Jin KIM ; Kyung Taek LIM ; Jae Uk SHIM ; Jong Soo CHUN ; In Sou PARK ; Chong Taek PARK
Korean Journal of Gynecologic Oncology and Colposcopy 1997;8(2):130-140
Microinvasive carcinoma of the uterine cervix(FIGO stage IA) has been reported as highly curable disease even with conservative surgery such as conization and simple hysterectomy. Nevertheless, the surgical management for microinvasive carcinomas has been proposed varying from conservative surgery to radical hysterectomy with pelvic nodes dissection according to different diagnostic criterias for microinvasive carcinoma. We reviewed 512 patients who had been diagnosed as microinvasive carcinoma of the uterine cervix at the Department of Obstetrics and Gynecology, Samsung Cheil Hospital and Women's Healthcare Center from Jan. 1988 to Dec. 1995. Among them, 376 patients were included in this study satisfying guided criterias such as proper management and follow up more than at least one year, and they were analyzed retrospectively based on the clinicopathologic characteristics, pattern of surgical management and postoperative status. (continue)
Cervix Uteri*
;
Conization
;
Delivery of Health Care
;
Diagnosis*
;
Female
;
Follow-Up Studies
;
Gynecology
;
Humans
;
Hysterectomy
;
Obstetrics
;
Retrospective Studies