1.Accuracy of virtual models in the assessment of maxillary defects.
Kivanc KAMBUROGLU ; Sebnem KURSUN ; Cenk KILIC ; Tuncer OZEN
Imaging Science in Dentistry 2015;45(1):23-29
PURPOSE: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. MATERIALS AND METHODS: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) 60x60 mm FOV, 0.125 mm3 (FOV60); 2) 80x80 mm FOV, 0.160 mm3 (FOV80); and 3) 100x100 mm FOV, 0.250 mm3 (FOV100). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. RESULTS: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. CONCLUSION: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.
Cadaver
;
Cone-Beam Computed Tomography
;
Dimensional Measurement Accuracy
;
Linear Models
;
Maxillofacial Prosthesis
;
Palate, Hard
;
Silicones
2.Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars.
Buket ACAR ; Kivanc KAMBUROGLU ; Ilkan TATAR ; Volkan ARIKAN ; Hakan Hamdi CELIK ; Selcen YUKSEL ; Tuncer OZEN
Imaging Science in Dentistry 2015;45(4):205-211
PURPOSE: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. MATERIALS AND METHODS: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. RESULTS: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. CONCLUSION: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.
Cone-Beam Computed Tomography*
;
Decalcification Technique
;
Dental Pulp Cavity
;
Humans
;
Molar*
;
Tooth, Deciduous
;
X-Ray Microtomography
3.Cytotoxic effects of different self-adhesive resin cements: Cell viability and induction of apoptosis
Soner ŞIŞMANOĞLU ; Mustafa DEMIRCI ; Helmut SCHWEIKL ; Gunes OZEN-EROGLU ; Esin CETIN-AKTAS ; Serap KURUCA ; Safa TUNCER ; Neslihan TEKCE
The Journal of Advanced Prosthodontics 2020;12(2):89-99
PURPOSE:
. The effects of four different self-adhesive resin cement materials on cell viability and apoptosis after direct and indirect exposure were evaluated using different cell culture techniques.
MATERIALS AND METHODS:
. Self-adhesive cements were applied to NIH/3T3 mouse fibroblasts by the extract test method, cell culture inserts, and dentin barrier test method. After exposure periods of 24 h and 72 h, the cytotoxicity of these self-adhesive materials was evaluated using the MTT assay (viability) and the Annexin-V-FITC/PI staining (apoptosis).
RESULTS:
.The lowest cell viability was found in cells exposed to BeautiCem SA for 24 h in the extract test method. Cell viability was reduced to 70.6% compared to negative controls. After the 72 h exposure period, viability rate of cell cultures exposed to BeautiCem SA decreased more than 2- fold (29.5%) while cells exposed to RelyX U200 showed the highest viability rate of 71.4%. In the dentin barrier test method, BeautiCem SA induced the highest number of cells in apoptosis after a 24 h exposure (4.1%). Panavia SA Cement Plus was the material that caused the lowest number of cells in apoptosis (1.5%).
CONCLUSION
. The used self-adhesive cements have showed different cytotoxic effects based on the evaluation method. As exposure time increased, the materials showed more cytotoxic and apoptotic effects. BeautiCem SA caused significantly more severe cytotoxic and apoptotic effects than other cements tested. Moreover, cements other than BeautiCem SA have caused necrotic cell death rather than apoptotic cell death.