1.IDENTIFICATION OF HUMAN MURR1, THE HOMOLOGUE OF MOUSE IMPRINTED Murr1 GENE
Zhongming ZHANG ; Youdong WANG ; Yatsuki HITOMI ; Joh KEIICHIRO ; Iwasaka TSUYOSHI ; Mukai TSUNEHIRO
Journal of Pharmaceutical Analysis 2006;18(2):161-166,170
Objective To identify the mRNA sequence, genetic construction, imprinting status, and expression profile of human MURR1 gene, the homologue of mouse imprinted Murr1 gene. Methods The MURR1 mRNA sequence was identified by colony hybridization screening of human cDNA library and the 5'-RACE analyses; Absence of U2AF1-RS1 gene within MURR1 was confirmed by Southern Blotting; Expression profile of MURR1 was examined by Northern Blotting; The imprinting status of MURR1 were revealed by SNP investigation and RT-PCR followed by sequencings and RFLP analyses. Results The full-length mRNA sequence of MURR1 spans 711 bp, transcribed from 3 exons, encodes predicted MURR1 protein of 190 amino acids. The gene was expressed in all the 12 kinds of human adult tissues and 6 kinds of fetal tissues. It showed biallelic expression in all 32 investigated samples including 6 kinds of human fetal tissues and 8 adult brains. Unlike mouse imprinted U2af1-rs1 gene existing in the intron of Murr1, the human U2AF1-RS1 gene was not located in the MURR1 locus. Conclusion Human MURR1 gene is not imprinted and the non-imprinting is possible due to the absence of human homologue of mouse U2af1-rs1 within MURR1 locus.
2.Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration
Mitsuru OKUNO ; Keisuke IWATA ; Tsuyoshi MUKAI ; Yusuke KITO ; Takuji TANAKA ; Naoki WATANABE ; Senji KASAHARA ; Yuhei IWASA ; Akihiko SUGIYAMA ; Youichi NISHIGAKI ; Yuhei SHIBATA ; Junichi KITAGAWA ; Takuji IWASHITA ; Eiichi TOMITA ; Masahito SHIMIZU
Clinical Endoscopy 2024;57(3):364-374
Background/Aims:
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML).
Methods:
Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles.
Results:
Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1–6] vs. 4 [1–6], p=0.023). There were no significant differences in cytological/histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group.
Conclusions
Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.