1.Using ImageJ to Evaluate Optic Disc Pallor in Traumatic Optic Neuropathy.
Sunah KANG ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2014;28(2):164-169
PURPOSE: To evaluate optic disc pallor using ImageJ in traumatic optic neuropathy (TON). METHODS: This study examined unilateral TON patients. The optic disc was divided into 4 quadrants (temporal, superior, nasal, and inferior), consistent with the quadrants on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness maps. Optic disc photography was performed and disc pallor was quantified using gray scale photographic images imported into ImageJ software. The correlation between optic disc pallor and RNFL thickness was examined in each quadrant. RESULTS: A total of 35 patients (31 male, 4 female) were enrolled in the study. The mean participant age was 34.8 +/- 15.0 years (range, 5 to 63 years). Overall RNFL thickness decreased in 6 patients, with thinning most often occurring in the inferior quadrant (28 of 35 eyes). There was a significant correlation between optic disc pallor and RNFL thickness (superior, rho = -0.358, p = 0.04; inferior, rho = -0.345, p = 0.04; nasal, rho = -0.417, p = 0.01; temporal, rho = -0.390, p = 0.02). The highest level of correspondence between disc pallor and RNFL thickness values outside of the normative 95th percentiles was 39.3% and occurred in the inferior quadrant. CONCLUSIONS: Optic disc pallor in TON was quantified with ImageJ and was significantly correlated with RNFL thickness abnormalities. Thus, ImageJ evaluations of disc pallor may be useful for evaluating RNFL thinning, as verified by OCT RNFL analyses.
Adolescent
;
Adult
;
Child
;
Child, Preschool
;
Colorimetry/methods/standards
;
Diagnosis, Computer-Assisted/*methods/standards
;
Female
;
Humans
;
Male
;
Middle Aged
;
Optic Atrophy/etiology/*pathology
;
Optic Nerve Diseases/etiology/*pathology
;
Optic Nerve Injuries/*pathology
;
Photography/*methods/standards
;
Reproducibility of Results
;
Software
;
Tomography, Optical Coherence/*methods/standards
;
Trauma Severity Indices
;
Young Adult
2.The Effect of Various Factors on Variability of Retinal Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography.
Dong Ju YOUM ; Hyunjoong KIM ; Seong Hee SHIM ; Hyo Ju JANG ; Joon Mo KIM ; Ki Ho PARK ; Chul Young CHOI ; Jung Gon CHO
Korean Journal of Ophthalmology 2012;26(2):104-110
PURPOSE: To evaluate the effects of various factors on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. METHODS: Four hundred seventy-four subjects (103 normal eyes and 371 glaucomatous eyes) were scanned to determine the RNFL thickness measurements using the Stratus OCT. Measurements were obtained twice during the same day. The standard deviation (SD) was used to compare the variability in RNFL thickness measurements of the normal subjects to that of the glaucomatous patients. Multivariate regression analysis was used to evaluate which covariates were independent predictors of SD in overall mean RNFL thickness. RESULTS: The mean SD of all RNFL thickness measurements was larger in the glaucoma group except in one sector. In the multivariate regression analysis, the average signal strength (SS) and the relative SS change (difference in SS between initial and repeat scans, divided by initial SS) were independent predictors of the SD in the RNFL thickness measurements (partial R2 = 0.018, 0.013; p = 0.016, 0.040, respectively). CONCLUSIONS: Glaucomatous eyes tend to be more variable than normal eyes in RNFL thickness measurement using the Straus OCT. The average SS and the relative SS changes appear to correlate with the variability in RNFL thickness measurement. Therefore, the results of the RNFL analysis should not be interpreted independently of these factors.
Aged
;
Female
;
Glaucoma/*pathology
;
Humans
;
Male
;
Middle Aged
;
Multivariate Analysis
;
Nerve Fibers/*pathology
;
Predictive Value of Tests
;
Reference Values
;
Regression Analysis
;
Reproducibility of Results
;
Retina/*cytology/*pathology
;
Tomography, Optical Coherence/*methods/*standards
3.Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography in Pseudophakic Eyes.
Gyu Ah KIM ; Ji Hyun KIM ; Jun Mo LEE ; Kyoung Soo PARK
Korean Journal of Ophthalmology 2014;28(2):138-149
PURPOSE: To assess the reproducibility of circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurement (measurement agreement) and its color-coded classification (classification agreement) by Cirrus spectral domain optical coherence tomography (OCT) in pseudophakic eyes. METHODS: Two-hundred five participants having glaucoma or glaucoma suspected eyes underwent two repeated Cirrus OCT scans to measure cpRNFL thickness (optic disc cube 200 x 200). After classifying participants into three different groups according to their lens status (clear media, cataract, and pseudophakic), values of intra-class coefficient (ICC), coefficient of variance, and test-retest variability were compared between groups for average retinal nerve fiber layer (RNFL) thicknesses and that corresponding to four quadrant maps. Linear weighted kappa coefficients were calculated as indicators of agreement of color code classification in each group. RESULTS: ICC values were all excellent (generally defined as 0.75 to 1.00) for the average and quadrant RNFL thicknesses in all three groups. ICC values of the clear media group tended to be higher than those in the cataract and pseudophakic groups for all quadrants and average thickness. Especially in the superior and nasal quadrants, the ICC value of the cataract group was significantly lower than that of the clear media and pseudophakic groups. For average RNFL thickness, classification agreement (kappa) in three groups did not show a statistically significant difference. For quadrant maps, classification agreement (kappa) in the clear media group was higher than those in the other two groups. CONCLUSIONS: Agreement of cpRNFL measurement and its color code classification between two repeated Cirrus OCT scans in pseudophakic eyes was as good as that in eyes with clear crystalline lens. More studies are required to ascertain the effect of lens status on the reproducibility of Cirrus OCT according to different stages of glaucoma patients.
Aged
;
Cataract/complications
;
Cataract Extraction
;
Female
;
Glaucoma/complications/*pathology
;
Humans
;
Lens, Crystalline/cytology/pathology
;
Male
;
Middle Aged
;
Nerve Fibers/pathology
;
Optic Disk/pathology
;
Pseudophakia/complications
;
Reproducibility of Results
;
Retinal Ganglion Cells/*pathology
;
Tomography, Optical Coherence/*methods/*standards