1.Quadricuspid Aortic Valve Associated with Mitral Regurgitation and Tricuspid Regurgitation
Masato Hayakawa ; Takeshi Kinoshita ; Shiho Naito ; Noriyuki Takashima ; Satoshi Kuroyanagi ; Hiromitsu Nota ; Tomoaki Suzuki ; Tohru Asai
Japanese Journal of Cardiovascular Surgery 2013;42(3):190-192
Congenital quadricuspid aortic valve is a very rare malformation. Most cases have been discovered as an incidental finding at aortic valve surgery or at autopsy. It frequently evolves to aortic regurgitation, which can manifest in adulthood and may require surgical treatment. A 66-year-old man was admitted because of dysprea. Echocardiogram revealed aortic regurgitation, mitral regurgitation, and tricuspid regurgitation. We performed aortic valve replacement, mitral annuloplasty, and tricuspid annuloplasty successfully. The aortic valve showed one large, two intermediate and one smaller cusp, which were classified as typed by Hurwitz's classification. An accessory cusp was situated between the right and left coronary cusps. No coronary abnormality was involved. The postoperative course was uneventful and he is doing well 6 months after operation.
2.In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium
Ginga SUZUKI ; Satoshi SHIMIZU ; Mana TORII ; Ai TOKUE ; Guo YING ; Masao YOSHINARI ; Noriyuki HOSHI ; Katsuhiko KIMOTO ; Hiromi MIURA ; Tohru HAYAKAWA ; Chikahiro OHKUBO
The Journal of Advanced Prosthodontics 2020;12(6):369-375
PURPOSE:
This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure.
MATERIALS AND METHODS:
The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test.
RESULTS:
Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/ rpm in machinability tests (P<.05).
CONCLUSION
Although the wear resistance and plaque adherence of MDFTi were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.
3.In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium
Ginga SUZUKI ; Satoshi SHIMIZU ; Mana TORII ; Ai TOKUE ; Guo YING ; Masao YOSHINARI ; Noriyuki HOSHI ; Katsuhiko KIMOTO ; Hiromi MIURA ; Tohru HAYAKAWA ; Chikahiro OHKUBO
The Journal of Advanced Prosthodontics 2020;12(6):369-375
PURPOSE:
This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure.
MATERIALS AND METHODS:
The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test.
RESULTS:
Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/ rpm in machinability tests (P<.05).
CONCLUSION
Although the wear resistance and plaque adherence of MDFTi were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.
4.Effect of Catechol-O-Methyltransferase Genotype on Self-Reported Efficacy and Activity Changes in the Brain Prefrontal Area in Response to a Caffeine Placebo
Minae ISAWA ; Yuka YOKOYAMA ; Mei HORIUCHI ; Miku KAJIYAMA ; Nanami ARAI ; Nao ISHIMOTO ; Hideo NAKADA ; Tomohisa HAYAKAWA ; Haruki ISHIKAWA ; Mayumi MOCHIZUKI ; Tohru AOMORI
Japanese Journal of Drug Informatics 2023;24(4):196-205
Objective: The placebo effect can enhance the response to treatment, even in the absence of pharmacological ingredients. One possible factor explaining the likelihood of the placebo effect in individuals is genetic polymorphisms in neurotransmitters. This study focused on gene polymorphisms in the catechol-O-methyltransferase (COMT) as an interindividual variable of the placebo effect.Design・Methods: All 120 participants were explained the effects of caffeine, including its ability to ameliorate drowsiness and increase concentration, and then given a placebo (lactose). The onset of the placebo effect was measured in terms of the degree of caffeine-reduced sleepiness using subjective indices of the Stanford Sleepiness Scale (SSS) and a feeling of drowsiness-Visual Analogue Scale (VAS). The mechanism of the placebo effect was objectively examined in terms of changes in cerebral blood flow in the prefrontal cortex of the brain. In addition, we investigated participants’ susceptibility to the placebo effect by examining genetic polymorphisms in COMT.Results: After taking the drug, sleepiness on the SSS and VAS was significantly improved (p<0.001), although there was no change in prefrontal cortex activity. Among the 120 participants, 63 had a Val/Val-type polymorphism in COMT (52.5%), 45 had a Val/Met-type (37.5%), and 12 had a Met/Met-type (10.0%). There were no significant differences among COMT gene polymorphisms in the subjective measures of SSS and VAS. However, there was a tendency for the cerebral blood flow changes to be larger in the left hemisphere of the brain in individuals with the Met/Met type.Conclusion: There seems to be a relationship between prefrontal cortex activity and genetic polymorphisms. In particular, there may be a correlation between the expression of a placebo effect and COMT gene polymorphisms.