1.Baicalin attenuates Aβ25-35 induced learning and memory disorders in mice and its possible mechanism
Wan XIAO ; Xiaolu CAO ; Rong ZHANG ; Chengzhi GAO ; Jing DU ; Tingzi YIN ; Ying ZHANG ; Xing HONG ; Xiamin HU ; Bo REN
Chinese Journal of Pharmacology and Toxicology 2017;31(1):59-64
OBJECTIVE To observe the effect of baicalin on Aβ25-35 induced learning and memory deficits and changes in autophagy-related genes in mice so as to explore the related mechanisms of Alzheimer disease (AD) treatment . METHODS C57 mice were administered with 3μL Aβ25-35 3 mmol·L-1 by intracerebroventricular injection to establish an AD model. Baicalin was given by intracerebroventricular injection at the dose of 25, 50 and 100 mg · kg-1 for 15 d, respectively. The total distance and the central grid residence time were measured in the open-field test. The escape latency and the time to reach the platform were monitored in the Morris water maze trial. The autophagic vacuoles in the hippocampus of the mice were observed by transmission electron microscopy before the protein expressions of microtu?bule-associated protein 1 light chain 3 (LC3) and Beclin1 in brain tissue were analyzed by Western blot?ting assay. RESULTS Intracerebroventricular injection of Aβ25-35 could reduce the total distance from (3984±321)cm to (2790±306)cm and extend central grid residence time from (3.6±1.2)s to (8.8±2.9)s in the open-field test. The escape latency of water maze also increased from (22.0 ± 1.9)s to (38.8 ± 2.2)s. Autophagic vacuoles or late autophagic vacuoles and increased Beclin1 and LC3 and protein level were observed in the hippocampus after Aβ25-35 injection. Intraperitoneal injection of Baicalin 50 and 100 mg · kg-1 for fifteen consecutive days extended the total distance in open-field test to (3705 ± 337)cm and (3968 ± 448)cm, respectively, while the central grid residence time was reduced to (5.6 ± 1.8)s and (3.9±1.5)s, respectively. The total time taken to reach the platform in water maze test was reduced to (28.6± 1.9)s, (22.9 ± 1.7)s. Mitochondrial swelling, vacuolar membrane structure or autophagic vacuoles were visible in the hippocampus. LC3 and Beclin1 protein expression was significantly up-regulated(P<0.01). CONCLUSION Baicalin shows protective effect against Aβ25-35 induced learning and memory deficits, and this effect may be related to the activation of autophagy in the mouse hippocampus.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Effect of H. pylori on the expression of CCAAT enhancer binding protein α and Cx43 and its role in gastric carcinogenesis.
Li ZHOU ; Canxia XU ; Tingzi HU ; Xiaoming LIU ; Jing XIAO ; Ling LUO ; Xiaoxia JIANG
Journal of Central South University(Medical Sciences) 2016;41(7):700-706
OBJECTIVE:
To explore the effect of H. pylori on the expression of CCAAT enhancer binding protein α (C/EBPα) and connexin 43 (Cx43) in gastric carcinogenesis.
METHODS:
Different gastric mucosal epithelial cell lines (GES-1 cells, AGS cells and SGC-7901 cells) were cultured. A total of 6 cases of chronic non-atrophic gastritis tissues, 12 cases of gastric precancerous lesions tissues and 12 cases of gastric cancer tissues were collected under endoscopy. The expression of C/EBPα and Cx43 mRNA in the above-mentioned cells and tissues was detected by real-time PCR. The GES-1 cells and East Asian CagA+ H. pylori strains were co-cultured for 24 and 48 h as an experimental group, and those cell lines without H. pylori infection were cultured for 24 and 48 h as a control group. Real-time PCR and Western bolt were used to detect the expression of mRNA and proteins of C/EBPα and Cx43 in GES-1 cells, respectively.
RESULTS:
The expressions of C/EBPα and Cx43 mRNA in the AGS and SGC-7901 cells were lower than those in GES-1 cells (all P<0.05), and both of them decreased more profoundly in the SGC-7901 cells than those in the AGS cells (both P<0.05). The expressions of C/EBPα and Cx43 mRNA were lower in the gastric cancer tissues than those in the chronic non-atrophic gastritis tissues (both P<0.05) and gastric precancerous lesion tissues (both P<0.05). The C/EBPα expression was positively correlated with Cx43 expression (gastric precancerous lesion tissues: r=0.679, gastric cancer tissues: r=0.792; both P<0.05). Compared with the control group, the expressions of C/EBPα and Cx43 mRNA and protein in the experimental group were decreased at 24 and 48 h after culture (both P<0.05), which were lower at 48 h than those at 24 h (both P<0.05).
CONCLUSION
H. pylori infection can down-regulate the expressions of C/EBPα and Cx43 on gastric epithelial cells, which may be associated with gastric carcinogenesis.
CCAAT-Enhancer-Binding Protein-alpha
;
Cell Line
;
Cell Transformation, Neoplastic
;
Connexin 43
;
Down-Regulation
;
Gastric Mucosa
;
Helicobacter Infections
;
Helicobacter pylori
;
Humans
;
RNA, Messenger
;
Real-Time Polymerase Chain Reaction
;
Stomach Neoplasms