1.Expressions of HMGB1mRNA and NF-?B in lung injury induced by intestinal ischemia-reperfusion in rats and protective effects of polydatin
Journal of Chongqing Medical University 1987;0(01):-
Objective:To evaluate the activity of nuclear factor kappaB(NF-?B)and the gene expression of high mobility group box 1(HMGB1)in lung injury induced by intestinal ischemia-reperfusion(IIR),and to investigate the protective effect of polydatin(PD)in this lung injury.Methods:Fifty-four male Sprague-Dawley rats weighing 200~250 g were randomly divided into control group,IIR group(45 min intestinal ischemia with 0.5 h or 2 h or 6 h reperfusion)and PD group [IIR with PD(10 mg/kg)treatment].The level of pulmonary myeloperoxidase(MPO)was detected by colorimetric method,the expressions of NF-?B and ICAM-1 by immuneochemistry and that of pulmonary HMGB1mRNA by RT-PCR respectively.Results:Lung injury induced by IIR was characterized by pathological damage of edema,hemorrhage and inflammatory cell infiltration.Compared with control group,pulmonary W/D and MPO increased significantly(P
2.Design of hospital modernization evaluation based on capability development
Lulu ZHANG ; Tingfang LIU ; Zuxing YANG
Chinese Journal of Hospital Administration 1996;0(02):-
Objective To construct a framework for hospital modernization evaluation based on capability development. Methods In accordance with the theories for the sustainable development of the hospital and the results in the research on the development mechanism of the capability-oriented hospital and giving consideration both to the development level of the hospital and the driving force of its internal development, a framework for hospital modernization evaluation was designed from both the horizontal and vertical dimensions. Results A multidimensional, multilevel, and multi-index framework for hospital modernization evaluation was constructed. Conclusion The framework for hospital modernization evaluation is capable of evaluating hospital development from different dimensions and levels and reflecting the modernization level of the hospital and the mechanism of its internal driving force, thus more effectively guiding hospital modernization.
3.Application of tracer methodology for hospital assessment and continuous quality improvement
Xingguo ZHANG ; Tingfang LIU ; Quansen YANG ; Feng YUERAO ; Kuifen MA
Chinese Journal of Hospital Administration 2011;27(9):691-694
The paper described the basic theory and methods of tracer methodology. By means of case study, case tracing and system tracing, the authors applied this methodology in review or appraisal work in such aspects as priority focus process, priority focus content, clinical service team, appraisal process, and tracing pathways. All these aim at promoting continuous improvement of the quality of care.
4.Experimental study on the healing effect of breviscapine injection on deep partial thickness burn wound
Tingfang YANG ; Huiqing XIE ; Hua LIAO ; Hejie GU ; Haobo CHEN
Journal of Chinese Physician 2012;14(9):1208-1210
ObjectiveTo observe the healing effect of deep partial thickness burns by the injecting of breviscapine and discuss the possible mechanisms. Methods A rat model of deep partial thickness burns was designed,and was injected with breviscapine.The control group was injected with normal saline.The healing time of burn wound of the two groups was recorded,respectively.Seven days later,the tissues of bum wound of each group were extracted and the contents of hydroxyproline,collagenase-1,nitrogen monoxidum,erythrocuprein,and malonaldehyde that were contained in each extracts were measured.The results of each group were statistically analyzed.ResultsThe healing time of burn wound of the experimental group was [ ( 12 ± 1.428 ) days ],which was significantly shorter than the control group [ ( 14.75 ±1.291 )days] ( P <0.05).The contents of hydroxyproline[ (3.17 ± 1.136) mg/g],collagenase-1 [ ( 1.28± 0.651 ) mg/g ],nitrogen monoxidum [ ( 2.62 ± 0.30 ) μmol/gprot ],and erythrocuprein [ ( 221.25 ±25.94) U/mgprot ] in the experimental group were all higher than the control group [ (7.32 ± 2.173 )mg/g,(5.38 ±0.363) mg/g,(7.28 ± 0.40) μmol/gprot,(296.36 ± 29.29) U/mgprot ] ( P < 0.05 or P <0.01 ).However,the content of malonaldehyde [ (6.36 ± 0.93 ) nmol/mgprot ] was lower than the control group [ ( 1.25 ± 0.59) nmoL/mgprot ] ( P < 0.05 ).ConclusionsThe breviscapine injection can decurtate the healing time of deep partial thickness bums and it may be related to the extension of blood vessel,improvement of microcirculation,elimination of oxygen free radical,and degradation of lipid peroxidation.
5.Detecting Controlling and Driving System for a New Kind Tissue Engineering Bioreactor
Peng ZHONG ; Hua HUANG ; Chengkai YANG ; Tingfang ZHANG
Space Medicine & Medical Engineering 2006;0(01):-
Objective Horizontal rotating bioreactor is a kind of advanced bioreactor,which is the basic and important facility in tissue engineering.In this paper,we developed a controlable horizontal rotating bioreactor system,which can supple choiceness environment condition for cells culture.Methods System used PWM modulation to drive DC-motor,used sensor to detect and control the temperature of bioreactor reactor,and the system connected with PC to remote watch test and control.The system primarily achieved distributed control.Results The biology characteristic of the cells that were cultivated by this system improved greatly.Conclusion This practices of realization controlable horizontal rotating bioreactor system have bigger value in applications.
6.Treatment of complex acetabular fractures through supra-ilioinguinal approach by the use of 3D printing technique
Kaifang CHEN ; Desheng DUAN ; Zekang XIONG ; Fan YANG ; Tingfang SUN ; Yanhui JI ; Sheng YAO ; Xiaodong GUO
Chinese Journal of Orthopaedics 2017;37(13):786-792
Objective To investigate the clinical outcomes in the treatment of complex acetabular fractures through a single supra-ilioinguinal approach after the application of preoperative 3D printing and rapid prototyping simulating the operative procedure.Methods From January 2013 to January 2016,24 cases of complex pelvic and acetabular fractures in our hospital were retrospectively analyzed.Among them 18 cases were male and 6 were female.The average age was 39.2+±13.8 years (range,24-68 years).According to Letoumel-Judet's classification,there were 6 cases of transverse,4 cases of T shaped,4 cases of combined anterior column and posterior hemi-transverse (ACPHT) and 10 cases of 2-column fractures.The time from injured to operation averaged 9 days (range,4-18 days).Before operation,pelvic AP view,three-dimensional CT as well as CTA of iliac blood vessels was taken routinely in all cases.The CT and CTA scan data were then imported into Mimics software for 3D reconstruction.Surgical simulation and optimal placement of internal fixations were performed on computer.After that,the individual simulated model of the pelvis was printed by the use of 3D printing and rapid prototyping technique.The order of reduction,selection and optimal position of the implants were determined.The plates were bent before operation and the length and direction of the screws were recorded.A uniform supra-ilioinguinal approach was used in all cases.Results The length of incision averaged 9 cm (range,8-13 cm).The operative time average 130 min (range,90-220 min).The blood loss averaged 600 ml (range,300-1 500 ml).Once a satisfactory reduction was obtained,single placement of the plates was achieved.In accordance with the preoperative plan,the plates were perfectly fitted to the bone surface.The 24 patients were followed for an average time of 18.3 months (range,15-30 months).The fractures healed in all cases.The average healing time was 4.2 months (range,3-6 months).According to Matta criteria,there were 16 cases of excellent,6 cases of good,2 cases of poor and the excellent rate was 91.7% (22/24).The average modified Merle d'Aubigne score was 16.5 (range,13-18).The functional outcome was excellent in 13 cases,good in 6 cases and poor in 5 cases.The excellent rate of hip functions was 79.2% (19/24).There were 2 cases of femoral lateral cutaneous nerve injury (recovered one month later) and another 1 case of fat liquefaction of the incision happened three days postoperatively (the wound healed completely after several dressing changes).No inguinal hernia or abdominal wall hemias was found.No other postoperative complications was found.Conclusion The application of 3D printing and rapid prototyping technique allows preoperatively simulating reduction in vitro,determining the optimal position of the implants,bending the plates and measuring the length of the screws in advance,which could largely reduce the operative time,intraoperative blood loss and occurrence of postoperative complications.Adopting supra-ilioinguinal approach for the treatment of complex acetabular fractures with a small incision and less trauma,a full exposure could be obtained,so the reduction and fixation of the anterior,posterior and middle column (also named pubo-ischiatic column) could be completed in a direct visualization,resulting in a satisfactory clinical outcomes.
7.Expression of FOXO1 in Liver Cancer and Its Prognostic Significance: An Analysis Based on TCGA
Tingfang YANG ; Li WANG ; Yong ZHANG
Cancer Research on Prevention and Treatment 2021;48(8):774-781
Objective To investigate the expression and prognostic value of FOXO1 gene in liver cancer tissues based on TCGA and HPA databases. Methods The RNA-seq data of FOXO1 gene in liver cancer were downloaded from TCGA. The difference of FOXO1 gene expression between tumor and adjacent tissues was obtained via R software. The correlation between FOXO1 and clinicopathological features of liver cancer patients was analyzed. Survival analysis was carried out to evaluate the prognostic significance of FOXO1 gene expression in liver cancer patients. Univariate and multivariate Cox analyses were performed to explore prognostic factors. The correlation between FOXO1 expression and TIICs in tumor microenvironment was performed by CIBERSORT. KEGG pathways enrichment analysis was performed for the potential function of FOXO1 gene in liver cancer. Results FOXO1 was downregulated in liver cancer tissues compared with normal tissues (
8.Combined acetabular quadrilateral surface plates for the treatment of both column fractures
Kaifang CHEN ; Fan YANG ; Xiaodong GUO ; Zekang XIONG ; Sheng YAO ; Fengzhao ZHU ; Deepak DREPAUL ; Tingfang SUN ; Yanhui JI
Chinese Journal of Orthopaedics 2018;38(5):295-300
Objective To explore the clinical effectiveness and reliability of combined acetabular quadrilateral surface plates for the treatment of both column fractures.Methods From June 2016 to August 2017,data of 15 cases with acetabular both column fractures who were treated in our department were retrospectively analyzed.Among them 9 cases were male and 6 were female.The mean age was 42.8 years (range,26-68 years).All cases were both column fractures according to the LetournelJudet's classification,including 4 cases combined with posterior wall fracture.Before operation,the pelvic CT thin layer scanning data of patients were collected in DICOM format,and then the data were imported to print the simulated model by 3D printing technology in order to understand the characteristics of fracture directly.The contralateral half pelvis was mirror printed in order to simulate the placement of combined quadrilateral surface plates and preshape all plates.During operation,infrapectineal main plate,pubo-ischiatic plate and ilio-ischiatic plate were placed consequently to fix the anterior column,"middle column" and posterior column respectively.The pubo-ischiatic and ilio-ischiatic plates were combined with the main plate.All cases were operated by supra-ilioinguinal approach.Results The average incision length was 11 cm (range,9-13 cm).The average operative time was 150 min (range,100-240 min).The average blood loss was 850 ml (range,600-1500 ml).Once reduction was obtained,plates could be placed easily and adhere to bone surface well.The quality of postoperative fracture reduction was evaluated according to Matta standard,of which there were 9 cases excellent,4 cases good,and 2 cases poor,with an excellent rate of 86.7% (13/15).All patients were followed up for an average time of 10 months (range,6-12 months).At the latest follow-up,the average modified Merle d'Aubigne and Postel score was 16.4 (range,12-18),and there were 8 cases excellent,4 cases good,2 cases fair and 1 case poor,with an excellent rate of 80.0% (12/15).Conclusion For the treatment of acetabular both column fractures,the combined quadrilateral surface plates could resist the medial displacement of quadrilateral area,and on the other hand the total floating posterior column and ischium could be fixed firmly.At the same time,this plate system is a multi-dimensional framework fixation,which is more effective and safer with lower complications rate,resulting in a satisfactory clinical outcomes.
9.Empirical study of China's hospital management using methodology of World Management Survey
Hanqing ZHAO ; Yujie CUI ; Tingfang LIU ; Mengxiao WANG ; Yangyang HE ; Maorui YANG ; Guo'en LIU
Chinese Journal of Hospital Administration 2018;34(11):955-960
Objective To explore methods to measure the management level of Chinese hospitals in natural conditions of Chinese hospitals, for improvement of their operation efficiency. Methods The methodology of World Management Survey( WMS) was introduced, and the questionnaire was localized using expert consultation method. Double-blind telephone interviews were conducted to investigate the management level of Chinese hospitals in the four dimensions of standardized operation, performance monitoring, target setting and talent management. Results The management level of hospitals in China varied greatly from places. Among them, the hospital management scoring was found to range from 2. 50 to 2. 75 in most cases, averaging 2. 55. These hospitals scored relatively poor at the four specific management practices of hospital layout(2.48), performance communication(2.27), talents retention, and clarity and comparability of objectives(2. 45). Management level of a hospital was correlated to such factors as its history, ownership form, human capital and hospital size. Conclusions This study uses WMS methodology to quantify Chinese hospital management. The overall management level of Chinese hospitals is expected to improve with much gaps to cover. At this stage, it is imperative to solve the unbalanced and inadequate development of hospital management levels, among regions, hospital grades and forms of ownership.
10.The supra-pectineal quadrilateral surface buttress plate for the treatment of complex acetabular fractures
Kaifang CHEN ; Sheng YAO ; Yizhou WAN ; Lian ZENG ; Fengzhao ZHU ; Zekang XIONG ; Liang YANG ; Jinge ZHOU ; Tingfang SUN ; Xiaodong GUO
Chinese Journal of Orthopaedics 2020;40(5):294-301
Objective:To introduce a novel anatomical supra-pectineal quadrilateral surface buttress plate, and explore its advantages, disadvantages and clinical efficacy in the treatment of complex acetabular fractures.Methods:Data of eighteen cases of acetabular fractures treated in our department from March 2017 to March 2019were retrospectively analyzed. There were 15 males and 3 females with an average age of 49.6 years (range, 27-62 years). According to the Letournel-Judet’s classification, there were 3 cases of anterior column fractures (involving quadrilateral surface), 2 cases of "T" shaped, 8 of cases anterior column and posterior hemi-transverse (ACPHT) and 5 cases of double columns fractures. The time from injury to operation was 5-14 days (mean, 7 days). Before operation, all patients were taken pelvic anterior-posterior X-ray and CT scan. All patients were adopted supra-ilioinguinal approach and fixed by supra-pectineal quadrilateral surface buttress plate. Surgical time, intraoperative blood loss and postoperative complications were collected. After operations all patients were taken pelvic X-ray in anterior-posterior and Judet position, as well as CT scan. The radiographic quality of reduction was evaluated by Matta criteria and hip functions were evaluated by Matta Modified Merle d’Aubigné-Postel scoring system.Results:The average surgical time was 130 min (range, 100-200 min). The average blood loss was 560 ml (range, 400-900 ml). An additional shaping was unnecessary in 18 patients who were implanted with the anatomical supra-pectineal quadrilateral surface buttress plate and all patients were operated successfully. All patients were followed up for an average time of 9 months (range, 6-15 months). The quality of fracture reduction was evaluated according to Matta standard, of which there were 11 cases excellent, 4 cases good, and 3 cases poor, with an excellent rate of 83.3% (15/18). At the latest follow-up, the function of the hip joint was evaluated according to the Matta Modified Merle d’Aubigné-Postel scoring system for a mean of 15.8 scores (range, 12-18 scores), of which there were 10 cases excellent, 6 cases good, 2 cases fair, with an excellent rate of 88.9% (16/18). All patients recovered well, and there were 2 cases of lateral femoral cutaneous nerve injury postoperative who had recovered one month later. There was no other postoperative complications.Conclusion:The anterior and posterior column and quadrilateral surface could be stabilized simultaneously by the anatomical supra-pectineal quadrilateral surface buttress plate without intraoperative shaping. Moreover, it is more likely to obtain a satisfactory clinical outcome by using this special plate with lower complications and rigid fixation. Therefore, it is a kind of internal fixation method worthy of promotion in the treatment of complex acetabular fractures.