1.Design of the psychology tester based on ZigBee technology.
Chinese Journal of Medical Instrumentation 2012;36(5):350-353
OBJECTIVETo design a psychological state tester based on ZigBee wireless technology.
METHODSThrough analog circuit preprocessing, the heartbeat collected by the pulse sensor will be transformed into digital signal from analog signal, and then can be processed and displayed after transported to the personal computer through the Zigbee wireless communicate units. The data will be retrieval and playback for the measurement of psychology.
RESULTSThe experiments show that the device is able to acquire the pulse wave of the human body in real-time, at the same time, through the ZigBee wireless network, it can accomplish real-time, secure and reliable communications, and it also can be used in the research of testing the mental state of the individual.
CONCLUSIONThrough the application of the ZigBee communicate technology; the psychology tester can collect the pulse signal to reflect the individual's mental state in different conditions. So it will be applicable to a wide range of psychology measurement and other areas.
Computer Communication Networks ; instrumentation ; Equipment Design ; Heart Rate ; Humans ; Psychological Tests ; Psychology, Clinical ; instrumentation ; Signal Processing, Computer-Assisted ; instrumentation ; Wireless Technology
2.Effect of contrast media on renal function in patients with cerebrovascular disease complicated by diabetes mellitus after receiving interventional treatment
Zaigang LÜ ; Linna WANG ; Xiaohui CHEN ; Ligong ZHANG ; Mengfei ZHONG ; Haiting LI ; Zhijie YANG ; Min LI ; Tianping TANG ; Zongen GAO
Journal of Interventional Radiology 2018;27(3):277-280
Objective To evaluate the effect of contrast medium on the renal function in patients with cerebrovascular disease accompanied by diabetes mellitus after receiving neuro - interventional therapy. Methods The clinical data of a total of 108 patients with cerebrovascular disease complicated by diabetes mellitus type 2, who were treated with neuro - interventional therapy during the period from March 2013 to March 2016, were retrospectively analyzed. The contrast dose used in interventional procedures was less than 250ml in each patient. The preoperative and 24 h -postoperative serum creatinine (sCr), serum cystatin C (Cys C) levels were determined, and based on the modification of dietary renal disease (MDRD) equation and Larsson equation the estimated glomerular filtration rates (eGFR) were separately calculated. Results Compared with preoperative values, the 24 h - postoperative mean sCr and Cys C levels were increased significantly (P=0. 001, P=0. 015 respectively), while the average eGFR rates were remarkably decreased (P< 0. 000 1 by using MDRD equation, and P=0. 021 by using Larsson equation). No kidney damage that needed to be treated occurred in all patients. Conclusion The contrast dose used in neuro - interventional procedures can cause decline of renal function in patients with type 2 diabetes mellitus. The combined determination of sCr and Cys C levels is helpful for the detection of contrast - induced changes in renal function as early as possible. The use of conventional dose of contrast agent in neuro - interventional procedures is safe for patients with type 2 diabetes mellitus. (J Intervent Radiol, 2018, 27:277-280)
3. Identification of the long noncoding RNA_ AK096792 in cord blood as a clinical predictor for early diagnosis of bronchopulmonary dysplasia in preterm infants
Yan ZHANG ; Tianping BAO ; Xiaotong SONG ; Yunjia HAO ; Zhaofang TIAN ; Chen SONG ; Yazhou SUN ; Weiwei WANG ; Bin ZHOU ; Chenghe TANG ; Jiaqin WANG
Chinese Journal of Applied Clinical Pediatrics 2018;33(14):1075-1078
Objective:
To investigate the feasibility of long noncoding RNA (lncRNA)_AK096792 as a clinical predictor of bronchopulmonary dysplasia (BPD) in preterm infants.
Methods:
All the cord blood(2-5 mL) of very low birth weight (VLBW) preterm infants born in Huai′an First Hospital Affiliated to Nanjing Medical University were collected from December 1, 2015 to December 1, 2017.Moreover, the peripheral blood(2 mL) of those VLBW infants diagnosed with BPD was also collected.A total of 36 infants with BPD were collected.Another 36 cases of premature children with VLBW were chosen as control group according to random number table.The relative content of lncRNA_AK096792 in cord blood and peripheral blood was detected by using real-time quantitative PCR (qPCR). Additionally, the correlation of lncRNA_AK096792 levels between cord and peripheral blood of BPD infants was analyzed.The sensitivity and specificity of lncRNA_AK096792 for BPD were analyzed by using receiver operating curve test.
Results:
(1)LncRNA_AK096792 was a common, evolutionarily conserved, non-coding RNA present in both mouse and human.(2) The expression level of lncRNA_AK096792 in peripheral blood was significantly higher than that in cord blood in BPD group[(463.3±352.0)%