1.Computerized quality control of radioimmunoassay in Korea.
June Key CHUNG ; Sung Soo KOONG ; Myung Hae LEE ; Soo Kyo CHUNG ; Myung Chul LEE ; Bo Youn CHO ; Choon Yul KIM ; Chang Soon KOH ; Soo Sung PARK
Journal of Korean Medical Science 1988;3(3):117-121
Automated data processing and quality control of radioimmunoassays offer not only increased speed but also a more thorough and statistically rigorous analysis of results. An external quality assessment scheme for serum thyroxine, triiodothyronine and thyroid stimulating hormone (TSH) assays was performed in five nuclear medicine laboratories in Korea to compare with the assay performances of the World Health Organization Radioimmunoassay Program. The required radioimmunoassay kits were supplied through the International Atomic Energy Agency (IAEA). We have determined the weighted root mean squared error, and variance ratio as the indices of standard curve and also the average batch coefficient of variation (ABCV) as the parameters of response error relationship curve and precision profile. There was a good fit for the triiodothyronine assay, but 3 of 5 laboratories showed possible bad fit in the T4 and TSH assay systems. The ABCV was less than 5 percent for the T3 and T4 assay system, however for the TSH system, only 1 laboratory showed the ABCV value of less than 5 percent. We have also calculated the within batch variation (drift) and between laboratory variations.
*Automatic Data Processing
;
Humans
;
Radioimmunoassay/*standards
;
Thyroid Hormones/*analysis
2.Computerized quality control of radioimmunoassay in Korea.
June Key CHUNG ; Sung Soo KOONG ; Myung Hae LEE ; Soo Kyo CHUNG ; Myung Chul LEE ; Bo Youn CHO ; Choon Yul KIM ; Chang Soon KOH ; Soo Sung PARK
Journal of Korean Medical Science 1988;3(3):117-121
Automated data processing and quality control of radioimmunoassays offer not only increased speed but also a more thorough and statistically rigorous analysis of results. An external quality assessment scheme for serum thyroxine, triiodothyronine and thyroid stimulating hormone (TSH) assays was performed in five nuclear medicine laboratories in Korea to compare with the assay performances of the World Health Organization Radioimmunoassay Program. The required radioimmunoassay kits were supplied through the International Atomic Energy Agency (IAEA). We have determined the weighted root mean squared error, and variance ratio as the indices of standard curve and also the average batch coefficient of variation (ABCV) as the parameters of response error relationship curve and precision profile. There was a good fit for the triiodothyronine assay, but 3 of 5 laboratories showed possible bad fit in the T4 and TSH assay systems. The ABCV was less than 5 percent for the T3 and T4 assay system, however for the TSH system, only 1 laboratory showed the ABCV value of less than 5 percent. We have also calculated the within batch variation (drift) and between laboratory variations.
*Automatic Data Processing
;
Humans
;
Radioimmunoassay/*standards
;
Thyroid Hormones/*analysis
3.Establishment of Trimester-Specific Reference Intervals for Thyroid Hormones in Korean Pregnant Women.
Hee Won MOON ; Hee Jung CHUNG ; Chul Min PARK ; Mina HUR ; Yeo Min YUN
Annals of Laboratory Medicine 2015;35(2):198-204
BACKGROUND: Establishment of trimester- and assay-specific reference intervals for every population is recommended. The aim of this study was to establish a trimester- and assay-specific reference interval for thyroid-stimulating hormone (TSH) and free thyroxine (FT4) in Korean pregnant women. METHODS: From April 2012 to December 2012, 531 pregnant women receiving prenatal care and 238 age-matched, non-pregnant women were enrolled in this study. After excluding patients with pregnancy-associated complications or thyroid-specific autoantibody, 465 pregnant and 206 non-pregnant women were included. Non-parametric analysis (2.5-97.5th percentile) was performed to determine the reference interval. Levels of TSH and FT4 were determined by electrochemiluminescence immunoassay (Elecsys thyroid tests, Roche Diagnostics, Germany). RESULTS: The TSH reference intervals were 0.01-4.10, 0.01-4.26, and 0.15-4.57 mIU/L for the first, second, and third trimester, respectively. From the first trimester to the third trimester, the median TSH levels showed a significantly increasing trend (P<0.0001). The FT4 reference intervals were 0.83-1.65, 0.71-1.22, and 0.65-1.13 ng/dL for the first, second, and third trimester, respectively, showing a significantly decreasing trend (P<0.0001). CONCLUSIONS: Establishing trimester-specific reference intervals in pregnant women is essential for accurate assessment of thyroid function. Our population-specific and method-specific reference intervals will be useful for screening Korean pregnant women for thyroid disease.
Adult
;
Asian Continental Ancestry Group
;
Case-Control Studies
;
Female
;
Humans
;
*Immunoassay/standards
;
Luminescent Measurements
;
Pregnancy
;
Pregnancy Trimesters
;
Prenatal Care
;
Reference Values
;
Republic of Korea
;
Thyroid Hormones/*analysis/standards
;
Thyroxine/*analysis/standards