1.Research of the Thrombus Protection Device During the Cerebral Vascular Interventional Therapy.
Chinese Journal of Medical Instrumentation 2016;40(1):35-37
This article introduces a cerebral thrombus protection device for the cerebral interventional treatment, also introduces the principle, design and manufacturing process of the device, and confirmes the effectiveness in vitro experiment.
Equipment Design
;
Humans
;
Thrombosis
;
prevention & control
2.Removal of Shield Needles from Graphene Oxide Thrombus and Preparation.
Yuting YANG ; Yuanjian ZHONG ; Lichun ZHAO ; Yuanbo SONG ; Li YU
Chinese Journal of Medical Instrumentation 2021;45(5):492-496
Atherosclerosis is a chronic inflammatory disease commonly seen in clinical practice. It can lead to thickening of vascular intima, occlusion of lumen stenosis and thrombosis, leading to angina pectoris, hypertension, myocardial infarction and other diseases, posing a serious threat to human life and health. This study provides a method for removing shield needles from graphene oxide thrombus and its preparation. The graphene oxide shield needle mainly includes flexible rotating shaft, radial flexible rod, rotating needle, adsorption main pipe and dosing main pipe, laser measuring device, high definition camera and other structures, which has the following advantages:firstly, it achieves multi-angle rotation grinding thrombosis, precise rotation grinding, avoids vascular damage and infection; secondly, thrombolytic drugs can be applied in the process of rotary grinding and small thrombus can be adsorbed to effectively avoid secondary embolization of blood vessels; thirdly, it a coating of graphene oxide on a rotating needle, which protects against bacteria and infection. This study has practical reference value for the development of thrombotherapy and the application of graphene in the medical field.
Adsorption
;
Graphite
;
Humans
;
Needles
;
Thrombosis/prevention & control*
3.A new approach for improving antithrombogenicity in centrifugal pump.
Kunxi QIAN ; Pei ZENG ; Weimin RU ; Haiyu YUAN
Journal of Biomedical Engineering 2003;20(3):534-536
For long-term application of the rotary pumps, it is necessary to solve the problems of bearing wear and thrombosis along the bearing. Currently, many investigators choose the magnetic bearing to realize zero-friction and no contact between the rotor and stator; the former avoids the mechanical wear and the latter eliminates the possibility of thrombus formation. We tried and found that it is difficult to apply a magnetic bearing to rotary pump without disturbing its simplicity, reliability and implantable; therefore, we have developed a much simpler and much more creative approach to achieving the same results. Instead of the sliding bearing, a rolling bearing has been devised for the pump; its friction is about 1/15 of the sliding bearing. Furthermore, a wear-proof material of ultra-high-molecular weight polythene has been adopted in making the rollers, their anti-wear property in 8 times better than that of metal. Thereby, the service life of the bearing has extended to several years. For preventing the thrombus formation along the bearing, the impeller reciprocation axially as the impeller changes its rotating speed periodically to produce a pulsatile flow. The reciprocation is a result of the effects of a magnetic force between the motor rotor and stator, and a hydraulic force between the blood flow and the impeller. Similar to piston pump, the oscillating impeller can make the blood in and out of the bearing, resulting in wash-out once a circle. This is obviously beneficial to preventing thrombosis along the bearing and in the pump. The endurance tests with saline of this novel pump demonstrated a durability of the device. It promises to be able to assist the circulation of the patients permanently and to be able to replace the heart transplantation in the future.
Heart-Assist Devices
;
Magnetics
;
instrumentation
;
Prosthesis Design
;
Thrombosis
;
prevention & control
4.Omega-3 fatty acids and non-communicable diseases.
Chinese Medical Journal 2003;116(3):453-458
OBJECTIVETo review the relation between dietary omega-3 polyunsaturated fatty acids (omega-3 PUFA) and non-communicable diseases.
METHODData were collected from scientific journals and conference publications, MEDLINE (1979 - 2002) and current content which included 68 prospective, cross-sectional, case control and dietary-intervention studies. Scientific paper selections were based on the association between omega-3 PUFA and non-communicable diseases.
RESULTSomega-3 PUFA has beneficial effects on increasing heart rate variability, decreasing the risk of stroke, reducing both systolic and diastolic blood pressure, insulin resistance and glucose metabolism. Long chain omega-3 PUFA has anti-cancer and anti-inflammatory activities. omega-3 PUFA has also been reported to have a beneficial effect on attention-deficit/hyperactivity disorder and schizophrenia, and may be effective in managing depression in adults.
CONCLUSIONSResults from epidemiological and dietary intervention studies have shown that omega-3 PUFA represent powerfully a class of bioactive compounds and that dietary intake of omega-3 PUFA plays a critical role in human health in relation to non-communicable diseases.
Diabetes Mellitus ; therapy ; Fatty Acids, Omega-3 ; administration & dosage ; pharmacology ; Humans ; Hypertension ; prevention & control ; Inflammation ; prevention & control ; Lipids ; blood ; Mental Disorders ; therapy ; Neoplasms ; prevention & control ; Thrombosis ; prevention & control
7.Pathogenesis and management of hemorrhage and thrombosis in plasma cell dyscrasias.
Journal of Experimental Hematology 2010;18(3):809-815
Unexpectedly high rates of venous thromboembolic events (VTE) induced by highly effective immune modulating drugs thalidomide and lenalidomide for treatment of multiple myeloma have focused attention on the incidence and underlying pathophysiology of VTE in patients with plasma cell dyscrasias, and on thromboprophylaxis approaches. While bleeding complications are relatively uncommon in the patients with lymphoproliferative disorders, acquired von Willebrand syndrome, typically occurring in the patients with monoclonal gammopathy of unknown significance, and acquired coagulopathies associated with primary amyloidosis can present with haemorrhagic complications and both are challenges to the management. This review highlights these important haemostasis-related complications of plasma cell dyscrasias and provides an overview of other uncommon bleeding and thrombotic events that can affect diagnosis and therapeutic management of clonal plasma cell disorders. Due to the infrequency of most these haemostasis complications, available information is typically based on retrospective cases or series analysis.
Hemorrhage
;
etiology
;
pathology
;
therapy
;
Humans
;
Paraproteinemias
;
complications
;
pathology
;
Thrombosis
;
etiology
;
pathology
;
prevention & control
8.Development of an apparatus for preventing deep vein thrombosis.
Xian-ming CHEN ; Chun-ao WEN ; Da-qiang GU
Chinese Journal of Medical Instrumentation 2005;29(5):331-333
A kind of intermittent pneumatic compression (IPC) apparatus is developed to prevent deep vein thrombosis (DVT),which is based on the theory of occurrence and prevention of the DVT and AT89C52 micro-controller. This paper introduces its principle, composition of electromechanical system and the software design. The apparatus has showed its characteristics of easy operation, high intelligence and high reliability.
Equipment Design
;
Physical Therapy Modalities
;
instrumentation
;
Software
;
Thrombolytic Therapy
;
instrumentation
;
Venous Thrombosis
;
prevention & control
9.Effect of standardized PICC training and management on the clinical effect and complication of catheterization.
Jinghui ZHANG ; Siyuan TANG ; Lianxiang HE ; Wenfeng CHEN ; Pinglan JIANG ; Yuanping HU ; Hua CHEN
Journal of Central South University(Medical Sciences) 2014;39(6):638-643
OBJECTIVE:
To determine the clinical effect of standardized training and management of peripherally inserted central catheter (PICC) and catheter-related complications.
METHODS:
A total of 610 patients were divided into a control group and an observation group, the control group (n=300) were catheterized by trainees who received "short-term intensive training", the observation group (n=310) by "system standardized training and management". The clinical efficacy of catheterization and the rate of catheter-related complications were compared.
RESULTS:
There was significant difference in the one-time puncture success rate, one-time cannulation success rate, the time for operation and the pain score between the 2 groups (all P<0.01), and there was also significant difference in the occurrence of catheter extrusion, plug, arrhythmia, catheter-related thrombosis, phlebitis, puncture point effusion and catheter-related infection between the 2 groups (all P<0.05).
CONCLUSION
Standardized PICC training and management can improve the effect of catheterization and reduce the incidence of PICC-related complication.
Catheter-Related Infections
;
prevention & control
;
Catheterization, Peripheral
;
methods
;
Humans
;
Incidence
;
Inservice Training
;
Thrombosis
10.Numerical simulation and performance analysis of mixed flow blood pump.
Jiping LUO ; Diangui HUANG ; Bin XU
Journal of Biomedical Engineering 2020;37(2):296-303
The high rotational speed of the axial flow blood pump and flow separation of the centrifugal blood pump are the main causes for blood damage in blood pump. The mixed flow blood pump can effectively alleviate the high rotational speed and the flow separation. Based on this, the purpose of this study is to explore the performance of the mixed blood pump with a closed impeller. A mixed flow blood pump with closed impeller was studied by numerical simulation in this paper. The flow field characteristics and the pressure distribution of this type of blood pump were analyzed. The hydraulic performance of the blood pump and the possible damages to red blood cells were also discussed. At last, pump performance was compared with the mixed flow blood pump with semi-open impeller. The results show that the mixed flow blood pump with close impeller studied in this paper can operate safely and efficiently with a good performance. The pump can reach the pressure head of 100 mmHg at 5 L/min mass flow rate. Flow in the blood pump is uniform and no obvious separation or vortex occurs. Pressure distribution in and on the impeller is uniform and reasonable, which can effectively avoid the thrombosis of blood. The average mean value of hemolysis index is 4.99 × 10 . The pump has a good biocompatibility. Compared with the mixed flow blood pump with semi-open impeller, the mixed flow blood pump with closed impeller has higher head and efficiency, a smaller mean value of hemolysis index prediction, a better hydraulic performance and the ability to avoid blood damage. The results of this study may provide a basis for the performance evaluation of the closed impeller mixed flow blood pump.
Computer Simulation
;
Equipment Design
;
Heart-Assist Devices
;
Hemolysis
;
Humans
;
Thrombosis
;
prevention & control