1.Removing Lipemia in Serum/Plasma Samples: A Multicenter Study.
María José CASTRO-CASTRO ; Beatriz CANDÁS-ESTÉBANEZ ; Margarita ESTEBAN-SALÁN ; Pilar CALMARZA ; Teresa ARROBAS-VELILLA ; Carlos ROMERO-ROMÁN ; Miguel POCOVÍ-MIERAS ; José Angel AGUILAR-DORESTE
Annals of Laboratory Medicine 2018;38(6):518-523
BACKGROUND: Lipemia, a significant source of analytical errors in clinical laboratory settings, should be removed prior to measuring biochemical parameters. We investigated whether lipemia in serum/plasma samples can be removed using a method that is easier and more practicable than ultracentrifugation, the current reference method. METHODS: Seven hospital laboratories in Spain participated in this study. We first compared the effectiveness of ultracentrifugation (108,200×g) and high-speed centrifugation (10,000×g for 15 minutes) in removing lipemia. Second, we compared high-speed centrifugation with two liquid-liquid extraction methods—LipoClear (StatSpin, Norwood, USA), and 1,1,2-trichlorotrifluoroethane (Merck, Darmstadt, Germany). We assessed 14 biochemical parameters: serum/plasma concentrations of sodium ion, potassium ion, chloride ion, glucose, total protein, albumin, creatinine, urea, alkaline phosphatase, gamma-glutamyl transferase, alanine aminotransferase, aspartate-aminotransferase, calcium, and bilirubin. We analyzed whether the differences between lipemia removal methods exceeded the limit for clinically significant interference (LCSI). RESULTS: When ultracentrifugation and high-speed centrifugation were compared, no parameter had a difference that exceeded the LCSI. When high-speed centrifugation was compared with the two liquid-liquid extraction methods, we found differences exceeding the LCSI in protein, calcium, and aspartate aminotransferase in the comparison with 1,1,2-trichlorotrifluoroethane, and in protein, albumin, and calcium in the comparison with LipoClear. Differences in other parameters did not exceed the LCSI. CONCLUSIONS: High-speed centrifugation (10,000×g for 15 minutes) can be used instead of ultracentrifugation to remove lipemia in serum/plasma samples. LipoClear and 1,1,2-trichlorotrifluoroethane are unsuitable as they interfere with the measurement of certain parameters.
Alanine Transaminase
;
Alkaline Phosphatase
;
Aspartate Aminotransferases
;
Bilirubin
;
Calcium
;
Centrifugation
;
Creatinine
;
Glucose
;
Hyperlipidemias*
;
Laboratories, Hospital
;
Liquid-Liquid Extraction
;
Methods
;
Potassium
;
Sodium
;
Spain
;
Transferases
;
Ultracentrifugation
;
Urea