1.Role of the O-arm and Computer-assisted Navigation of Safe Screw Fixation in Children with Traumatic Rotatory Atlantoaxial Subluxation.
Walid ATTIA ; Tamer ORIEF ; Khaled ALMUSREA ; Mohamed ALFAWAREH ; Lahbib SOUALMI ; Yasser ORZ
Asian Spine Journal 2012;6(4):266-273
STUDY DESIGN: A retrospective analysis of 7 patients with traumatic rotatory atlanto-axial subluxation. OVERVIEW OF LITERATURE: Cases of traumatic rotatory atlantoaxial subluxation in children are difficult to be stabilized. Surgical challenges include: narrow pedicles, medial vertebral arteries, vertebral artery anomalies, fractured pedicles or lateral masses, and fixed subluxation. The use of O-arm and computer-assisted navigation are still tested as aiding tools in such operative modalities. PURPOSE: Report of clinical series for evaluation of the safety of use of the O-arm and computed assisted-navigation in screw fixation in children with traumatic rotatory atlantoaxial subluxation. METHODS: In the present study, 7 cases of rotatory atlantoaxial traumatic subluxation were operated between December 2009 and March 2011. All patient-cases had undergone open reduction and instrumentation using atlas lateral mass and axis pedicle screws with intraoperative O-arm with computer-assisted navigation. RESULTS: All hardware was safely placed in the planned trajectories in all the 7 cases. Intraoperative O-arm and computer assisted-navigation were useful in securing neural and vascular tissues safety with tough-bony purchases of the hardware from the first and only trial of application with sufficient reduction of the subluxation. CONCLUSIONS: Successful surgery is possible with using the intraoperative O-arm and computer-assisted navigation in safe and proper placement of difficult atlas lateral mass and axis pedicle screws for rotatory atlantoaxial subluxation in children.
Atlanto-Axial Joint
;
Axis, Cervical Vertebra
;
Child
;
Congenital Abnormalities
;
Humans
;
Imaging, Three-Dimensional
;
Retrospective Studies
;
Vertebral Artery
2.Guidewire Breakage: An Unusual Complication of Anterior Odontoid Cannulated Screw Fixation.
Tamer ORIEF ; Sharaf BIN-NAFISAH ; Khaled ALMUSREA ; Mohamed ALFAWAREH
Asian Spine Journal 2011;5(4):258-261
The preferred treatment of a type II odontoid fracture is anterior odontoid screw fixation to preserve the cervical spine range of movement. This case report describes an unusual complication of guidewire breakage during anterior odontoid cannulated screw fixation for a 52-year-old patient who presented with a type II odontoid fracture after a motor vehicle accident. The distal segment of the guidewire was bent over the tip of the cannulated odontoid screw and broke off during guidewire withdrawal. The three months follow-up computed tomography examination of the cervical spine showed acceptable screw placement, good odontoid process alignment with incomplete fusion, and no migration of the fractured segment of the guidewire. It is recommended that the guidewire be withdrawn once the cannulated screw is passed through the fractured site into the odontoid process and a new guidewire be used in each surgical procedure instead of been reused to avoid metal stress fatigue that can result in easy breakage.
Fatigue
;
Follow-Up Studies
;
Humans
;
Middle Aged
;
Motor Vehicles
;
Odontoid Process
;
Spine