1.High-grade culprit lesions are a common cause of ST-segment elevation myocardial infarction.
Michael LIANG ; Takashi KAJIYA ; Mark Y CHAN ; Edgar TAY ; Chi-Hang LEE ; Arthur Mark RICHARDS ; Adrian F LOW ; Huay Cheem TAN
Singapore medical journal 2015;56(6):334-338
INTRODUCTIONConventional knowledge holds that the majority of ruptured atherosclerotic plaques causing ST-segment elevation myocardial infarction (STEMI) are found in moderate stenoses that produce < 50% loss of arterial diameter. This study aimed to analyse the culprit lesions in patients who presented with STEMI and underwent primary percutaneous coronary intervention (PPCI) at our institution.
METHODSPatients who underwent PPCI between June 2008 and August 2010 at our institution were included in the analysis. Quantitative coronary angiography was performed for the culprit lesions immediately after antegrade flow was restored by thrombectomy, low-profile balloon predilatation or guidewire crossing.
RESULTSA total of 1,021 patients were included in the study. The mean age was 57 ± 12 years and 85.2% were male. Lesion measurement was done after coronary flow was restored by thrombectomy (73.1%), balloon dilatation (24.1%) and following guidewire passage across the lesion (2.8%). Mean minimal luminal diameter was 1.1 ± 0.5 mm, mean reference vessel diameter was 2.8 ± 0.6 mm, mean diameter stenosis was 61 ± 16% and mean lesion length was 16 ± 6 mm. Most (80.2%) of the culprit lesions had diameter stenoses > 50% (p < 0.01). Although balloon angioplasty was performed in 24.1% of the patients, the majority (64.2%) still had diameter stenoses > 50%. High-grade stenoses (> 50%) were more frequently observed in male patients (p = 0.04).
CONCLUSIONContrary to the existing paradigm, we found that most of the patients with STEMI in our institution had culprit lesions with diameter stenosis > 50%.
Adult ; Aged ; Angioplasty ; Angioplasty, Balloon, Coronary ; Constriction, Pathologic ; Coronary Angiography ; Coronary Vessels ; surgery ; Female ; Humans ; Male ; Middle Aged ; Percutaneous Coronary Intervention ; Plaque, Atherosclerotic ; complications ; Reference Values ; Retrospective Studies ; Rupture ; complications ; ST Elevation Myocardial Infarction ; etiology ; surgery ; Sex Factors ; Thrombectomy ; methods
2.In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents.
Takashi KAJIYA ; Hiroshi YAMAGUCHI ; Junichiro TAKAOKA ; Kengo FUKUNAGA ; Ryoichi ARIMA ; Akihiro MIYAMURA ; Toshiko NINOMIYA ; Nobuhiko ATSUCHI ; Yoshihiko ATSUCHI ; Mitsuyasu TERASHIMA ; Hideaki KANEDA ; Mitsuru OHISHI
Singapore medical journal 2019;60(1):48-51
INTRODUCTION:
The pathophysiology and mechanism of in-stent restenosis (ISR) after implantation of second-generation drug-eluting stents (DESs) are not fully clear. We compared the morphological characteristics of ISR between first- and second-generation DESs using frequency domain optical coherence tomography (OCT).
METHODS:
Patients who underwent follow-up coronary angiography (CAG) after first-generation (CYPHER™ and TAXUS™) and second-generation (Nobori®, PROMUS Element™, Resolute Integrity and XIENCE) DES implantations were examined. ISR was defined as lesions of over 50% diameter stenosis at follow-up CAG. Frequency domain OCT was performed at the time of revascularisation of ISR. Tissue morphology was assessed at minimum lumen area. OCT images of DESs at both early (≤ 1 year) and late (> 1 year) phase follow-up were compared.
RESULTS:
On qualitative OCT assessment, the ratios of homogeneous, layered, heterogeneous without-attenuation and heterogeneous with-attenuation morphologies were 57.1%, 17.1%, 20.0% and 5.7%, respectively, for second-generation DES ISR (n = 35), and 16.7%, 25.0%, 25.0% and 33.3%, respectively, for first-generation DES ISR (n = 36). At late phase follow-up, homogeneous morphology was significantly more common for second-generation DES ISR compared to first-generation DES ISR (first-generation: 8.0% vs. second-generation: 50.0%; p < 0.01) while heterogeneous with-attenuation morphology was significantly more common for first-generation DES ISR (first-generation: 44.0% vs. second-generation: 5.6%; p < 0.01).
CONCLUSION
Homogeneous tissue morphology was more frequently found for second-generation than first-generation DES ISR, especially in the late phase. This suggested that neointimal hyperplasia was the main mechanism in second-generation DES ISR, and that the neointima was stabilised, much like in bare metal stent implantation.
Aged
;
Constriction, Pathologic
;
pathology
;
Coronary Angiography
;
Coronary Restenosis
;
diagnostic imaging
;
pathology
;
Coronary Vessels
;
diagnostic imaging
;
pathology
;
surgery
;
Drug-Eluting Stents
;
adverse effects
;
Female
;
Humans
;
Incidence
;
Male
;
Metals
;
Middle Aged
;
Neointima
;
Retrospective Studies
;
Tomography, Optical Coherence