1.Intrathoracic anastomosis using handsewn purse-string suturing by the double-ligation method in laparo-thoracoscopic esophagectomy
Takamasa TAKAHASHI ; Yuji KANEOKA ; Atsuyuki MAEDA ; Yuichi TAKAYAMA ; Hiroki AOYAMA ; Takahiro HOSOI ; Kazuaki SEITA
Journal of Minimally Invasive Surgery 2023;26(2):64-71
Purpose:
In minimally invasive esophagectomy (MIE), it is important to reduce the rate of anastomotic leakage to ensure its safety. At our institute, the double-ligation method (DLM) has been introduced to insert and fix the anvil of the circular stapler for intracorporeal circular esophagojejunostomy in gastric surgery. We adopted this method for intrathoracic anastomosis (IA) in MIE. The aim of this study was to investigate the safety of IA with DLM in MIE.
Methods:
In this study, 48 patients diagnosed with primary middle or lower third segment thoracic esophageal carcinoma with clinical stage I, II, III or IV disease were retrospectively evaluated. Postoperative outcomes were assessed.
Results:
Among the 48 patients, 42 patients underwent laparo-thoracoscopic esophagectomy and IA using a circular stapler with the DLM. The average total operation time and thoracoscopic operation time were 433 and 229 minutes, respectively. The average pursestring suturing time was 4.7 minutes. The rates of anastomotic leakage and stenosis were 2.4% and 14.3%, respectively. The overall incidence of postoperative complications (ClavienDindo grade of ≥III) was 16.7%. The average postoperative stay was 16 days.
Conclusion
The procedure of IA using a circular stapler with the DLM in MIE was safe and provided a low rate of anastomotic leakage.
2.A Novel Technique of Hand-Sewn Purse-String Suturing by Double Ligation Method (DLM) for Intracorporeal Circular Esophagojejunostomy
Yuichi TAKAYAMA ; Yuji KANEOKA ; Atsuyuki MAEDA ; Yasuyuki FUKAMI ; Takamasa TAKAHASHI ; Masahito UJI
Journal of Gastric Cancer 2019;19(3):290-300
PURPOSE: The optimal method for intracorporeal esophagojejunostomy remains unclear because a purse-string suture for fixing the anvil into the esophagus is difficult to perform with a laparoscopic approach. Therefore, this study aimed to evaluate our novel technique to fix the anvil into the esophagus. MATERIALS AND METHODS: This retrospective study included 202 patients who were treated at our institution with an intracorporeal circular esophagojejunostomy in a laparoscopy-assisted total gastrectomy with a Roux-en-Y reconstruction (166 cases) or a laparoscopy-assisted proximal gastrectomy with jejunal interposition (36 cases). After incising 3/4 of the esophageal wall, a hand-sewn purse-string suture was placed on the esophagus. Next, the anvil head of a circular stapler was introduced into the esophagus. Finally, the circular esophagojejunostomy was performed laparoscopically. The clinical characteristics and surgical outcomes were evaluated and compared with those of other methods. RESULTS: The average operation time was 200.3 minutes. The average hand-sewn purse-string suturing time was 6.4 minutes. The overall incidence of postoperative complications (Clavien–Dindo classification grade ≥II) was 26%. The number of patients with an anastomotic leakage and stenosis at the esophagojejunostomy site were 4 (2.0%) and 12 (6.0%), respectively. All patients with stenosis were successfully treated by endoscopic balloon dilatation. There was no mortality. Regarding the materials and devices for anvil fixation, only 1 absorbable thread was needed. CONCLUSIONS: Our procedure for hand-sewn purse-string suturing with the double ligation method is simple and safe.
Anastomotic Leak
;
Classification
;
Constriction, Pathologic
;
Dilatation
;
Esophagus
;
Gastrectomy
;
Head
;
Humans
;
Incidence
;
Laparoscopy
;
Ligation
;
Methods
;
Mortality
;
Postoperative Complications
;
Retrospective Studies
;
Sutures