1.HPLC Determination of Cinobufagin and Resibufogenin in Jiuxin Tablet
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(05):-
Objective To estalish an accurate method for the determination of cinobufagin and resibufogenin in Jiuxin Tablet. Method Waters Symmetry Shield RP18 (3.9 mm?250 mm, 5 ?m) column in an oven at 30 ℃ was need, with a mobile phase consisting of acetonitrile-0.5mol/L kalium dihydrogen phospate (phosphoric acid preparating pH=3.2) (42∶58) and a UV detector at 296 nm, the flow rate was 1.0 mL/min. Results The linear ranges of Cinobufagin was 0.0696~0.8352 ?g. The RSD of measurement precision test was 0.53%, the average recovery was 101.86% (RSD=1.81%, n=5), the linear ranges of Resibufogenin was 0.1576~0.9456 ?g, the RSD of measurement precision test was 0.15%, the average recovery was 102.07% (RSD=1.62%, n =5). Conclusion The method was simple and accurate, and can be used for the quality control of Jiuxin tablet.
2.Study on Quality Standard of Shushenling Capsules
Taishan CAO ; Jiepeng LUO ; Jinbao LIU
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(03):-
Objective To established a method for the quality standard of Shushenling Capsules. Methods Folium Perillae and Rhizoma Chuanxiong in Shushenling Capsules were identified by TLC. The content of emodin was determined by HPLC. Results The spots of samples on TLC can be well separated and the method had strong specificity. The averge recovery of emodin was 99.31% and RSD was 1.54%. Conclusion The method is simpie, sensitive and accurate. It can be used for quality control of Shushenling Capsules.
3.Retrospective analysis of 202 pathological autopsy cases in medical dispute.
Yihu FANG ; Keli ZHANG ; Haisheng YU ; Xuan LI ; Taiping ZHENG ; Taishan HONG ; Liu CAO
Journal of Zhejiang University. Medical sciences 2013;42(4):456-460
OBJECTIVETo analyze the characteristics of autopsies in medical dispute.
METHODSThe data of 202 autopsy cases in medical disputes performed by the Department of Pathology of Jiangxi Medical College from January 2001 to December 2010 were retrospectively analyzed.
RESULTSThe number of autopsy in medical disputes increased year by year. Neonatal, infant and 30 ≊ 60y were more common age groups in dispute; the gender ratio of male to female was 2:1 and more cases were from hospitals in rural areas. Most medical disputes came from in departments of pediatric, obstetrics and gynecology and general surgery. Death caused by cardiovascular diseases ranked at the first place.
CONCLUSIONAutopsy is important in medical disputes to define the cause of death and to preserve evidence.
Adolescent ; Adult ; Aged ; Autopsy ; statistics & numerical data ; Cardiovascular Diseases ; mortality ; Cause of Death ; Child ; Child, Preschool ; Dissent and Disputes ; Female ; Hospital Departments ; statistics & numerical data ; Humans ; Infant ; Infant, Newborn ; Male ; Malpractice ; Middle Aged ; Retrospective Studies ; Sex Ratio ; Young Adult
4.Development of a portable dynamic state ECG based on DSP.
Li SONG ; Qing-jian MENG ; Guang-yu ZHANG ; Wei-fang CAO
Chinese Journal of Medical Instrumentation 2009;33(6):395-397
The Portable dynamic state electrocardiogram collecting system is introduced by using TMS302VC5402, TLC320AD50C, liquid crystal display model, and so on. This dissertation describes the work principle of the system and uses the united algorithm based on wavelet to identify and locate the ECG characteristic waves. This system has as follows of advantages: big memory, low noise,high common mode rejection ratio, the low power consume,the long record time etc.
Algorithms
;
Electrocardiography, Ambulatory
;
instrumentation
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Wavelet Analysis
5.Design and implementation of a VB-based virtual operation system for the console in an x-ray machine.
Hui-qin LIU ; Kai DONG ; Bin YANG ; Yun-xi CAO
Chinese Journal of Medical Instrumentation 2008;32(5):345-362
A new experimental software of an X-ray machine's console virtual operation system based on VB is introduced. This software can simulate the manual operation on the X-ray machine's console, and has the characteristics of easy operation, multi-function and good interactivity.
Computer Simulation
;
Software Design
;
Tomography, X-Ray Computed
;
instrumentation
;
methods
;
User-Computer Interface
6.Short time ECG signal analysis based on the reconstruction of phase space.
Qing JIAO ; Yong-Xin GUO ; Dong CUI ; Wei-Fang CAO ; Ji-Min CAO ; Zheng-Guo ZHANG
Chinese Journal of Medical Instrumentation 2008;32(4):257-264
Based on the reconstruction of two-dimension phase space of time series of short ECG signals, the variation of the strange attractor geometry is described and two indices, VMI and VAI, are derived in this paper. The two indices can distinguish clearly the ECG signals of sinus rhythm, tachycardia and ventricular fibrillation. Stable results of VMI and VAI can be obtained by analyzing ECG signals of several seconds. They are expected to be used in the development of medical instruments for a fast realtime display of analysis results.
Animals
;
Electrocardiography
;
methods
;
Myocardial Infarction
;
physiopathology
;
Rabbits
;
Signal Processing, Computer-Assisted
7.Determination of CD34(+) cells in mobilized peripheral blood by flow cytometry.
Wen-Gang SONG ; Ming-Hui ZHANG ; Wei-Ping ZHANG ; Xun QU ; Xian-Min SONG ; Jian-Min WANG ; Xue-Tao CAO
Journal of Experimental Hematology 2002;10(4):347-350
To explore a simple and effective method to determinate the volume of CD34(+) cells in the peripheral blood of donors received drug mobilization for stem cell transplantation by using flow cytometry, the mobilized peripheral blood from donors and 100 micro l fresh whole blood were labeled with monoclonal antibodies Anti-CD34-PE and Anti-CD45-FITC, after lying the red blood cells, and assessed with flow cytometer FL2 (log) vs SSC (log) and FL1 (log) vs SSC (log) were mainly used for analysis windows. The results showed that a level of CD34(+) cells in whole nucleated cells as low as 0.05% - 0.1% can be detected effectively using this method when 10(5) nucleated cells were counted. At day 5 or day 6, the level of CD34(+) cells in most samples of patients reached a peak volume, some of samples and the levels were more than one percent in. It was concluded that CD34(+) cells can be effectively determined by using this method. According to the relative rate of CD34(+) cells, the time to harvest the stem cells in blood can be determined.
Antigens, CD34
;
blood
;
Blood Donors
;
Flow Cytometry
;
methods
;
Hematopoietic Stem Cells
;
cytology
;
Humans
8.Development of an ECG signals analysis service system based on B/S.
Qing JIAO ; Yong-Xin GUO ; Dong CUI ; Lin-Lin CHE ; Ji-Min CAO ; Zheng-Guo ZHANG
Chinese Journal of Medical Instrumentation 2008;32(3):203-206
An online ECG signals analysis service system based on the network has been established and is introduced in this paper which integrates the advantages of the network, database and ECG analysis tools, providing on-line ECG signal analysis service. Users with the knowledge of general operation of a browser, can process the ECG data and get a real-time display of analysis results.
Computer Systems
;
Database Management Systems
;
Databases, Factual
;
Electrocardiography
;
methods
;
Signal Processing, Computer-Assisted
;
Software Design
9.Determination of tetrandrine and fangchinoline in Radix Stephaniae tetrandrae and its preparation by nonaqueous capillary chromatography.
Yu-Qin LI ; Xing-Guo CHEN ; Yong-Xiu QI ; Ke LI ; Bao-Xiu JIA ; Cai-Hong LIU ; Ming-Liang CAO
China Journal of Chinese Materia Medica 2007;32(19):1992-1995
OBJECTIVETo establish a new method for the determination of fangchinoline and tetrandrine in Stephania tetrandra and Fengtongan capsule by noanqueous capillary electrophoresis.
METHODSeparation was carried out in an uncoated fused capillary (50 cm x 75 microm i.d.) with a running buffer containing 50 mmol x L(-1) ammonium acetate, 1.0% acetic acid and 20% acetonitrile in methanol. A separation voltage of 20 kV and a UV detector wavelength at 214 nm were adopted. Sample was introduced from the anode.
RESULTThe calibration ranges were 1.00, 500 mg x L(-1) for both analytes. Under the optimum conditions, the relative standard deviation (RSD, n = 6) for the migration time of each analyte were 0.09%, 1.9% (intra-day) and 0.63%, 1.9% (inter-day); The RSD for the peak area of each analyte were 0.45%, 5.9% (intra-day) and 2.3%, 5.6% (inter-day), respectively. The contents of the analytes were determined easily with average recoveries 102% for fangchinoline and 105% for tetrandrine in S. tetrandra and 94.6% for fangchinoline and 98.7% for tetrandrine in Fengtongan capsules, respectively.
CONCLUSIONThe proposed method is simple, rapid, accurate and higher repeatable, and can be used to control of the quality of S. tetrandra and Fengtongan capsules.
Benzylisoquinolines ; analysis ; Calibration ; Capillary Electrochromatography ; methods ; Capsules ; Drugs, Chinese Herbal ; chemistry ; isolation & purification ; standards ; Plant Roots ; chemistry ; Plants, Medicinal ; chemistry ; Quality Control ; Reproducibility of Results ; Stephania tetrandra ; chemistry