1.Treatment results of nasopharyngeal carcinoma : a retrospective analysis of 1837 cases in a single institute
Yunsheng GAO ; Chaosu HU ; Hongmei YING ; Guopei ZHU ; Lin KONG ; Xiayun HE ; Tingting XU ; Xiaoshen WANG ; Jing YUAN ; Suqin WU ; Youwang ZHANG ; Taifu LIU
Chinese Journal of Radiation Oncology 2008;17(5):335-339
Objective To summarize our experience and treatment results of nasopharyngeal carcinoma treated in a single institution. Methods From Jan. 2000 to Dec.2003,1837 patients with histologically proven nasopharyngeal carcinoma(NPC) were retrospectively analyzed. The disease was staged according to the Fuzhou stage classification. 885 patients received cisplatin (DDP) based chemotherapy. All patients received radiotherapy to the nasopharynx and neck. The dose was 30.6-74.0 Gy, 1.8-2.0 Gy per fraction over 3.5-8.0 weeks to the primary site with 60Co γ rays or 6 MV X-rays. The dose to lymph nodes was 60-68 Gy. The residual disease was boosted by 192Ir afterloading brachytherapy,small external beam fields, conformal radiotherapy,or X-knife. Results The median follow-up time was 54(3-90) months. The 5-year overall survival(OS), disease-free survival (DFS), relapse-free survival (RFS) and distant metastasis free survival(DMSF) rates were 67.42% ,63.25% ,86.47% and 80.31% ,respectively. Clinical stage was the most significant prognostic factor,and OS was 88% ,74.8% ,65.9% ,52.4% and 20% for stage Ⅰ ,stage Ⅱ,stage Ⅲ,stage ⅣA and stage ⅣB,respectively. Gender,T,N and TNM stage were the significant prognostic factors of OS in multivariate analysis. Conclusions For NPC patients,the 5-year OS of 67.4% is achieved by conventional radiotherapy technique in our institution. Both univariate and multivariate analysis shows that gender and clinical stage are the significant prognostic factors of OS.
2.Research progresses of 3D image fusion technology for guiding endovascular treatments of aortic lesions
Chinese Journal of Interventional Imaging and Therapy 2024;21(1):56-59
3D image fusion technology can fuse image data before and during interventional treatments with mediator of cone-beam CT and guide interventional operations,which might significantly improve the success rate of interventional treatment of aortic lesions and reduce radiation exposure,iodine contrast agent dosage and operation time,etc.The research progresses of 3D image fusion technology for guiding endovascular treatment of aortic lesions were reviewed in this article.
3.Endovascular repair of ruptured abdominal aortic aneurysms assisted by double balloon occlusion technique combined with intra-aneurysm fibrin binder injection technique
Lichun WEI ; Yiming SU ; Taifu XU ; Zhiyong ZHENG ; Ke ZHANG ; Changzhi LUO ; Yi ZHENG ; Xiaomin WEI ; Yihui YE ; Yujian LAN ; Youfu WANG ; Peiyong HOU
Chinese Journal of Surgery 2021;59(12):987-993
Objective:To investigate the long-term efficacy and safety of alternating double balloon occlusion combined with intra-aneurysm injection of human fibrin binder in the endovascular repair of ruptured abdominal aortic aneurysm (rAAA).Methods:The clinical data of 28 patients with rAAA admitted to Department of Vascular Surgery, the Fourth Affiliated Hospital of Guangxi Medical University from January 2015 to December 2019 were retrospectively analyzed. There were 23 males and 5 females, aged (62±5) years (range: 46 to 88 years).The maximum diameter of the tumors was (65.2±10.5) mm (range: 47.3 to 100.5 mm), all of which were subrenal rAAA. The intraoperative EVAR for abdominal aortic aneurysm was successfully performed under the emergency green channel procedure, and this surgery was assisted used the double balloon occlusion technique in aorta of inferior renal and superior renalcombined with intraoperative human fibrin binder injection technique. Observation indexes included: patients with preoperative preparation, operation time, hospitalization days, surgical treatment success rate and the incidence of postoperative complications, and aortic stent form during the follow-up period, the incidence of leakage, branch stents patency rate and infection rates.Results:The preoperative preparation time of 28 patients was (45.5±8.5) minutes (range:20 to 100 minutes). The operation time was (100.0±15.5) minutes (range:85 to 210 minutes), the ICU stay time was (7±2) days(range:1 to 17 days). The length of hospitalization was (13.5±2.5) days(range:5 to 43 days). The success rate of surgical treatment was 92.9% (26/28). Two patients died, 1 case died of postoperative multifocal lacunar cerebral infarction and massive gastrointestinal hemorrhage, and another elderly patient (84 years old) died of massive abdominal fluid due to preoperative abdominal aortic aneurysm rupture, postoperative complicated with significant abdominal compartment syndrome, and secondary multiple organ failure. Balloon occlusion of the upper renal aorta took (13±2)minutes (range:12 to 30 minutes). The intraoperative injection of fibrin adhesive was (14±2) ml(range:6 to 28 ml) in 22 cases. The incidence of major postoperative complications was 57.1% (16/28). Among the 26 patients who survived the surgery, 69.2% (18/26) completed the 3-year follow-up, and the follow-up time was (30±3) months(range:13 to 36 months). During the follow-up, the aortic stent was in good shape without obvious displacement. The incidence of leakage within 6 months after the operation was 10.7% (3/28), and there was no internal leakage in the patients who were followed up for 36 months after the operation. The patency rate of renal artery and iliac artery branch stents was 16/18. The incidence of stent infection was 7.7% (2/26), 1 case occurred at 1 month and another case at 6 months, respectively. All patients recovered after prolonged intensive anti-infection therapy.Conclusions:Under the standard emergency treatment process, the double balloon alternating occlusion technique combined with the intra-aneurysm injection of human fibrin adhesive technique can assist the successful completion of the endovascular repair of rAAA, effectively improve the success rate of treatment for patients, and reduce the incidence of postoperative leakage and serious complications. The mid-term and long-term results of EVAR for rAAA are good, safe and reliable.
4.Endovascular repair of ruptured abdominal aortic aneurysms assisted by double balloon occlusion technique combined with intra-aneurysm fibrin binder injection technique
Lichun WEI ; Yiming SU ; Taifu XU ; Zhiyong ZHENG ; Ke ZHANG ; Changzhi LUO ; Yi ZHENG ; Xiaomin WEI ; Yihui YE ; Yujian LAN ; Youfu WANG ; Peiyong HOU
Chinese Journal of Surgery 2021;59(12):987-993
Objective:To investigate the long-term efficacy and safety of alternating double balloon occlusion combined with intra-aneurysm injection of human fibrin binder in the endovascular repair of ruptured abdominal aortic aneurysm (rAAA).Methods:The clinical data of 28 patients with rAAA admitted to Department of Vascular Surgery, the Fourth Affiliated Hospital of Guangxi Medical University from January 2015 to December 2019 were retrospectively analyzed. There were 23 males and 5 females, aged (62±5) years (range: 46 to 88 years).The maximum diameter of the tumors was (65.2±10.5) mm (range: 47.3 to 100.5 mm), all of which were subrenal rAAA. The intraoperative EVAR for abdominal aortic aneurysm was successfully performed under the emergency green channel procedure, and this surgery was assisted used the double balloon occlusion technique in aorta of inferior renal and superior renalcombined with intraoperative human fibrin binder injection technique. Observation indexes included: patients with preoperative preparation, operation time, hospitalization days, surgical treatment success rate and the incidence of postoperative complications, and aortic stent form during the follow-up period, the incidence of leakage, branch stents patency rate and infection rates.Results:The preoperative preparation time of 28 patients was (45.5±8.5) minutes (range:20 to 100 minutes). The operation time was (100.0±15.5) minutes (range:85 to 210 minutes), the ICU stay time was (7±2) days(range:1 to 17 days). The length of hospitalization was (13.5±2.5) days(range:5 to 43 days). The success rate of surgical treatment was 92.9% (26/28). Two patients died, 1 case died of postoperative multifocal lacunar cerebral infarction and massive gastrointestinal hemorrhage, and another elderly patient (84 years old) died of massive abdominal fluid due to preoperative abdominal aortic aneurysm rupture, postoperative complicated with significant abdominal compartment syndrome, and secondary multiple organ failure. Balloon occlusion of the upper renal aorta took (13±2)minutes (range:12 to 30 minutes). The intraoperative injection of fibrin adhesive was (14±2) ml(range:6 to 28 ml) in 22 cases. The incidence of major postoperative complications was 57.1% (16/28). Among the 26 patients who survived the surgery, 69.2% (18/26) completed the 3-year follow-up, and the follow-up time was (30±3) months(range:13 to 36 months). During the follow-up, the aortic stent was in good shape without obvious displacement. The incidence of leakage within 6 months after the operation was 10.7% (3/28), and there was no internal leakage in the patients who were followed up for 36 months after the operation. The patency rate of renal artery and iliac artery branch stents was 16/18. The incidence of stent infection was 7.7% (2/26), 1 case occurred at 1 month and another case at 6 months, respectively. All patients recovered after prolonged intensive anti-infection therapy.Conclusions:Under the standard emergency treatment process, the double balloon alternating occlusion technique combined with the intra-aneurysm injection of human fibrin adhesive technique can assist the successful completion of the endovascular repair of rAAA, effectively improve the success rate of treatment for patients, and reduce the incidence of postoperative leakage and serious complications. The mid-term and long-term results of EVAR for rAAA are good, safe and reliable.