1.Effect of parecoxib on sufentanil dosage and its analgesic effect in patients with laparoscopic radical resection of rectal carcinoma under combined anesthesia
Yang LIU ; Pingxuan GUO ; Sheng WANG ; Tai WANG ; Qingbo HAN ; Zhenhua WANG
Chinese Journal of Biochemical Pharmaceutics 2015;(6):89-91
Objective To study effect of parecoxib on sufentanil dosage and its analgesic effect in patients with laparoscopic radical resection of rectal carcinoma under combined anesthesia.Methods 120 cases patients diagnosed with rectal cancer and prepared to laparoscopic radical resection of rectal cancer were selected in Kailuan General Hospital, and randomly divided into experimental group and control group, 60 cases in each group, experimental group induced anesthesia with 40mg parecoxib sodium intravenous injection, while the control group were treated with normal saline, the postoperative dosage of sufentanil, analgesia pump using frequency and other indicators were detected at 6,12,24 and 48 h, and analgesic effect were observed.Results Compared with control group, in experimental group, postoperative dosage of sufentanil was less ( P <0.05 ) , analgesia pump pressing times and effective pressing numbers were fewer (P<0.05), VAS pain score was lower (P<0.05) and Ramsay score was lower (P<0.05) at each time point.Conclusion Parecoxib could reduce the dosage of sufentanil after laparoscopic radical resection of rectal cancer, and enhance the analgesic effect.
2.Influence of mesenchymal stem cells implantation on ventricular remodeling and heart function after acute myocardial infarcion
ri-tai, HUANG ; hong-sheng, ZHU ; song, XUE ; feng, LIAN ; gang, HUANG ; jian-jun, LIU ; ru-qi, TAO
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(04):-
Objective To study the influence of mesenchymal stem cells(MSCs) implantation on ventricular remodeling and heart function after myocardial infarcion. Methods Bone marrow was aspirated from Gui-zhou Xiang swines.After being isolated,cultured and co-cultured with 5-azacytidine,either autologous MSCs(experiment group) or a comparable volume of physiologic saline(control group) were injected into the infarcted myocardium.Three and six weeks later,echocardiographic measurement was performed to assess the myocardial structure and heart function,and single photon emission computed tomography(SPECT) was employed for myocardial imaging.Implanted stem cells were detected by the anti-Brdv antibody DAB with HE staining. Results Left ventricular ejection fraction(EF),fractional shortening and wall thickening were higher in experiment group than control group.The thickness of the ventricular wall and septum was found increased while the left ventricular chamber size was smaller in experiment group.It was indicated by SPECT that three and six weeks after implantation,there was obvious image defect in control group while in experiment group there were some imaging areas in the infarcted area.Brdv-labelled cells were observed in the central part of and around the infarcted area.Conclusion Implantation of MSCs into the infarcted myocardium is believed to attenuate the remodeling process,inhibit the extent of wall thinning and dilatation of the ventricular chamber.MSCs implantation may also improve the contractile ability of the myocardium and heart function.
3.Observation on COLIXA3 polymorphism of patients with fluorosis
Li, TANG ; San-xiang, WANG ; Jin-jie, ZHONG ; Yue-xin, ZHANG ; Sheng-bin, BAI ; Ya-lou, ZHANG ; Kai-tai, LIU
Chinese Journal of Endemiology 2012;31(4):369-372
Objective To study the COLIXA3 gene polymorphism of patients with fluorosis and to explore the pathogenesis of COLIXA3 gene in endemic fluorosis.Methods Fifty one cases of patients with drinking-water borne fluorosis were selected as the case group in Xinzhou city,Shanxi province and 28 cases of healthy people were as the control group.Dental fluorosis was detected by Dean method and skeletal fluorosis was examined by X-ray.COLIXA3 of exon 5 gene product of 103 points was amplified by PCR and the gene locus genotype was sequenced.Results Ten cases of mild dental fluorosis,14 cases of moderate dental fluorosis,15 cases of severe dental fluorosis were detected among the 51 patients.The control group was free of dental fluorosis.All the 51 cases of patients with fluorosis had varying degrees of skeletal fluorosis,mainly osteosclerosis lesions,accounting for 86.27%(44/51 ),and mild skeletal fluorosis patients were all osteosclerosis lesions,and osteosclerosis lesions and multiple skeletal lesions were found among moderate and severe skeletal fluorosis patients in the case group,while control group had no skeletal fluorosis.The differences between genotypes of frequency distribution of AA,Aa,aa of COLIXA3 of case and control groups were not statistically significant [96.08%(49/51 ),3.92%(2/51 ),0.00%(0/51) and 96.43%(27/28),3.57%(1/28),0.00%(0/28),x2 =0.94,P > 0.05].ConclusionsCOLIXA3 gene polymorphism is not significantly correlated to fluorosis.
4.Experimental study of cartilage lesions and COLIXA 3 protein expression in rats cartilage with chronic fluorosis
Li, TANG ; Sheng-bin, BAI ; Ya-lou, ZHANG ; Kai-tai, LIU ; Yue-xin, ZHANG ; Jin-jie, ZHONG
Chinese Journal of Endemiology 2011;30(4):389-392
Objective To explore whether different degrees of fluorosis influence the expression of cartilage COLIXA3 protein in fluorosis model rats. Methods Forty male Wistar rats 3 to 4 weeks old were randomly divided into 5 groups according to body mass, and these rats were fed with distilled water containing sodium fluoride(NaF) of 0(control), 25, 50, 100 and 150 mg/L for 6 months, respectively, in order to establish the animal model of drinking water type fluorosis. Pathomorphologieal changes of the osseous tissues of rats were analyzed under light microscope and transmission electron microscope, and the expression of COLIXA3 protein of femur metaphysis was examined by immunohistochemistry. Results HE staining showed different degrees of femoral metaphyseal ossification of cartilage in each experimental group, bone density increased, with sclerotic lesions of skeletal fluorosis. The control group showed no abnormal cartilage. Electron microscopy showed that the experimental groups with varying degrees of cartilage cell swelling, cell matrix fades, 50 mg/L group .showed hyperplasia, and 100,150 mg/L groups were observed with organelles decreased, part of the disintegration of the cartilage cell lacunae, lmmunohistochemical staining of rat chondrocytes COLIXA3 was positive, cytoplasm with brown granules, cartilage COLIXA3 protein expression(23.3 ± 4.5, 41.2 ± 5.6, 26.4 ~ 7.5) in the 25, 50 and 100 mg/L groups enhanced. Compared to the control group (6.1 ± 3.5), the expression of 50 and 100 mg/L groups was significantly increased, and the differences were statistically significant(all P < 0.05). The expression(13.3 ± 4.2)of COLIXA3 protein in 150 mg/L group was decreased compared with the previous three, but is still higher than that of control, and the difference was not statistically significant(P > 0.05). Conclusions There has pathological changes of sclerosing skeletal fluorosis in animal model. Low-dose fluoride promotes while high-dose inhibits cartilage cell proliferation. When fluorine concentration in external environment is too high and with extended exposure to fluoride, direct toxic effects of fluoride on cartilage cells is observed. Fluorine affects and promotes the expression of COLIXA3 protein in cartilage. Low-dose fluoride can promote COLIXA3 protein expression, as the dose increases (over 100 mg/L), the effect decreases.
5.COLIXA3 gene expression of peripheral blood lymphocyte in patients with endemic fluorosis
Li, TANG ; Li-jie, WANG ; Ya-lou, ZHANG ; Sheng-bin, BAI ; Jin-jie, ZHONG ; Yue-xin, ZHANG ; Kai-tai, LIU
Chinese Journal of Endemiology 2012;31(2):144-146
ObjectiveTo study the relationship between expression of a3 chain of collagen Ⅸ (COLIXA3)mRNA in the population exposed to fluorine and fluorosis,in order to reveal the role of COLIXA3 gene in the pathogenesis of endemic fluorosis.MethodsTwelve cases of mild drinking water-born skeletal fluorosis were selected as case groups in Regiment 123 and 128 of Xinjiang Production and Construction Corps Seven Division,6cases of healthy people living in fluorosis areas for more than 10 years as a internal control group and 6 heathly cases living in non-fluorosis areas for more than 10 years as a external control group.The expression of COLIXA3mRNA of peripheral blood lymphocyte of skeletal fluorosis patients and control groups were determined by using SYBR Green Ⅰ chimeric fluorescent method for real-time quantitative PCR.ResultsThe results of the relative expression of COLIXA3 mRNA of case group,internal control group and external control group were 2.16 ± 0.62,1.06 ± 0.09 and 1.05 ± 0.12,respectively.The COLIXA3 expression in case group was significantly higher than that of the internal control group and the external control group (all P < 0.05),while the difference of COLIXA3expression between the internal control group and the external control group was not significantly different (P >0.05).ConclusionsFluorine contributes to the expression of COLIXA3 mRNA in peripheral blood lymphocyte,and the expression is up to 2 times higher than that of the control groups,meaning potential biomarkers.
6.Cardiovascular circulation feedback control treatment instrument.
Yu-zhi GE ; Xing-huan ZHU ; Guo-tai SHENG ; Ping-liang CAO ; Dong-sheng LIU ; Zhi-ting WU
Chinese Journal of Medical Instrumentation 2005;29(4):255-266
The cardiovascular circulation feedback control treatment instrument (CFCTI) is an automatic feedback control treatment system, which has the function of monitoring, alarming, trouble self-diagnosis and testing on the line in the closed loop. The instrument is designed based on the successful clinical experiences and the data are inputted into the computer in real-time through a pressure sensor and A/D card. User interface window is set up for the doctor's choosing different medicine. The orders are outputted to control the dose of medicine through the transfusion system. The response to medicine is updated continually. CFCTI can avoid the man-made errors and the long interval of sampling. Its reliability and accuracy in rescuing the critical patients are much higher than the traditional methods.
Automation
;
instrumentation
;
Cardiovascular System
;
Feedback
;
Medication Systems
7.Effects of Shuxuetongmai Capsule on Expression of p38 MAPK in Rats with Cerebral Ischemia/Reperfusion
Tai LIU ; Deqing HUANG ; Yuankan ZHANG ; Dan LI ; Shuwu HUANG ; Lulu TAN ; Yonghui LIU ; Sheng LI ; Ping YAO ; Xi SONG ; Qianchao HE
Herald of Medicine 2015;(7):851-855
Objective To explore the neuroprotection of Shuxuetongmai capsule pretreatment, and the effect on the expression of p38 mitogen-activated protein kinase (p38MAPK) in rats with middle cerebral artery occlusion. Methods Ninety-six male SD rats were divided randomly into sham-operated group,ischemia/reperfusion group (I/R),ischemia preconditioning group (IP),and Shuxuetongmai group(n=24). Each group was further randomly divided into 4 subgroups by 3 h, 6 h, 24 h and 72 h after reperfusion, 6 rats in each subgroup. Sham-operated group was only performed artery separation . The middle cerebral artery occlusion (MCAO) model was set up in I/R rats by Longa method. The IP rats were performed for three minutes on the bilateral carotid artery ligation, and formed MCAO model 24 hours later. The rats in the Shuxuetongmai group were pretreated with Shuxuetongmai capsules for 14 days on gavage before the establishment of MCAO model. The neurological deficits were graded in rats by Zea Longa method. Western Blot was used to determine the protein expression of p38MAPK and P-p38MAPK. Tunel method was applied to detect the apoptosis of neurons and the relationship between expression of p38MAPK, P-p38MAPK and apoptosis of neuron. Results No neurological dysfunction appeared in the sham-operated group at each time points, but not for the other groups, which reached the peak at 24 h. Compared with the I/R group, IP group and Shuxuetongmai group presented the mild neurologic function deficiency at different time points in rats (P<0. 05), and no significant differences occurred between ischemia preconditioning group and Shuxuetongmai group (P>0.05). The obvious variation of the value of P-p38MAPK/p38MAPK wasn't detected in sham-operated group at different time points, while obviously presented in I/R group, and the ratios of P-p38MAPK/p38MAPK were increased gradually followed with reperfusion, approaching to the highest level at 24 h. Compared with the I/R group, the P-p38MAPK/p38MAPK declined from 3 h and to the lowest level at 24 h of reperfusion, in both IP and Shuxuetongmai groups(P<0. 05), and with similar phosphorylation. At different time points,very few neurons apoptosis were detected in sham-operated groups, but which increased gradually after reperfusion in other groups, and reached to the peak at 24 h. The neurons apoptosis in both IP group and Shuxuetongmai group were less than that in IR group ( P<0. 05 ) at different time points, and it showed no significant differences on neurons apoptosis between ischemia/preconditioning group and Shuxuetongmai group in rats (P>0. 05). Conclusion Shuxuetongmai capsule pretreatment can induce brain ischemic tolerance, attenuate the apoptosis of neurons in cerebral ischemia reperfusion, and improve neurologic function. The mechanism may be related to the inhibition of p38MAPK phosphorylation.
8.The patient-reported outcome of age-related cataract using Catquest-8SF questionnaire
International Eye Science 2019;19(2):179-187
AIM: To assess the patient-reported outcome of phacoemulsification with posterior chamber single focus foldable intraocular lens(SIOL)using the Chinese version of Catquest-8SF questionnaire. We would mainly evaluate the applicability of Catquest-8SF scale in northern Chinese and evaluate its sensitivity to cataract surgery.
METHODS:Prospective clinical case follow-up study. The patients were recruited from The Central Hospital of Tai'an and completed the Catquest-8SF questionnaire by face-to-face interviews before and 3mo after surgery at the hospital.
RESULTS: A total of 120 cataract patients completed the Catquest-8SF at baseline. The preoperative score of the Catquest-8SF-CN had a significant negative correlation with preoperative binocular mean weighted logMAR visual acuity and age(P<0.05), while a significant positive correlation with education level(P<0.001). The patients without systemic comorbidities got higher score than those who with(P<0.05). Three months after surgery, 102(85%)patients came for follow-up and completed the questionnaire. Significant improvement of visual acuity was observed in both binocular and monocular surgery groups(t=10.404, P<0.001). There was higher improvement in binocular weighted logMAR visual acuity of binocular surgery group than in monocular surgery group(P<0.001). The postoperative score were significantly higher in both groups than before(P<0.001). There was a significant improvement in the total score after cataract surgery. Ninety-four patients(92.2%)were very satisfied or satisfied with the operation. The degree of satisfaction was significantly correlated with the improvement score of the scale and it was also correlated with their expectation of the surgery.
CONCLUSION: The Chinese version of Catquest-8SF questionnaire is suitable for the age-related cataract population in northern China. It is highly responsive to cataract surgery and brief, so it may have the potential to become part of a routine clinical assessment for cataract surgery in China.
9.EGFR mutation predicts response and prognosis in iressa-treated advanced-stage non-small cell lung cancer.
Yu HAN ; Jian-ming XU ; Hai-qing DUAN ; San-tai SONG ; Xiao-qing LIU ; Yang ZHANG ; Jing-sheng ZHANG
Chinese Journal of Oncology 2007;29(4):278-283
OBJECTIVETo investigate the correlation between mutation in EGFR tyrosine kinase domain and tumor response as well as prognosis in advanced stage non-small cell lung cancer (NSCLC) treated with iressa.
METHODSFrom May 2002 to Feb. 2005, iressa was orally administered at a dose of 250 mg once daily for 106 advanced stage NSCLC patients until occurrence of disease progression or intolerable toxicity. Cancer tissue was obtained from these patients, and DNA was extracted for analysis of mutation in exon 18 to 24 of EGFR. Exon 18 to 24 of EGFR were amplified by nest PCR, sequenced and analyzed from both sense and antisence directions.
RESULTSPrimary NSCLC tissue specimens consisted of 25 frozen tissue blocks and 81 paraffin-embedded tumor tissue blocks from 106 consecutive NSCLC patients. Mutation was found to be more frequent in the adenocarcinoma than in the squamous cell carcinoma (35.9% vs 14.3%, P =0.033). Mutation was identified in 32 patients (30.2%). Response rate to iressa was 71.9% in the patients with EGFR mutation versus 13.5% in those without mutation (P <0.01). Compared with the patients without EGFR mutation, those with mutation had longer overall survival (median, 13.45 vs. 5.25 months; P<0.01) and median time to progression (median, 8.35 vs. 3.0 months; P <0.01).
CONCLUSIONEGFR mutation may be positively correlated with the response and survival in advanced stage Chinese NSCLC patient treated with iressa.
Adenocarcinoma ; drug therapy ; genetics ; pathology ; Adolescent ; Adult ; Aged ; Antineoplastic Agents ; therapeutic use ; Carcinoma, Non-Small-Cell Lung ; drug therapy ; genetics ; pathology ; Carcinoma, Squamous Cell ; drug therapy ; genetics ; pathology ; Exons ; Female ; Follow-Up Studies ; Humans ; Kaplan-Meier Estimate ; Lung Neoplasms ; drug therapy ; genetics ; pathology ; Male ; Middle Aged ; Neoplasm Staging ; Point Mutation ; Prognosis ; Quinazolines ; therapeutic use ; Receptor, Epidermal Growth Factor ; genetics ; Sequence Deletion
10.Assessment of occupational health risk of noise in a plastic products enterprise
ZHAN Li chun XIAO Bin YANG Ai chu GUO Jian yu LONG Tai hua XU Guo yong YAN Mao sheng LIU Mao ling
China Occupational Medicine 2022;49(05):553-
Objective
To assess the occupational health risk of noise in a plastic products enterprise and determine the key risk
Methods -
points. The workplace of a plastic products enterprise and its 388 noise exposed workers were selected as the
,
research subjects using a convenient sampling method. The noise intensity in the workplace of the enterprise was measured and
- GBZ/T 229.4-2012
the individual noise exposure level and pure tone hearing test were carried out in the noise exposed workers.
Classification of Occupational Hazards at Workplaces--Part 4: Occupational Exposure to Noise( GBZ/T
hereinafter referred to as
229.4-2012) -
was used to evaluate the hazardous degree of noise in different posts. The risk of high frequency hearing loss
( ) - ( ) - , ,
HFHL and occupational noise induced deafness ONID in noise exposed workers in different posts at 45.0 50.0 55.0 and
WS/T 754-2016 Guideline for Risk Management of Occupational Noise Hazard(
60.0 years of age were predicted using hereinafter
WS/T 754-2016)Results
referred to as . The noise in the workplace of this plastic product enterprise was found to exceed the
-
occupational exposure limits with the rate of 46.6%. The maximum level of normalization of equivalent continuous A weighted
- ( )
sound pressure level to a nominal 40 h working week of exposure to noise in workers of six posts was 84.0 93.0 dB A .
- , , ,
According to GBZ/T 229.4 2012 the noise hazards of the posts including extrusion premixing unloading and utility
- ,
maintenance were mild or moderate except for the film and packaging posts. According to WS/T 754 2016 the risks of HFHL in
, ,
the film and packaging operators at age ≥50.0 years old were at acceptable risk and the risks of HFHL in operators of extrusion
, ,
premixing unloading and utility maintenance at age ≥45.0 years old were at moderate risk or high risk. The risks of ONID for
,
the film packaging and utility maintenance operators at age ≥55.0 years old were at acceptable risk or moderate risk. The risksof ONID for extrusion premixing and unloading operators at age ≥50.0 years old were at high risk. Extrusion operators with
( )
exposure to toluene below the occupational exposure limit had a higher risk of HFHL high risk than unloading operators
( ) Conclusion
moderate risk at age 45.0 years with the same noise intensity. The noise exposure intensity is high in the
,
workplace of the plastic product enterprise. The workers in posts of extrusion premixing and unloading are at high risk levels of
HFHL and ONID.