1.Digital Biomarkers in Living Labs for Vulnerable and Susceptible Individuals: An Integrative Literature Review
YouHyun PARK ; Tae-Hwa GO ; Se Hwa HONG ; Sung Hwa KIM ; Jae Hun HAN ; Yeongsil KANG ; Dae Ryong KANG
Yonsei Medical Journal 2022;63(S1):43-55
Purpose:
The study aimed to identify which digital biomarkers are collected and which specific devices are used according to vulnerable and susceptible individual characteristics in a living-lab setting.
Materials and Methods:
A literature search, screening, and appraisal process was implemented using the Web of Science, Pubmed, and Embase databases. The search query included a combination of terms related to “digital biomarkers,” “devices that collect digital biomarkers,” and “vulnerable and susceptible groups.” After the screening and appraisal process, a total of 37 relevant articles were obtained.
Results:
In elderly people, the main digital biomarkers measured were values related to physical activity. Most of the studies used sensors. The articles targeting children aimed to predict diseases, and most of them used devices that are simple and can induce some interest, such as wearable device-based smart toys. In those who were disabled, digital biomarkers that measured location-based movement for the purpose of diagnosing disabilities were widely used, and most were measured by easy-to-use devices that did not require detailed explanations. In the disadvantaged, digital biomarkers related to health promotion were measured, and various wearable devices, such as smart bands and headbands were used depending on the purpose and target.
Conclusion
As the digital biomarkers and devices that collect them vary depending on the characteristics of study subjects, researchers should pay attention not only to the purpose of the study but also the characteristics of study subjects when collecting and analyzing digital biomarkers from living labs.
2.Immunoglobulin G4-Related Kidney Disease with Membranous Proliferative Glomerulonephritis Presenting with a Renal Pelvic Mass
Jong Tae CHO ; Eun-Kyoung LEE ; Jai Hyang GO ; Yong-Moon LEE ; Hwa Young LEE ; So Mi KIM
Korean Journal of Medicine 2021;96(1):48-52
Immunoglobulin G4 (IgG4)-related kidney disease is a chronic immune-mediated fibro-inflammatory disorder characterized by multiple organ infiltration with IgG4-positive plasma cells, storiform fibrosis, and obliterative phlebitis or tumefactive lesions. Previous studies have explored IgG4-related kidney disease, increasing our understanding of its clinical manifestations, and pathological and radiologic findings. However, IgG4-related kidney disease can be misdiagnosed since it mimics malignancies. We report a case of a 77-year-old Korean man diagnosed with IgG4-related kidney disease with membranous proliferative glomerulonephritis, presenting with a renal pelvic mass suspected of being malignant.
3.Immunoglobulin G4-Related Kidney Disease with Membranous Proliferative Glomerulonephritis Presenting with a Renal Pelvic Mass
Jong Tae CHO ; Eun-Kyoung LEE ; Jai Hyang GO ; Yong-Moon LEE ; Hwa Young LEE ; So Mi KIM
Korean Journal of Medicine 2021;96(1):48-52
Immunoglobulin G4 (IgG4)-related kidney disease is a chronic immune-mediated fibro-inflammatory disorder characterized by multiple organ infiltration with IgG4-positive plasma cells, storiform fibrosis, and obliterative phlebitis or tumefactive lesions. Previous studies have explored IgG4-related kidney disease, increasing our understanding of its clinical manifestations, and pathological and radiologic findings. However, IgG4-related kidney disease can be misdiagnosed since it mimics malignancies. We report a case of a 77-year-old Korean man diagnosed with IgG4-related kidney disease with membranous proliferative glomerulonephritis, presenting with a renal pelvic mass suspected of being malignant.
4.Characteristics and survival of patients with atypical chronic myeloid leukemia
Jee Hyun KONG ; Hohyung NAM ; Tae Hwa GO ; Shin Young HYUN ; Kwang Yong SHIM
Blood Research 2019;54(3):233-236
No abstract available.
Humans
;
Leukemia, Myeloid, Chronic, Atypical, BCR-ABL Negative
5.Survival impact of adherence to tyrosine kinase inhibitor in chronic myeloid leukemia
Yundeok KIM ; Tae-Hwa GO ; Jaeyeon JANG ; Jii Bum LEE ; Seung Taek LIM ; Kwang Yong SHIM ; Jong In LEE ; Jee Hyun KONG
The Korean Journal of Internal Medicine 2021;36(6):1450-1458
Background/Aims:
Adherence to tyrosine kinase inhibitors (TKIs) has become a critical aspect of care in chronic myeloid leukemia (CML). We aimed to examine the association of TKI adherence with overall survival (OS) outcomes in Korean patients diagnosed with CML and treated with TKIs using data from the National Health Information Database.
Methods:
This study included 2,870 CML patients diagnosed between 2005 and 2013. Drug adherence was evaluated according to the medication possession ratio (MPR) and classified as high adherence (i.e., MPR ≥ 0.95 [upper 50%]), moderate adherence (i.e., MPR ≥ 0.68 and < 0.95 [middle 25%]), and low adherence (i.e., MPR < 0.68 [lower 25%]).
Results:
The median MPR was 0.95 (range, 0 to 4.67). Male sex (p = 0.003), age < 70 years (p < 0.001), high income (≥ 30%, p < 0.001), and maintaining frontline TKI (< 0.001) were associated with better adherence. Adherence to dasatinib was the lowest (vs. imatinib or nilotinib, p < 0.001). Compared with high MPR patients, those with moderate MPR (hazard ratio [HR], 4.90; 95% confidence interval [CI], 3.87 to 6.19; p < 0.001) and low MPR (HR, 11.6; 95% CI, 9.35 to 14.42; p < 0.001) had poorer OS.
Conclusions
Adherence to TKI treatment is an important factor predicting survival outcomes in Korean CML patients. Male sex, age < 70 years, high income, and maintaining frontline TKI are associated with high adherence to TKI. Thus, those without these characteristics should be closely monitored for treatment adherence.
6.A Novel One-Step Knife Approach Can Reduce the Submucosal Injection Time of Endoscopic Submucosal Dissection: A SingleBlinded Randomized Multicenter Clinical Trials
Hyunil KIM ; Jin Woo KIM ; Hong Jun PARK ; Su Young KIM ; Hyun-Soo KIM ; Gwang Ho BAIK ; Sung Chul PARK ; Sang Jin LEE ; Tae-Hwa GO
Gut and Liver 2022;16(1):44-52
Background/Aims:
Endoscopic submucosal dissection (ESD) is a curative treatment modality for early gastric neoplasms; however, ESD can be a time-consuming process. To overcome this pitfall, we developed the one-step knife (OSK) approach, which combines an endoscopic knife and injection needle on a single sheath. We aimed to evaluate whether this approach could reduce the ESD procedure time.
Methods:
This single-blinded randomized multicenter trial at four tertiary hospitals from June 2019 to June 2020 included patients aged 19 to 85 years undergoing ESD. Patients were randomly assigned to two groups (OSK or conventional knife [CK]). The injection time, total procedure time, resected specimen size, submucosal fluid amount, degree of device satisfaction, and adverse events were evaluated and compared between groups.
Results:
Fifty-one patients were analyzed (OSK: 25 patients and CK: 26 patients). No baseline differences were observed between groups, with the exception of a higher portion of males in the OSK group. The mean injection time was significantly reduced in the OSK group (39.0 seconds) compared to that in the CK group (87.5 seconds, p<0.001). A decrease of more than 10 minutes in the total procedure time (18.0 minutes vs 28.1 minutes, p=0.055) in the OSK group compared to the CK group was observed. Second-look esophagogastroduodenoscopy revealed two delayed bleeding cases in the OSK group that were easily controlled by endoscopic hemostasis.
Conclusions
OSK reduced the injection time and showed a decrease in total procedure time compared with the CK approach. OSK can be a feasible tool for ESD, especially in difficult cases.
7.Two Cases of Hypophosphatemic Osteomalacia After Long-term Low Dose Adefovir Therapy in Chronic Hepatitis B and Literature Review.
Hye Jin JEONG ; Ji Min LEE ; Tae Han LEE ; Ji Yeon LEE ; Han Byeol KIM ; Mi Hwa HEO ; Go CHOI ; Jin Nyeong CHAE ; Ji Min KIM ; Sang Hyon KIM ; Kun Young KWON
Journal of Bone Metabolism 2014;21(1):76-83
Adefovir dipivoxil (ADV) is a nucleotide used as long-term therapy of chronic hepatitis B. Many published reports have shown that long-term high-dose therapy with adefovir can be associated with proximal renal tubular dysfunction resulting in significant hypophosphatemia, renal insufficiency and osteomalacia. We have encountered two patients who developed evidence of hypophosphatemic osteomalacia while on long-term low-dose adefovir therapy for chronic hepatitis B. We report on its clinical features and its potential resolution with cessation of the drug and supplementation with phosphate. We also reviewed the other published cases associated with hypophosphatemic osteomalacia after low-dose adefovir therapy. The symptoms and the hypophosphatemia improved after cessation of the drug and supplementation with phosphate in most cases. Patients taking adefovir long-term should receive regular investigation of the phosphate level and renal function.
Fanconi Syndrome
;
Hepatitis B, Chronic*
;
Hepatitis, Chronic*
;
Humans
;
Hypophosphatemia
;
Kidney Diseases
;
Osteomalacia*
;
Renal Insufficiency
8.Reference diameter and characteristics of the distal radial artery based on ultrasonographic assessment
Jun-Won LEE ; Jung-Woo SON ; Tae-Hwa GO ; Dae Ryong KANG ; Sang Jun LEE ; Se Eun KIM ; Dong-Hyuk CHO ; Young Jun PARK ; Young Jin YOUN ; Min-Soo AHN ; Sung Gyun AHN ; Jang-Young KIM ; Byung-Su YOO ; Junghan YOON ; Seung-Hwan LEE
The Korean Journal of Internal Medicine 2022;37(1):109-118
Background/Aims:
While distal radial artery (DRA) access is increasingly being used for diagnostic coronary angiography, limited information is available regarding DRA size. We aimed to determine the DRA reference diameters of Korean patients and identify the predictors of DRA diameter < 2.3 mm.
Methods:
The outer bilateral DRA diameters were assessed using a linear ultrasound probe in 1,162 consecutive patients who underwent transthoracic echocardiography. The DRA diameter was measured by the perpendicular angle in the dorsum of the hand, and the average values were compared by sex. DRA diameter < 2.3 mm was defined as unsuitable for routine diagnostic coronary angiography using a 5 Fr introducer sheath.
Results:
The mean DRA diameters were 2.31 ± 0.43 mm (right) and 2.35 ± 0.45 mm (left). The DRA was smaller in women than men (right: 2.15 ± 0.38 mm vs. 2.43 ± 0.44 mm, p < 0.001; left: 2.18 ± 0.39 mm vs. 2.47 ± 0.45 mm, p < 0.001). The DRA diameter was approximately 20% smaller than the radial artery diameter. A total of 630 (54.2%) and 574 (49.4%) patients had DRA diameter < 2.3 mm in the right and left hands, respectively. Female sex, low body mass index (BMI), and low body surface area (BSA) were significant predictors of DRA diameter < 2.3 mm.
Conclusions
We provided reference DRA diameters for Korean patients. Approximately 50% of the studied patients had DRA diameter < 2.3 mm. Female sex, low BMI, and low BSA remained significant predictors of DRA diameter < 2.3 mm.
9.Evaluation of Adherence to Guideline for Heart Failure with Reduced Ejection Fraction in Heart Failure with Preserved Ejection Fraction and with or without Atrial Fibrillation
Min-Soo AHN ; Byung-Su YOO ; Jung-Woo SON ; Young Jun PARK ; Hae-Young LEE ; Eun-Seok JEON ; Seok-Min KANG ; Dong-Ju CHOI ; Kye Hun KIM ; Myeong-Chan CHO ; Seong Yoon KIM ; Dae Ryong KANG ; Tae-Hwa GO
Journal of Korean Medical Science 2021;36(40):e252-
Background:
This study evaluated the relationship between guideline adherence for heart failure (HF) with reduced ejection fraction (HFrEF) at discharge and relevant clinical outcomes in patients with acute HF with preserved ejection fraction (HFpEF) with or without atrial fibrillation (AF).
Methods:
We analyzed Korean Acute Heart Failure Registry data for 707 patients with HFpEF with documented AF and 687 without AF. Guideline adherence was defined as good or poor according to the prescription of angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, β-blockers, and mineralocorticoid receptor antagonists. Anticoagulation adherence was also incorporated for the AF group.
Results:
Among patients with normal sinus rhythm, those with poor guideline adherence had a reduced prevalence of comorbidities and favorable clinical characteristics when compared with those with good guideline adherence. Using inverse probability of treatment weighting (IPTW) to address the bias of nonrandom treatment assignment, good adherence was associated with a poor 60-day composite endpoint in the multivariable Cox model (weighted hazard ratio [wHR], 1.74; 95% confidence interval [CI], 1.01–3.00; P = 0.045). For patients with AF, baseline clinical characteristics were similar according to the degree of adherence. The IPTW-adjusted analysis indicated that good adherence was significantly associated with the 60-day composite endpoint (wHR, 0.47; 95% CI, 0.27–0.79; P = 0.005). In the analysis excluding warfarin, good adherence was associated with 60-day rehospitalization (wHR, 0.60; 95% CI, 0.37–0.98; P = 0.040), 1-year re-hospitalization (wHR, 0.67; 95% CI, 0.48–0.93; P = 0.018), and the composite endpoint (wHR, 0.77; 95% CI, 0.59–0.99; P = 0.041).
Conclusion
Our findings indicate that good adherence to guidelines for HFrEF is associated with a better 60-day composite endpoint in patients with HFpEF with AF.
10.Evaluation of Adherence to Guideline for Heart Failure with Reduced Ejection Fraction in Heart Failure with Preserved Ejection Fraction and with or without Atrial Fibrillation
Min-Soo AHN ; Byung-Su YOO ; Jung-Woo SON ; Young Jun PARK ; Hae-Young LEE ; Eun-Seok JEON ; Seok-Min KANG ; Dong-Ju CHOI ; Kye Hun KIM ; Myeong-Chan CHO ; Seong Yoon KIM ; Dae Ryong KANG ; Tae-Hwa GO
Journal of Korean Medical Science 2021;36(40):e252-
Background:
This study evaluated the relationship between guideline adherence for heart failure (HF) with reduced ejection fraction (HFrEF) at discharge and relevant clinical outcomes in patients with acute HF with preserved ejection fraction (HFpEF) with or without atrial fibrillation (AF).
Methods:
We analyzed Korean Acute Heart Failure Registry data for 707 patients with HFpEF with documented AF and 687 without AF. Guideline adherence was defined as good or poor according to the prescription of angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, β-blockers, and mineralocorticoid receptor antagonists. Anticoagulation adherence was also incorporated for the AF group.
Results:
Among patients with normal sinus rhythm, those with poor guideline adherence had a reduced prevalence of comorbidities and favorable clinical characteristics when compared with those with good guideline adherence. Using inverse probability of treatment weighting (IPTW) to address the bias of nonrandom treatment assignment, good adherence was associated with a poor 60-day composite endpoint in the multivariable Cox model (weighted hazard ratio [wHR], 1.74; 95% confidence interval [CI], 1.01–3.00; P = 0.045). For patients with AF, baseline clinical characteristics were similar according to the degree of adherence. The IPTW-adjusted analysis indicated that good adherence was significantly associated with the 60-day composite endpoint (wHR, 0.47; 95% CI, 0.27–0.79; P = 0.005). In the analysis excluding warfarin, good adherence was associated with 60-day rehospitalization (wHR, 0.60; 95% CI, 0.37–0.98; P = 0.040), 1-year re-hospitalization (wHR, 0.67; 95% CI, 0.48–0.93; P = 0.018), and the composite endpoint (wHR, 0.77; 95% CI, 0.59–0.99; P = 0.041).
Conclusion
Our findings indicate that good adherence to guidelines for HFrEF is associated with a better 60-day composite endpoint in patients with HFpEF with AF.