1.Down Syndrome with Familial Eruptive Syringoma.
Seung Ho CHANG ; Tae Young YOON
Korean Journal of Dermatology 1994;32(3):532-536
Down syndrome is the most, well known autosomal trisomy and e large number of abnormal skin features have been reported to occur in patients with Down syndromir. including syringoma. Syringomas occur with increased frequency in patients with Down syringoma, usually limited to the region around the eyes. but few cases of eruptive syringoma with Down syndrome have been reported. We reported the case of familial eruptive syringoma in a 13 years old patient with Down syndrome.
Adolescent
;
Down Syndrome*
;
Humans
;
Livedo Reticularis
;
Skin
;
Syringoma*
;
Trisomy
2.A Case of Heparin Necrosis.
Tae Young YOON ; Seung Ho CHANG
Annals of Dermatology 1994;6(1):74-77
Skin necrosis is a rare complication of heparin administration that is usually localized to injection sites. We report a case of skin necrosis that was caused by minidose intraarterial infusion of porcine heparin which had been used in a touch to prevent coagulation in percutaneous intraarterial cannula. The skin necrosis appeared 35 days after starting heparin use.
Catheters
;
Heparin*
;
Infusions, Intra-Arterial
;
Necrosis*
;
Skin
3.A case of hydroa vacciniforme with ocular involvment.
Seung Ho CHANG ; Tae Young YOON
Korean Journal of Dermatology 1993;31(4):612-615
Hydroa Vacciniforme is a rare, chronic, photosensitivity disorder witli onset in childhood that is characterized by recurrent, discrete vesiculation, necrosis and vacciniform scarring limited to sun exposed skin. We report a case of hydroa vacciniforme associated with ocular inwlvment in which vesicles could be induced only with single MED exposure to UVA.
Cicatrix
;
Hydroa Vacciniforme*
;
Necrosis
;
Photosensitivity Disorders
;
Skin
;
Solar System
4.Three Casesof Livedo Vasculitis Cleared by Combined Therapy of Acetylsalicylic Acid , Dipyridamole and Nifedipine.
Tae Young YOON ; Seung Ho CHANG
Korean Journal of Dermatology 1994;32(2):294-299
Livedo vasculitis clinically shows purpuric papules and recurrent ulcers in the lower extremities, mainly on the ankles, leaving characteristic scars called atrophie blanche after the healing of the ulcers. Its characteristic histopathologic features and clinical evolution indicate that the common pathologic event is occlusion of vessels in the middle and deep dermis. In Korean literature, seven cases of this disease have been reported but the response of the treatment was not, satisfactory. We report three cases of livedo vasculitis cleared by combined ther by of acetylsalicylic acid, dipyridamole and nifedipine, which has not been reported in Korean literatur.
Ankle
;
Aspirin*
;
Cicatrix
;
Dermis
;
Dipyridamole*
;
Lower Extremity
;
Nifedipine*
;
Ulcer
;
Vasculitis*
5.DIMENSIONAL ACCURACY OF EPOXY RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS.
Su Kyoung CHANG ; Ik Tae CHANG ; Soon Ho YIM
The Journal of Korean Academy of Prosthodontics 1999;37(3):383-394
The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has some problems such as the weakness in its strength and low abrasion resistance. Recently, epoxy resin die systems have become available. The purpose of this study was to examine two commercially available resin die systems and evaluate some characteristics for their clinical performance. This study evaluated the dimensional accuracy of epoxy resins and their wettability with impression materials. In this study, the first experiment was about dimensional accuracy of different die materials. The master model was made of stainless steel. 10 models were made of two epoxy resins (Die-epoxy, Tri-epoxy) and a die stone (Fujirock) each. Occlusal diameter (Dimension I), occluso-gingival height (Dimension II), and interabutment distance (Dimension III) wee measured in each model. Next, the contact angles of die materials with impression materials were observed. The blocks were made of polyether, hydrophilic additional silicone, polysulfide impression materials. By dropping the same amount (0.05ml) of Tri-epoxy, Die-epoxy, and die stone on the blocks, 10 samples of each die material were made. After setting of materials, the contact angles were measured. The results of this study were as follows. 1. The expansion of stone die and the shrinkage of resin dies in occlusal diameter were observed, and stone and Tri-epoxy were expanded and Die-epoxy was shrinked in occluso-gin-gival height. There was little change among materials in interabutment distance (p>0.05). 2. In comparison with the mater model, Tri-epoxy had the least variation in measurement of the three die systems examined. Did-epoxy was next, and die stone showed the greatest variation. 3. The compatibility of die stone for polyether, hydrophilic additional silicone, polysulfide decreased in order, wherease epoxy materials had the decreased compatibility for polyether and polysulfide, hydrophilic additional silicone in order. It was not statistically different between polyether and polysulifide (p>0.05). 4. The contact angles of Tri-epoxy, Die-epoxy, die stone were getting bigger in order.
Epoxy Resins*
;
Silicones
;
Stainless Steel
;
Wettability
6.Photoelastic stress analysis on the supporting tissue of mandibular distal extension removable partial denture with various design of direct retainers.
Chang Ho LEE ; Kwang Nam KIM ; Ik Tae CHANG
The Journal of Korean Academy of Prosthodontics 1992;30(2):203-224
No abstract available.
Denture, Partial, Removable*
7.Differential diagnosis of lateralized cerebral dysfunction through the multiple discriminant function analysis of KWIS and MMPI responses.
Tae Ho YUM ; Jong Ho SONG ; Hwan Il CHANG
Journal of Korean Neuropsychiatric Association 1991;30(1):188-197
No abstract available.
Diagnosis, Differential*
;
MMPI*
8.DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC.
Si Hyuk LEE ; Ik Tae CHANG ; Soon Ho YIM
The Journal of Korean Academy of Prosthodontics 1999;37(2):167-184
The purpose of this study was to evaluate and compare the fit of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data was stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system. SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature for 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co. Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows : 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas. 3. There were no statistical differences among the positive errors of the four types of inject-ion denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PRERform system and SR-Ivocap system, they have the tendency of inaccurate fit lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of inject-ion denture curing methods.
Alveolar Process
;
Denture Bases*
;
Dentures*
;
Microcomputers
;
Water
;
Weights and Measures
9.ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS.
Kee Hong KIM ; Ik Tae CHANG ; Soon Ho YIM
The Journal of Korean Academy of Prosthodontics 1999;37(3):301-312
The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone models were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to polysulfide, exress, and alginate in reproducing full arch mode (p<0.05). 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether, extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate (p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05). 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).
Colloids
;
Elastomers*
;
Polyvinyls
;
Siloxanes
;
Stainless Steel
10.An Immunohistochemical Stain in Paget's Disease.
Hong Tak LEE ; Seung Ho CHANG ; Tae Young YOON
Korean Journal of Dermatology 1998;36(5):796-803
BACKGROUND: Generally, there are few problems in the diagnosis of Paget's disease(PD) using the H&E stain. However, the differentiation of PD from the clonal type of Bowens disease and superficial spreading melanoma in situ that shows pagetoid spreading of tumor cells, may present diagnostic difficulties. In addition, the specia1 stains used for demonstrating the presenee of Pagets cells, such as PAS and mucicarmim, are non-specific and not always sensitive. So, inenunohistochemical stains with monoclonal antibodies against various antigens may be helpful for differentiating PD from ather morphologically similar skin lesions. OBJECTIVE: The purpose of this study was to investigate the diagnostic accuracy of immunohisto- chemical staining for diagnostic use in PD. METHODS: Immunohistochemical stains used in the biotin streptavidin amplificxl technique with monoclonal antibodies to several low rnolecular weight cytokeratin(CK)s, EMA and CEA, were performed on formalin-fixed, paraffin-embedded tissue. Twelve cases of PD(10 cases of extranmmmary PD and 2 cases of mammary PD), five cases of superficial spreading melanoma in situ and five cases of Bowens disease were investigated. RESULTS: The results were as follows. 1. Positive reactions with variable intensity using CK7, CKS, CK19 were seen in all cases(100%) of PD and the. staining intensity tor CK7 or CK19 was stronger than that of CKS. 2. Of the 12 cases of PD, both CK18 and CAM5.2 staining showed positivity in 11 cases(92%). 3. EMA and CEA staining showed positivity in 10(83%) and 9(75%) of 12 cases, respectively. 4. Some Pagets cells were negative for CK8, CK18 and EMA, although other positive cells were observed in the same sections. 5. All antigens were consistently negative in all cases of Bowens disease and superficial spreading melanoma in situ. CONCLUSION: The results show that moaoclonal antibodies to low molecular weight CKs are more sensitive than EMA or CEA in the demonstration of Pagets cells. Moreover, among the low molecular weight CK series, CK7 and CK19 are most useful for their high sensitivity and intensity.
Antibodies
;
Antibodies, Monoclonal
;
Biotin
;
Bowen's Disease
;
Coloring Agents
;
Diagnosis
;
Melanoma
;
Molecular Weight
;
Skin
;
Streptavidin