1.Cause analysis of failure to IOL implantation during cataract surgery
Suyun LIANG ; Jin ZHUANG ; Qin LUO
Recent Advances in Ophthalmology 2001;21(3):207-208
Objective To study the causes of failure to IOL implantation during cataract surgery.Methods We reviewed 540 eyes in which 23 eyes were failed to implant IOL during cataract surgery.Results Detachment of suspended zonular ligament, rupture of posterior capsule and vitreous prolapse are the main factors influencing IOL implantation during cataract surgery.Conclusion Improvement of surgical technique and reduction of complications are the key points for the IOL implantation successfully during cataract surgery.
2.The role of spatio-temporal image correlation with tomographic ultrasound imaging in the prenatal diagnosis of conotruncal defects
Jin XU ; Yihua HE ; Zhian LI ; Shicheng QIN ; Heli LI ; Lijuan ZHAO ; Xiuli ZHANG ; Suyun HOU
Chinese Journal of Ultrasonography 2012;(12):1026-1030
Objective To investigate the application value of spatio-temporal image correlation (STIC) combined with tomographic ultrasound imaging(TUI) in the prenatal diagnosis of conotruncal defects(CTD).Methods Two-dimensional(2D) fetal echocardiography to screen and TUI-STIC volumes from 1508 cases of fetuses of high risk with congenital heart disease.Postnatal work-up and pathological results were available for all fetuses with CTD.Results Thirty nine cases with CTD were found by TUI-STIC while thirty five cases were found by 2D echocardiography,but TUI-STIC had new findings and corrected the diagnosis in 9 cases as compared with 2D echocardiography.The sensitivity,specificity,positivity predictive value,negative predictive value and accuracy of TUI-STIC in evaluating CTD were 97.5 %,100%,100 %,99.9 % and 99 %.The Kappa value of consistency test between 2DE and TUI-SIC was 0.244(P < 0.01),McNemar test showed that the difference was statistically significant (P < 0.01).Conclusions TUI-STIC allows a complete sequential analysis of fetal conotruncal defects and supplying additional information over 2D fetal echocardiography,it could improve the prenatal diagnosis rate.TUI-STIC is helpful in diagnosis of prenatal conotruncal defects.
4.Effects of Chinese herbal medicine Dusuqing Granule on toll-like receptor 4 signaling in multiple organ injury induced by bacterial pneumonia in aged rats.
Shoufu WANG ; Huijian ZHANG ; Jiansheng LI ; Jinli QIN ; Suyun LI ; Haibin YU ; Feng WANG ; Ya LI ; Sihua LIU
Journal of Integrative Medicine 2011;9(1):84-90
To study the protective mechanism of Dusuqing Granule, a compound Chinese herbal medicine, on the senile multiple organ injury caused by bacterial pneumonia by observing the expression changes of molecules related to toll-like receptor 4 (TLR4) signaling.
5.Clinical characteristics of community-acquired influenza virus pneumonia in hospitalized children
Xirong WU ; Gang LIU ; Suyun QIAN ; Ju YIN ; Qiang QIN ; Jun LIU ; Xueli FENG ; Jianxin HE ; Yan GUO ; Zheng-De XIE ; Baoping XU
Chinese Journal of Applied Clinical Pediatrics 2019;34(2):129-133
Objective To analyze the clinical characteristics of community-acquired influenza virus pneumonia in hospitalized children and improve the clinicians' understanding level of this disease.Methods Data of 70 cases with community-acquired influenza virus pneumonia admitted to the Respiratory Department and Infectious Disease,Beijing Children's Hospital,Capital Medical University,from November 2009 to April 2018 were collected and the clinical characteristics were analyzed.Results Of the 70 cases,61 cases(89.7%) were discharged after improvement.The median age was 3.5 years old,and 50 cases(71.4%) were 0 to 5 years old.There were 29 cases with severe influenza pneumonia,41 cases with mild influenza pneumonia,3 cases died,and 19 cases (27.1%) had underlying diseases.Sixty-four cases (91.4%) were hospitalized in winter and spring.The first symptoms were mainly fever in 64 cases (91.4%) and cough in 65 cases (92.9%),and temperatures were mostly from 39.1 ℃ to 41.0 ℃.Lung auscultation was dominated by moist rales (30 cases,58.8%) and wheezing (8 cases,15.7%).There were many complications of influenza virus pneumonia,including 19 cases with myocardial injury,11 cases with liver function injury,4 cases with toxic encephalopathy,3 cases with electrolyte disturbance,2 cases with multiple organ failure,2 cases with hemophagocytic syndrome,and 1 case with septic shock.Chest radiographic results reveal bilateral inflammation in 40 children (57.1%),prodominatly in lower lobe lesions (39 cases).The common changes were patchy shadow,interstitial parenchymal lesion,ground glass shadow,and pleural effusion.Forty-seven children (67.1%) were infected by influenza A,and 23 children(32.9%) were co-infected.The percentage of severe cases with underlying diseases (68.4%) was significantly higher than that in children without chronic diseases (31.4%),the difference was statistically significant (x2 =7.830,P =0.005).The increase rate of C reaction protein (CRP) in severe cases (54.3%) was significantly higher than that in mild cases (28.6%),the difference was statistically significant (x2 =4.769,P =0.029).Conclusions Community-acquired influenza virus pneumonia in children mainly occurs in winter and spring.It is more common seen in children under 5 years of age.The main clinical manifestations of community-acquired influenza virus pneumonia are high fever and cough,extrapulmonary complications are more common.Most children have moist rales and showed bilateral inflammation and lower lobe lesions in chest radiography.Children with underlying diseases are more likely to develop severe influenza virus pneumonia.Elevated CRP is associated with severe influenza virus pneumonia.Most patients have a good prognosis,but there are still cases of death.
6.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.
7.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.