1.Bilateral Occipital Neuralgia in a Patient with Neurofibromatosis Type 1: A Case Report
Ji-Young KIM ; Sungmi JEON ; Sang Wha KIM
Korean Journal of Head and Neck Oncology 2021;37(2):77-80
Plexiform neurofibromas (PNFs) represent an uncommon variant (30%) of neurofibromatosis type 1 (NF-1), in which neurofibromas arise from multiple nerves as bulging and deforming masses involving connective tissue and skin folds. We report the case of a 17-year-old man with known NF-1 presenting with bilateral occipital neuralgia that began in his late adolescence. His chief complaint was radiating pain in the occiput induced by protective helmet wear when riding alpine skiing. Craniofacial magnetic resonance imaging (MRI) confirmed the presence of fusiform masses arising from the bilateral greater occipital nerves. Histopathological examination of the biopsy samples showed PNFs. After surgical treatment, the patient's symptoms completely improved. Unlike cutaneous neurofibromas, PNFs have different clinical characteristics and have the risk of malignant mutations. Correct diagnosis and adequate surgical treatment are necessary for PNFs.
2.Fiberoptic bronchoscope and C-MAC video laryngoscope assisted nasal-oral tube exchange: two case reports.
Sungmi JI ; Jaegyok SONG ; Seok Kon KIM ; Moon Young KIM ; Sangyun KIM
Journal of Dental Anesthesia and Pain Medicine 2017;17(3):219-223
In cases of multiple facial trauma and other specific cases, the anesthesiologist may be asked to convert an oral endotracheal tube to a nasal endotracheal tube or vice versa. Conventionally, the patient is simply extubated and the endotracheal tube is re-inserted along either the oral or nasal route. However, the task of airway management can become difficult due to surgical trauma or worsening of the airway condition. Fiberoptic bronchoscopy was considered a novel method of airway conversion but this method is not useful when there are secretions and bleeding in the airway, or if the anesthesiologist is inexperienced in using this device. We report a successful airway conversion under the aid of both, a fiberoptic bronchoscope and a C-MAC video laryngoscope.
Airway Management
;
Bronchoscopes*
;
Bronchoscopy
;
Hemorrhage
;
Humans
;
Intubation, Intratracheal
;
Laryngoscopes*
;
Methods
3.Efficacy of minimal invasive cardiac output and ScVO₂ monitoring during controlled hypotension for double-jaw surgery
Seokkon KIM ; Jaegyok SONG ; Sungmi JI ; Min A KWON ; Dajeong NAM
Journal of Dental Anesthesia and Pain Medicine 2019;19(6):353-360
BACKGROUND: Controlled hypotension (CH) provides a better surgical environment and reduces operative time. However, there are some risks related to organ hypoperfusion. The EV1000/FloTrac system can provide continuous cardiac output monitoring without the insertion of pulmonary arterial catheter. The present study investigated the efficacy of this device in double jaw surgery under CH.METHODS: We retrospectively reviewed the medical records of patients who underwent double jaw surgery between 2010 and 2015. Patients were administered conventional general anesthesia with desflurane; CH was performed with remifentanil infusion and monitored with an invasive radial arterial pressure monitor or the EV1000/FloTrac system. We allocated the patients into two groups, namely an A-line group and an EV1000 group, according to the monitoring methods used, and the study variables were compared.RESULTS: Eighty-five patients were reviewed. The A-line group reported a higher number of failed CH (P = 0.005). A significant correlation was found between preoperative hemoglobin and intraoperative packed red blood cell transfusion (r = 0.525; P < 0.001). In the EV1000 group, the mean arterial pressure (MAP) was significantly lower 2 h after CH (P = 0.014), and the cardiac index significantly decreased 1 h after CH (P = 0.001) and 2 h after CH (P = 0.007). Moreover, venous oxygen saturation (ScVO2) decreased significantly at both 1 h (P = 0.002) and 2 h after CH (P = 0.029); however, these values were within normal limits.CONCLUSION: The EV1000 group reported a lower failure rate of CH than the A-line group. However, EV1000/FloTrac monitoring did not present with any specific advantage over the conventional arterial line monitoring when CH was performed with the same protocol and same mean blood pressure. Preoperative anemia treatment will be helpful to decrease intraoperative transfusion. Furthermore, ScVO2 monitoring did not present with sufficient benefits over the risk and cost.
Anemia
;
Anesthesia, General
;
Arterial Pressure
;
Blood Pressure
;
Cardiac Output
;
Catheters
;
Erythrocyte Transfusion
;
Humans
;
Hypotension, Controlled
;
Medical Records
;
Operative Time
;
Orthognathic Surgery
;
Osteotomy, Le Fort
;
Oxygen
;
Retrospective Studies
;
Vascular Access Devices