1.Correlation between Bone Mineral Density Measured by Dual-Energy X-Ray Absorptiometry and Hounsfield Units Measured by Diagnostic CT in Lumbar Spine.
Sungjoon LEE ; Chun Kee CHUNG ; So Hee OH ; Sung Bae PARK
Journal of Korean Neurosurgical Society 2013;54(5):384-389
OBJECTIVE: Use of quantitative computed tomography (CT) to evaluate bone mineral density was suggested in the 1970s. Despite its reliability and accuracy, technical shortcomings restricted its usage, and dual-energy X-ray absorptiometry (DXA) became the gold standard evaluation method. Advances in CT technology have reduced its previous limitations, and CT evaluation of bone quality may now be applicable in clinical practice. The aim of this study was to determine if the Hounsfield unit (HU) values obtained from CT correlate with patient age and bone mineral density. METHODS: A total of 128 female patients who underwent lumbar CT for back pain were enrolled in the study. Their mean age was 66.4 years. Among them, 70 patients also underwent DXA. The patients were stratified by decade of life, forming five age groups. Lumbar vertebrae L1-4 were analyzed. The HU value of each vertebra was determined by averaging three measurements of the vertebra's trabecular portion, as shown in consecutive axial CT images. The HU values were compared between age groups, and correlations of HU value with bone mineral density and T-scores were determined. RESULTS: The HU values consistently decreased with increasing age with significant differences between age groups (p<0.001). There were significant positive correlations (p<0.001) of HU value with bone mineral density and T-score. CONCLUSION: The trabecular area HU value consistently decreases with age. Based on the strong positive correlation between HU value and bone mineral density, CT-based HU values might be useful in detecting bone mineral diseases, such as osteoporosis.
Absorptiometry, Photon*
;
Back Pain
;
Bone Density*
;
Female
;
Humans
;
Lumbar Vertebrae
;
Methods
;
Osteoporosis
;
Spine*
2.Elevated Carbohydrate Antigen 19-9 Level in a Patient with Horseshoe Type Pulmonary Sequestration.
Bub Se NA ; Sungjoon PARK ; Sukki CHO
The Korean Journal of Thoracic and Cardiovascular Surgery 2016;49(6):475-477
Elevated carbohydrate antigen (CA) 19-9 can indicate malignancies of the gastrointestinal, pancreatic, and biliary tracts, and be found in a pulmonary sequestration. A 30-year-old man visited Seoul National University Bundang Hospital due to elevated CA 19-9 levels, representing pulmonary sequestration of the bilateral lower lobes, which were connected with each other. We performed left lower lobectomy and division of the systemic arteries. After operation, CA 19-9 levels decreased to normal range, even though a small amount of sequestrated lung remained in the right lower lobe. It is not uncommon that presence of pulmonary sequestration might elevate serum CA 19-9 levels; however, horseshoe type bilateral pulmonary sequestration is very rare.
Adult
;
Arteries
;
Biliary Tract
;
Bronchopulmonary Sequestration*
;
Humans
;
Lung
;
Reference Values
;
Seoul
3.Supratentorial Intracerebral Schwannoma : Its Fate and Proper Management.
Sungjoon LEE ; Sung Hye PARK ; Chun Kee CHUNG
Journal of Korean Neurosurgical Society 2013;54(4):340-343
Intracerebral schwannomas are rare and there have been none reported in Korea. We present the case of a 25-year-old man with newly developed right-side weakness and recent seizure aggravation. His seizures started approximately 9 years prior to admission. At that time, a 1 cm diameter intra-axial enhancing mass at the left precentral gyrus was found on magnetic resonance image (MRI). After 9 years of observation and treatment with antiepileptic medication, an MRI taken due to symptom aggravation revealed peri-tumoral cyst formation with tumor enlargement. The tumor was surgically removed. Subsequently, right-side weakness diminished and there was good seizure control. Pathologic diagnosis was schwannoma. Schwannoma is a very rare tumor and there are no pathognomonic findings on radiologic images; thus, it is challenging to make a correct diagnosis. However, considering the natural course and excellent prognosis after surgical treatment of this kind of intra-axial mass with benign features, early surgery for diagnosis and proper treatment is highly recommended.
Adult
;
Diagnosis
;
General Surgery
;
Humans
;
Korea
;
Magnetics
;
Magnets
;
Neurilemmoma*
;
Prognosis
;
Seizures
4.Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device
Huijin LEE ; Sungjoon PARK ; Hyuktae KWON ; Belong CHO ; Jin Ho PARK ; Hae-Young LEE
Korean Circulation Journal 2024;54(2):93-104
Background:
s and Objectives: This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM).
Methods:
Forty patients were recruited, and 33 participants were included in the final analysis.Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements.
Results:
The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg.Mean differences in SBP/DBP between the two devices were 1.74±6.69/−3.24±6.51 mmHg, 0.75±7.44/−4.41±7.42 mmHg, and 4.15±6.15/−0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001).
Conclusions
The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.
5.Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device
Huijin LEE ; Sungjoon PARK ; Hyuktae KWON ; Belong CHO ; Jin Ho PARK ; Hae-Young LEE
Korean Circulation Journal 2024;54(2):93-104
Background:
s and Objectives: This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM).
Methods:
Forty patients were recruited, and 33 participants were included in the final analysis.Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements.
Results:
The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg.Mean differences in SBP/DBP between the two devices were 1.74±6.69/−3.24±6.51 mmHg, 0.75±7.44/−4.41±7.42 mmHg, and 4.15±6.15/−0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001).
Conclusions
The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.
6.Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device
Huijin LEE ; Sungjoon PARK ; Hyuktae KWON ; Belong CHO ; Jin Ho PARK ; Hae-Young LEE
Korean Circulation Journal 2024;54(2):93-104
Background:
s and Objectives: This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM).
Methods:
Forty patients were recruited, and 33 participants were included in the final analysis.Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements.
Results:
The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg.Mean differences in SBP/DBP between the two devices were 1.74±6.69/−3.24±6.51 mmHg, 0.75±7.44/−4.41±7.42 mmHg, and 4.15±6.15/−0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001).
Conclusions
The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.
7.Association of epicardial adipose tissue with metabolic risk factors on cardiovascular outcomes: serial coronary computed tomography angiography study
Sungjoon PARK ; Dong Eun KIM ; Su Min KIM ; JungMin CHOI ; Sang Joon PARK ; Hae-Young LEE ; Eun Ju CHUN
The Korean Journal of Internal Medicine 2024;39(2):283-294
Background/Aims:
Epicardial adipose tissue (EAT) shares pathophysiological properties with other visceral fats and potentially triggers local inflammation. However, the association of EAT with cardiovascular disease (CVD) is still debatable. The study aimed to observe the changes and associations in EAT and risk factors over time, as well as to investigate whether EAT was associated with CVD.
Methods:
A total of 762 participants from Seoul National University Hospital (SNUH) and SNUH Gangnam Center were included in this study. EAT was measured using coronary computed tomography angiography.
Results:
Baseline EAT level was positively associated with body mass index (BMI), calcium score, atherosclerotic cardiovascular disease (ASCVD) 10-year risk score, glucose, triglycerides (TG)/high-density lipoprotein (HDL), but not with total cholesterol, low-density lipoprotein (LDL). At follow-up, EAT levels increased in all groups, with low EAT groups demonstrating a significant increase in EAT per year. Change in EAT was associated with a change in BMI, TG/HDL, and glucose, while changes in LDL, calcium score, and ASCVD 10-year risk score were not associated. Although calcium score and ASCVD 10-year risk score were associated with CVD events, baseline information of EAT, baseline EAT/body surface area, or EAT change was not available.
Conclusions
Metabolic risks, e.g., BMI, TG/HDL, and glucose, were associated with EAT change per year, whereas classical CVD risks, e.g., LDL, calcium score, and ASCVD 10-year risk score, were not. The actual CVD event was not associated with EAT volume, warranting future studies combining qualitative assessments with quantitative ones.
8.Change in Plantar Pressure and Plain Radiography in Pediatric Flexible Flatfoot: A Retrospective Cohort Study
Sungjoon KIM ; Yong Gyun KIM ; Jun Yup KIM ; Si-Bog PARK ; Kyu Hoon LEE
Annals of Rehabilitation Medicine 2024;48(5):352-359
Objective:
To investigate longitudinal changes in plantar pressure examinations and plain radiographs and to assess the correlations between these two modalities in pediatric patients with flexible flatfoot (FFF).
Methods:
Pediatric patients diagnosed with FFF were analyzed in this retrospective cohort study. Medical records were reviewed to collect data on plain radiographs and plantar pressure examinations. Changes in radiographic angles and plantar pressure parameters were analyzed over a follow-up period exceeding 1 year. Statistical analyses included paired t-test, Wilcoxon signed rank test, and Spearman’s correlation analysis.
Results:
A total of 52 subjects was included in the plantar pressure analysis, with a mean age of 9.9 years at the first visit and a median follow-up duration of 52 months. The lateral tarso-first metatarsal angle decreased by 1.3° (p<0.001) and calcaneal inclination angle increased by 2.5° (p<0.001) in these patients. The percentage value of midfoot width (WMF) divided by forefoot width (WFF) decreased by an average of 9.8% p (p<0.001), and the maximal pressure on the medial midfoot (MMF) decreased by 1.6 N/cm2 (p<0.001). However, no correlations were found between plantar pressure and radiographic changes.
Conclusion
During follow-up of patients with FFF, the maximal pressure on the MMF and the ratio of WMF to WFF decreased in successive plantar pressure examinations. Changes observed in plantar pressure and plain radiographs were not consistent, indicating that these two testing modalities can complement each other.
9.Change in Plantar Pressure and Plain Radiography in Pediatric Flexible Flatfoot: A Retrospective Cohort Study
Sungjoon KIM ; Yong Gyun KIM ; Jun Yup KIM ; Si-Bog PARK ; Kyu Hoon LEE
Annals of Rehabilitation Medicine 2024;48(5):352-359
Objective:
To investigate longitudinal changes in plantar pressure examinations and plain radiographs and to assess the correlations between these two modalities in pediatric patients with flexible flatfoot (FFF).
Methods:
Pediatric patients diagnosed with FFF were analyzed in this retrospective cohort study. Medical records were reviewed to collect data on plain radiographs and plantar pressure examinations. Changes in radiographic angles and plantar pressure parameters were analyzed over a follow-up period exceeding 1 year. Statistical analyses included paired t-test, Wilcoxon signed rank test, and Spearman’s correlation analysis.
Results:
A total of 52 subjects was included in the plantar pressure analysis, with a mean age of 9.9 years at the first visit and a median follow-up duration of 52 months. The lateral tarso-first metatarsal angle decreased by 1.3° (p<0.001) and calcaneal inclination angle increased by 2.5° (p<0.001) in these patients. The percentage value of midfoot width (WMF) divided by forefoot width (WFF) decreased by an average of 9.8% p (p<0.001), and the maximal pressure on the medial midfoot (MMF) decreased by 1.6 N/cm2 (p<0.001). However, no correlations were found between plantar pressure and radiographic changes.
Conclusion
During follow-up of patients with FFF, the maximal pressure on the MMF and the ratio of WMF to WFF decreased in successive plantar pressure examinations. Changes observed in plantar pressure and plain radiographs were not consistent, indicating that these two testing modalities can complement each other.
10.Change in Plantar Pressure and Plain Radiography in Pediatric Flexible Flatfoot: A Retrospective Cohort Study
Sungjoon KIM ; Yong Gyun KIM ; Jun Yup KIM ; Si-Bog PARK ; Kyu Hoon LEE
Annals of Rehabilitation Medicine 2024;48(5):352-359
Objective:
To investigate longitudinal changes in plantar pressure examinations and plain radiographs and to assess the correlations between these two modalities in pediatric patients with flexible flatfoot (FFF).
Methods:
Pediatric patients diagnosed with FFF were analyzed in this retrospective cohort study. Medical records were reviewed to collect data on plain radiographs and plantar pressure examinations. Changes in radiographic angles and plantar pressure parameters were analyzed over a follow-up period exceeding 1 year. Statistical analyses included paired t-test, Wilcoxon signed rank test, and Spearman’s correlation analysis.
Results:
A total of 52 subjects was included in the plantar pressure analysis, with a mean age of 9.9 years at the first visit and a median follow-up duration of 52 months. The lateral tarso-first metatarsal angle decreased by 1.3° (p<0.001) and calcaneal inclination angle increased by 2.5° (p<0.001) in these patients. The percentage value of midfoot width (WMF) divided by forefoot width (WFF) decreased by an average of 9.8% p (p<0.001), and the maximal pressure on the medial midfoot (MMF) decreased by 1.6 N/cm2 (p<0.001). However, no correlations were found between plantar pressure and radiographic changes.
Conclusion
During follow-up of patients with FFF, the maximal pressure on the MMF and the ratio of WMF to WFF decreased in successive plantar pressure examinations. Changes observed in plantar pressure and plain radiographs were not consistent, indicating that these two testing modalities can complement each other.