1.Comparison between Planar View and SPECT View on the Dipyridamole Thallium 201 Myocardial Perfusion Scintigraphy.
Sung Yub YEO ; Jeong Pyo JANG ; Hong JOO ; Hong Bum KIM ; Jong Han OK ; Dong Ryong SEO ; You Soon CHAE
Korean Circulation Journal 1988;18(2):207-220
Exercise testing with Thallium imaging is widely used for the noninvasive evaluation of patients suspected of having coronary artery disease. However, many patients referred for stress testing connot exercise adequately for either physical or psychological reasons, and as a result may have nondiagnostic or suboptimal test results. Intravenous dipyridamole in conjunction with Thallium imaging is as effective alternative method without exercise. But, myocardial imaging using the standard scintillation camera technique(planner view) is hampered by superposition of proximal & distal cardial walls and by the segmental nature of myocardial ischemia. For this reason, Single Photon Emission Computed Tomography(SPECT) reslut in high specificity & sensitivity rates for the detection of coronar artery disease compared with conventional technique. So we performed dipyridamole Th-201 myocardial scintigraphy on 25 subjects who have suspicious angina or myocardial infarction instead of exercise Th-201 myocardial scintigraphy, and compared SPECT view with conventional plannar view. The results obtained are as follows : 1) T1-201 scintigraphic findings in 17 patients with suspicious angina were as follows ; redistribution defect was seen in 4 cases in plannar view and 13 cases in SPECT view. 2) T1-201 scintigraphic findings in 8 patients with myocardial infarction were as follows ; in planner view, perfusion defect was seen in all cases and 1 cases of them, redistribution defect was accompained, and in SPECT view, perfusion defect was seen in all cases and 6 cases of them, redistribution defect was accompained. 3) During dipyridamole infusion, the mean systolic & diatolic pressure decreased from 133+/-22.7/86+/-13.5 to 121+/-23.9/78+/-13.1mmHg and the heart rate increased from 68+/-12.4 to 84+/-12.4beats/min. 4) Adverse effects of dipyridamole were noted in 14(56%) of the subjects, but in 12 of these, the symptoms were mild in severity and subsided spontanously. To summarize, Dipyridamole-201 myocardial imaging is a useful and test for coronary artery disease, and the new tomographic technique, SPECT view, is more useful than the conventional plannar view.
Arteries
;
Coronary Artery Disease
;
Dipyridamole*
;
Exercise Test
;
Gamma Cameras
;
Heart Rate
;
Humans
;
Myocardial Infarction
;
Myocardial Ischemia
;
Myocardial Perfusion Imaging
;
Perfusion Imaging*
;
Perfusion*
;
Sensitivity and Specificity
;
Thallium*
;
Tomography, Emission-Computed, Single-Photon*
2.Development of a canine model for recurrent laryngeal injury by harmonic scalpel.
Kyu Eun LEE ; Hyeon Gun JEE ; Hoon Yub KIM ; Won Seo PARK ; Sung Hye PARK ; Yeo Kyu YOUN
Laboratory Animal Research 2012;28(4):223-228
Various energy devices had been used in thyroid surgery. Aim of study is to develop canine model for recurrent laryngeal nerve injury by harmonic scalpel and to evaluate feasibility of using this model for evaluating the safety use of harmonic scalpel during thyroid surgery. Nine dogs were divided into 3 groups according to distance between harmonic scalpel application and recurrent laryngeal nerve; group 1 (1 mm), 2 (2 mm), and 3 (3 mm). Vocal cord function was assessed pre- and postoperatively using video laryngoscopy. Harmonic scalpel was applied adjacent to left recurrent laryngeal nerve and, two weeks later, right recurrent laryngeal nerve at assigned distances. Recurrent laryngeal nerves were evaluated for subacute and acute morphologic changes. Laryngoscopy demonstrated 3 abnormal vocal cords in group 1, 1 in group 2, and no in group 3 (P=0.020). Subacute histologic changes were observed in nerves with abnormal function. Acute histologic changes were observed 5/8 (62.5%) in group 1, 1/7 (14.3%) in group 2, and not in group 3. We developed canine model for recurrent laryngeal injury. The functional outcomes matched with the histologic changes. These warrant further study to determine the safety margin for energy device in vicinity of recurrent laryngeal nerve.
Animals
;
Dogs
;
Laryngoscopy
;
Recurrent Laryngeal Nerve
;
Recurrent Laryngeal Nerve Injuries
;
Thyroid Gland
;
Vocal Cords