1.Quadricepsplasty and arthrolysis in stiff knee.
Sung Won SOHN ; Woo Yul LEE ; Byung Woo MIN
Journal of the Korean Knee Society 1992;4(1):69-79
No abstract available.
Knee*
2.Gluteus Maximus Myocutaneous Flaps for Repair of the Sacral Pressure Sores
Chang Soo KANG ; Sung Won SOHN ; Byung Woo MIN
The Journal of the Korean Orthopaedic Association 1987;22(6):1361-1366
It would be naive to assume that any operative procedure is the solution to the problem of sacral pressure sore in the field of the orthopaedic surgery. The procedures outlined here involve the creation of compound myocutaneous flaps of the gluteus maximus muscle, skin, and the subcutaneous tissue. The myocutaneous flap us- ing the gluteus maximus muscle is a vascular flap instead of a random flap, with better blood supply for healing and advantage of an increased amount of cushion effect. We present an alternative method which will provide satisfactory and substantial soft tissue coverage in sscral pressure sores.
Methods
;
Myocutaneous Flap
;
Pressure Ulcer
;
Skin
;
Subcutaneous Tissue
;
Surgical Procedures, Operative
3.A case of acute megakaryoblastic leukemia with Down syndrome.
Sung Jin CHANG ; Sung Min SOHN ; Heung Sik KIM ; Chin Moo KANG ; Dong Seok JEON
Journal of the Korean Pediatric Society 1991;34(12):1730-1735
No abstract available.
Down Syndrome*
;
Leukemia, Megakaryoblastic, Acute*
4.Hypoxic-Ischemic Encephalopathy Following Carotid Endarterectomy.
Journal of the Korean Neurological Association 2013;31(2):136-137
No abstract available.
Carotid Stenosis
;
Endarterectomy, Carotid
;
Hypoxia-Ischemia, Brain
5.Autophor ceramic total hip arthroplasty: thirteen hips followed-up more than five years.
Ju Hai CHANG ; Jong Min SOHN ; Kyung Hwan CHOI ; Je Sung LEE
The Journal of the Korean Orthopaedic Association 1991;26(6):1735-1743
No abstract available.
Arthroplasty, Replacement, Hip*
;
Ceramics*
;
Hip*
6.Treatment of Blepharoptosis Using Variable Operative Techniques.
Ho Sung SOHN ; Jung Min PARK ; Si Hyun PARK ; Seok Kwun KIM
Journal of the Korean Society of Aesthetic Plastic Surgery 2001;7(1):40-46
No abstract available.
Blepharoptosis*
7.Arteriovenous Fistula follwing Lumbar Discectomy
Sung Keun SOHN ; Jae Do KIM ; Woo Min JEONG ; Dong Seung LEE
The Journal of the Korean Orthopaedic Association 1989;24(1):299-303
Arteriovenous fistula could occur rarely followed by lumbar disk operation. There are very few case reports in the literature. We have experienced a case of arteriovenous fistula, which has been corrected surgically.
Arteriovenous Fistula
;
Diskectomy
8.Effects of Colloidal Gold 198Au on Synovial Membrane of Rabbits
Sung Keun SOHN ; Jae Do KIM ; Woo Min JEONG ; Jae Ik LEE
The Journal of the Korean Orthopaedic Association 1989;24(2):607-612
Colloidal gold 198Au were injected into 40 knee joints of rabbits for the study of the change of synovial membrane. We verified even distribution of Colloidal gold 198Au about knee joints by use of scintigraphy. After then, histopathological examinations were performed by periodic intervals. The following results are obtained form this study. l. Intra-articular injection of Colloidal gold 198Au into rabbit's knee joints resulted in a mild resctive inflammation at synovium. In was charscterized by an infiltration of eosinophils and by sclerotic changes in the subsynovium and by fibrosis of synovial vessels. 2. From this study, intra-articular injection of Colloidal gold 198Au may by benefit to treat the chronic synovial effusion in human.
Colloids
;
Eosinophils
;
Fibrosis
;
Gold Colloid
;
Humans
;
Inflammation
;
Injections, Intra-Articular
;
Knee Joint
;
Rabbits
;
Radionuclide Imaging
;
Synovial Membrane
9.Motion Study in the Fused Lumbar Spine
Sung Keun SOHN ; Jae Do KIM ; Woo Min JEONG ; Jae Ho JANG
The Journal of the Korean Orthopaedic Association 1989;24(2):523-531
In fusion of lumbar spine, every fused motion segments shows varisble limitation of motion in flexion, extension and lateral bending according to their types and level of fusion. The motion segment of lumbar spine is three joint complex which consists of posterior two articular facet joints and an anterior intervertebral disc. Nowadays, orthopedic surgeon prefer anterior fusion due to direct identification and removal of diseased tissue, reduction of fractured fragments, restoration of intrevertebral space, early rehabilitation and no damage of nerve root and cord, and is prefered short Segmental Spinal Instrumentation(e.g. Cotrel Dubousset Instrumentation, etc.) due to short and rigid fusion, no necessity of external support and low limitation of motion. We studied 58 cases of fused lumbar spine which had been operated since Sep.1983, by X-ray overlay method and 20 cases of healthy lumbar spine as eontrol group. In this study, we obtained following results ; 1. Harrington Rod Instrumentation reveals the most remarkable limitation of motion, whereas, C.D.I. and A.I.F. reveal the least limitation of motion. 2. Distinct differencies of motion are repersented by its range of fusion and range of motion in 2 segmental fusion reveals remarkable decreasement from range of motion in single segmental fusion. 3. In single segmental fusion, the most limitation of motion was represented in Harrington Rod Instrumentation and posterior fusion with bone graft. There is remarkable decreasement of flexion at lumbosacral junction by its site of fusion. 4.In double segmental fusion, the most limitation of motion was represented in Harrington Rod Instrumentation and there is no significant difference of motion by its site of fusion.
Intervertebral Disc
;
Joints
;
Methods
;
Orthopedics
;
Range of Motion, Articular
;
Rehabilitation
;
Spine
;
Transplants
;
Zygapophyseal Joint
10.Detachable zirconia prosthesis using Milled bar and ADDTOC attachment in partial edentulous mandible: A case report
The Journal of Korean Academy of Prosthodontics 2023;61(1):90-99
Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADDTOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.