2.THE EFFECT OF Ti ON THE SHEARBONDING STRENGTH BEWEEN DENTAL PORCELAIN AND Ni-Cr NONPRECIOUS ALLOY.
The Journal of Korean Academy of Prosthodontics 1997;35(2):413-416
A study of the shear bond strength between dental porcelain and alloy in Ti depostion effect was conducted by Instron universal testing machine. The obtained result was as follows ; The shear bond strength of Ti-depostion group and acid-etched group were statiscally significantly greater than that of untreated control group (p<0.01)
Alloys*
;
Dental Porcelain*
3.On the effects of the characteristics of the titanium oxide to the osteoblast cell culture.
The Journal of Korean Academy of Prosthodontics 2000;38(3):358-359
STATEMENT of PROBLEM: Confusion about the relationship of surface characteristics of implant to osteoblast cell attachment. PURPOSE: This study attempted to bone cell attachment to the implant surface which was modified by heat. MATERIAL AND METHODS: Commercially pure titanium grade 2, 4x4mm sheet 40 pieces were treated for 10 minutes with ultrasonic cleaner with methylethyl ketone, ethanol, deionized distilled water, and half of the specimen 20 pieces were heat treated in 980degreesC for 15 minutes. All 40 specimens were autoclaves. Total 6 dishes were prepared, 3 dishes were for control group, and the other 3 dishes were for heat treatment. In fourth day, cell account was done. CONCULSION: The change of surface characterization by heat treatment could affect the cell attachment in the early stage however, the change of surface characterization would not be prolonged.
Cell Culture Techniques*
;
Ethanol
;
Hot Temperature
;
Osteoblasts*
;
Titanium*
;
Ultrasonics
;
Water
4.A clincal study of Kennedy classification and framework design of removable partial denture in Kyungpook National University hospital.
Phill Seon CHA ; In Yeong JEONG ; Sung Am CHO
The Journal of Korean Academy of Prosthodontics 2010;48(3):189-193
PURPOSE: This study was aimed to investigate the frequency of different classes of partial edentulism and the most frequently used design components of conventional removable partial dentures. MATERIALS AND METHODS: 63 patients who were treated with removable partial denture in Kyungpook National University hospital for 2003 - 2006 were selected. A total of 76 removable partial denture frameworks were investigated. Kennedy classification was used to identify the class of partial edentulism. RESULTS: Results indicated that Kennedy class I removable partial dentures were the most frequently constructed. Most patients'cases were designed without modification areas. CONCLUSION: The most common type of direct retainer were the RPI clasp and RPA clasp in both maxilla and mandible. Lingual bar, linguoplate and anterior posterior palatal straps were the more frequently used mandibular and maxillary major connectors respectively. We did not have any case about Kennedy class IV patients.
Denture, Partial, Removable
;
Humans
;
Mandible
;
Maxilla
5.Comparison of removal torque of saline-soaking RBM implants and RBM implants in rabbit tibias
The Journal of Korean Academy of Prosthodontics 2018;56(1):1-7
PURPOSE: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM surface treatment. MATERIALS AND METHODS: The control group was RBM surface treated implants (RBM), and the test group was implants soaked in saline for 2 weeks after RBM surface treatment (RBM+Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. RESULTS: There was no significant difference in insertion torque and removal torque between RBM surface treated titanium implants and saline-soaked titanium implants after RBM surface treatment. CONCLUSION: Saline soaking after RBM surface treatment of titanium implants did not positively affect the initial osseointegration as compared to titanium implants with only RBM surface treatment.
Hydroxyapatites
;
Osseointegration
;
Rabbits
;
Sodium Chloride
;
Spectrum Analysis, Raman
;
Tibia
;
Titanium
;
Torque
6.Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias
The Journal of Korean Academy of Prosthodontics 2019;57(4):335-341
PURPOSE: Chemically strong-acids (HF and HCl/H₂SO₄) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. MATERIALS AND METHODS: Nine 3.75 × 4 mm dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. RESULTS: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were 0.93 µm for HS group and 0.84 µm for H group (P=.170). Root mean square roughness (RSq) values were 1.21 µm for HS group and 1.08 µm for H group (P=.294), and mean wetting angle values were 99° for HS group and 98° for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. CONCLUSION: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.
Fatigue
;
Osseointegration
;
Rabbits
;
Sulfur
;
Tibia
;
Titanium
;
Torque
7.The effects of saline soaking on the removal torque of titanium implants in rabbit tibia after 10 days
The Journal of Korean Academy of Prosthodontics 2019;57(4):328-334
PURPOSE: The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque of each implant that inserted in rabbit tibia for initial healing period of 10 days. MATERIALS AND METHODS: Twenty machined titanium surface screws were produced with a diameter 3 mm, length 8 mm. Ten screws had their surface treated with a laser only (laser treated group), and the other 10 were soaked in saline for 2 weeks after surface treatment with a laser (laser treated + saline soaked group). Implants were inserted in rabbit tibia (ten adult New Zealand white rabbits), and the RTQ of each implant was measured after 10 days. The wettability among implants was compared by measuring the contact angle. Surface composition and surface topography were analyzed. RESULTS: After 10 days, the laser treat + soaking group implants had a significantly higher mean RTQ than the laser treated implants (P = .002, < .05). There were no significant morphological differences between groups, and no remarkable differences were found between the two groups in the SEM analysis. CONCLUSION: Saline soaking implants is expected to produce excellent RTQ and surface analysis results.
Adult
;
Humans
;
Hydrophobic and Hydrophilic Interactions
;
New Zealand
;
Tibia
;
Titanium
;
Torque
;
Wettability
8.On the effect of saline immersion to the removal torque for resorbable blasting media and acid treated implants
Journal of Dental Rehabilitation and Applied Science 2018;34(1):1-9
PURPOSE: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM and acid etched surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM and acid etched surface treatment. MATERIALS AND METHODS: The control group was RBM and acid etched surface treated implants (RBM + HCl), and the test group was implants soaked in saline for 2 weeks after RBM and acid etched surface treatment (RBM + HCl + Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. RESULTS: There was significant difference in insertion torque and removal torque between control group and experimental group (P = 0.014 < 0.05). Surface roughness of experimental group is higher than control group. CONCLUSION: Saline soaking after RBM and acid etched surface treatment of titanium implants were positively affect the initial osseointegration as compared to titanium implants with only RBM and acid etched surface treatment.
Hydroxyapatites
;
Immersion
;
Osseointegration
;
Rabbits
;
Sodium Chloride
;
Spectrum Analysis, Raman
;
Tibia
;
Titanium
;
Torque
9.Success and survival rate of the implant with crestal sinus lift using S-reamer and gel-type graft material: A retrospective study by more 5-years follow check up
The Journal of Korean Academy of Prosthodontics 2020;58(1):23-29
PURPOSE: The purpose of this retrospective study was to evaluate the method using the S-reamer and gel-type graft material by the success rate and survival rate.MATERIALS AND METHODS: Implantation period was from 2008 to 2014, Follow check up year is 2019. There were 59 patients and 117 implants. All implants were placed in the posterior maxilla with the sinus lift. The patients population consisted of 34 men and 25 women, ranging from 19 to 75 years. The residual bone heights were from 1 mm to 6 mm. Sinus was perforated with S-reamer without membrane tearing and gel type bone graft material was used for membrane lifting and filling the space. all implants were placed simultaneously. Panoramic X-ray was taken. After 5 – 6 months healing period, final prostheses were restored. After more 5-years implant surgery, Panoramic X-ray was obtained and X-ray analysis and clinical examination were performed. Success criteria was referred to a Buser's success critera. All implants were classified to success implant, survival implant, failed implant. A success implant was satisfying success criteria, a survival implant was a implant that was acute infection with suppuration and bone loss, a failed implant was a implant that was mobile, removed.RESULTS: Five implants were removed, and 4 implants had infected with bone loss. Survival rate was 95.7% and success rate was 92.3%.CONCLUSION: This retrospective study presented that this method with S-reamer and gel-type graft material was a successful treatment without membrane tear in the condition of 1-6 mm residual bone height.
Female
;
Humans
;
Lifting
;
Male
;
Maxilla
;
Membranes
;
Methods
;
Prostheses and Implants
;
Retrospective Studies
;
Suppuration
;
Survival Rate
;
Tears
;
Transplants
10.The influence of systemically administered oxytocin on the implant-bone interface area: an experimental study in the rabbit.
Sung Am CHO ; Sang Hun PARK ; Jin Hyun CHO
The Journal of Advanced Prosthodontics 2014;6(6):505-511
PURPOSE: The purpose of this study was to assess the effect of systemically administered oxytocin (OT) on the implant-bone interface by using histomorphometric analysis and the removal torque test. MATERIALS AND METHODS: A total of 10 adult, New Zealand white, female rabbits were used in this experiment. We placed 2 implants (CSM; CSM Implant, Daegu, South Korea) in each distal femoral metaphysis on both the right and left sides; the implants on both sides were placed 10 mm apart. In each rabbit, 1 implant was prepared for histomorphometric analysis and the other 3 were prepared for the removal torque test (RT). The animals received intramuscular injections of either saline (control group; 0.15 M NaCl) or OT (experimental group; 200 microg/rabbit). The injections were initiated on Day 3 following the implant surgery and were continued for 4 subsequent weeks; the injections were administered twice per day (at a 12-h interval), for 2 days per week. RESULTS: While no statistically significant difference was observed between the two groups (P=.787), the control group had stronger removal torque values. The serum OT concentration (ELISA value) was higher in the OT-treated group, although no statistically significant difference was found. Further, the histomorphometric parameter (bone-toimplant contact [BIC], inter-thread bone, and peri-implant bone) values were higher in the experimental group, but the differences were not significant. CONCLUSION: We postulate that OT supplementation via intramuscular injection weakly contributes to the bone response at the implant-bone interface in rabbits. Therefore, higher concentrations or more frequent administration of OT may be required for a greater bone response to the implant. Further studies analyzing these aspects are needed.
Adult
;
Animals
;
Daegu
;
Dental Implants
;
Female
;
Humans
;
Injections, Intramuscular
;
New Zealand
;
Oxytocin*
;
Rabbits
;
Torque