1.HIV-, HBV- and HCV- NAT yield in individual donations: a multi-center analysis in Henan province from 2017 to 2019
Yan ZHANG ; Jianhua FANG ; Wenchao GE ; Yifang WANG ; Qi JIANG ; Shanhua CHEN ; Dan CHEN ; Jia WU ; Nan CHEN ; Yu MENG ; Huiyun HAN ; Dengfeng WANG ; Xiaozhen ZHANG ; Yue ZHANG ; Fengyong MA ; Bin JIA ; Weijie LI ; Sili SUN ; Fei ZHAO ; Yongqing ZHOU ; Suneng ZHANG
Chinese Journal of Blood Transfusion 2021;34(1):68-72
【Objective】 To analyze the HIV-, HCV- and HBV- NAT yield rate in different areas of Henan province, so as to provide the basis for disease prevention and control as well as the establishment of a unified quality control standard for nucleic acid testing(NAT) in the Henan province. 【Methods】 The number and prevalence of NAT yielding samples with isolated infectious virus, namely HIV, HCV and HBV, in 18 blood stations in Henan province from 2017~2019, as well as the trends were analyzed. The NAT quality of each laboratory and each testing system was analyzed according to the ratio of reactive individual donation(ID) results to reactive minipools(MP). 【Results】 The HBV, HCV and HIV ID-NAT yield numbers in 3 501 251 blood donations were HBV 2 606(74/100 000), HCV 21 (0.63/100 000), and HIV 34(1.00/100 000). The HBV ID-NAT yield rate showed an upward trend in the whole province from 2017 to 2019, while the prevalence of HIV and HCV ID-NAT yield didn′t differ significantly during three years. 5 kinds of NAT detection systems were applied in 18 blood centers. among which Ⅰ, Ⅱ, Ⅳ and Ⅴ were triplex detection systems. 2661 ID-reactive samples were implicated in 5 595 MP-reactive samples, with a resolution rate of 47.56%. The resolution rate of triplex NAT system Ⅰ, Ⅱ, Ⅳ and Ⅳ was 39.63%~47.95%, 40.43%~54.36%, 51.61% and 70.00%~45.45%, respectively. An upward trend in triplex NAT resolution rate was observed in 8 laboratories, i. e.B, D, E, F, I, K, L and Q, and an descending trend in A and C. The NAT system Ⅲ, a ID-NAT system, was used only by laboratory C, presenting a NAT-yield rate of 0.19% (282/145 474) and resolution rate of 46.45% (131/282). 【Conclusion】 The majority of NAT-yield of one infectious virus in Henan province is HBV, presenting annual increasing trend. The quality management of NAT laboratories should be strengthened as the divergence was seen in the performance of different NAT laboratories.
2.Single-ELISA reactive rate of four blood screening items in 18 blood station laboratories: Henan, 2019
Yan ZHANG ; Mingjun CHEN ; Hongna ZHAO ; Yonglei LV ; Jianhua FANG ; Qi JIANG ; Shanhua CHEN ; Dan CHEN ; Jia WU ; Nan CHEN ; Yu MENG ; Huiyun HAN ; Dengfeng WANG ; Xiaozhen ZHANG ; Yue ZHANG ; Fengyong MA ; Bin JIA ; Junjie LI ; Sili SUN ; Fei ZHAO ; Yongqing ZHOU ; Suneng ZHANG
Chinese Journal of Blood Transfusion 2021;34(8):878-882
【Objective】 To analyze the cause of single-ELISA reactive of four blood screening items in 18 blood stations in Henan, so as to provide the basis for improving the quality of blood screening. 【Methods】 The single-ELISA reactive rate of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP of 18 blood station laboratories in Henan throughout 2019 was calculated, and the causes were analyzed according to different ELISA reagent combinations and gray area settings in each laboratory. 【Results】 The overall single-ELISA reactive rates of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP were 1.740(2 154/1 237 789), 0.564‰(698/1 237 789), 1.421‰(1 759/1 237 789) and 1.561‰(1 932/1 237 789), respectively, showing significant differences by detection items (P <0.05). Person correlation analysis showed that the single-ELISA reactive rate was independent of the gray area settings.but dependent on laboratories and reagent combinations. The single-ELISA reactive rate of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP in D laboratory was the highest and higher than that in other labs using the same reagent.The laboratories with high HBsAg single-ELISA reactive rate were mostly those using a combination of imported reagents and domestic reagents, including the top 6 laboratories. The laboratories with high anti-HCV single-ELISA reactive rate were mostly those using certain domestic reagents. No obvious rules was noticed by single-ELISA reactive for anti-HIV. Laboratories with high anti-TP single-ELISA reactive rate were mostly those using combination 4. 【Conclusion】 The HBsAg single-ELISA reactive rate was the highest in the four blood screening items of blood station laboratories in Henan. The single-ELISA reactive rate is related to the laboratory itself and the reagent manufacturer, suggesting that laboratory quality control should be strengthened and proper reagent combination should be selected to reduce the waste of blood.