1.3D Mapping Software Development for 128ch. ECG system.
Journal of Korean Society of Medical Informatics 2002;8(4):63-67
The ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 128 channel computerized data analysis system using microcomputer for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 128 cardiac sites simultaneously at a sampling rate of 1 ksampls/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point is displayed on three dimensional diagram of the heart. System design permits easy expansion to almost 256 simul- taneous sites. This system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the result of diagnosis and surgical treatment for cardiac arrhythmia.
Arrhythmias, Cardiac
;
Diagnosis
;
Electrocardiography*
;
Electrophysiology
;
Heart
;
Information Storage and Retrieval
;
Microcomputers
;
Statistics as Topic
;
Tachycardia
2.A Case of Pacemaker Implantation in Premature Newborn with Congenital Complete Atrioventricular Block.
Sang Hun BAEK ; So Yoon AHN ; Myung Sook LEE ; Young Mi HAN ; Se In SUNG ; Hye Soo YOO ; Eun Sun KIM ; Won Soon PARK ; Tae Gook JUN ; June HUH ; I Seok KANG ; Yun Sil CHANG
Journal of the Korean Society of Neonatology 2012;19(4):275-279
The congenital complete atrioventricular block(CCAVB) is a rare disease, which is the most serious complication of neonatal lupus erythematosus. Newborn with CCAVB are at risk of diminished cardiac output and the subsequent development of congestive heart failure. Transplacental steroid and beta-adrenergic agonist therapies are useful for the first and second degree atrioventricular block. But those therapies are usually not effective for complete atrioventricular block. If the fetus has a complete atrioventricular block, delivery should be considered unless other delivery contraindications. In this situation, early pacemaker implantation surgery can improve the survival rate of patients. We report one case of premature newborn with congenital complete atrioventricular block who is successfully recovered by pacemaker implantation.
Adrenergic beta-Agonists
;
Atrioventricular Block
;
Cardiac Output
;
Fetus
;
Heart Failure
;
Humans
;
Infant, Newborn
;
Lupus Erythematosus, Systemic
;
Rare Diseases
;
Survival Rate