1.Cerebello-Pontine Angle Lipoma: Case Report and Review of the Literature .
Hong Ju PARK ; Jin Suk YOO ; Hyang Ae SHIN ; Sang Gyun LIM
Journal of the Korean Balance Society 2006;5(2):228-291
Intracranial lipomas located in the cerebellopontine angle are extremely rare. These tumors are maldevelopmental lesions which can cause slowly progessive neurological symptoms. The clinical management of these tumours differs significantly from other lesions in this region. A 45 year old man presented with a 3-month history of vertigo and tinnitus in the left ear. In T1-weighted magnetic resonance imaging, the lesion was hyperintense and did not enhance after application of gadolinium. The patient was treated with medical therapy with good response. We present a review of the literature, with particular regard to management. Conservative treatment is recommended and limited surgery is usually indicated if the patients suffer from disabling neurological symptoms and signs e.g., vertigo, nausea, trigeminal neuralgia, facial weakness or facial spasm.
Cerebellopontine Angle
;
Ear
;
Gadolinium
;
Humans
;
Lipoma*
;
Magnetic Resonance Imaging
;
Middle Aged
;
Nausea
;
Spasm
;
Tinnitus
;
Trigeminal Neuralgia
;
Vertigo
2.A Case of Clear Cell Acanthoma.
Ho Gyun LEE ; Kwang Hyun CHO ; Yoo Shin LEE ; Eui Keun HAM ; Kye Young SONG ; Won Suk KIM
Korean Journal of Dermatology 1990;28(5):642-645
We report a case of clear cell acanthoma occurred in a 61 year old man. He developed a brownish bean sized nodule on the left chest 3 years ago. The skin lesion has slowly increased in size without any subjective symptoms. Histopathologic examination revealed proliferation of clear cells within a sharply demarcated area of the epidermis. The presence of numerous neutrophils throughout the epidermis were also noted.
Acanthoma*
;
Epidermis
;
Humans
;
Middle Aged
;
Neutrophils
;
Skin
;
Thorax
3.Nosocomial Infection Rate Comparison of Military and Civilian Intensive Care Units.
Sang Oh LEE ; Jae Gyun LIM ; Jin Ok PARK ; Hyung Suk NOH ; Jae Seok CHOI ; Alexander D SHIN
Korean Journal of Nosocomial Infection Control 2001;6(1):1-7
BACKGROUND: This study was undertaken to compare nosocomial infection rates between intensive care units of military and civilian hospitals. METHODS: From July to December 2000, we surveyed the intensive care unit of Armed Forces Capital Hospital (AFCH). We compared device use ratios and device-day infection rates with those of Korean Society for Nosocomial Infection Control (KOSNIC) and National Nosocomial Infections Surveillance (NNIS) system. RESULTS: During the period of study, 185 cases were admitted and 24 nosocomial infections were detected: 7 cases of pneumonia, 6 urinary tract, 3 blood stream, 3 cardiovascular system, 3 surgical site infections, 1 skin and soft tissue, and 1 central nervous system infection. Ventilator, urinary catheter and central venous catheter use ratios were 0.14 (95% confidence interval, 0.12-0.16), 0.58 (0.56-0.60) and 0.33 (0.31-0.35). The ratios of NNIS were 0.41, 0.67 and 0.50. Ventilator-, urinary catheter- and central venous catheter-day infection rates were 18.69(11.36-53.32), 6.65 (3.36-14.20) and 1.95 (1.44-9.92). However, the rates of KOSNIC were 9.93, 5.29 and 3.62. The rates of NNIS were 11.24, 6.14 and 5.55. CONCLUSIONS: In AFCH ventilators were used less frequently than NNIS, but more ventilator-associated pneumonia were developed than KOSNIC and NNIS.
Arm
;
Cardiovascular System
;
Central Nervous System Infections
;
Central Venous Catheters
;
Cross Infection*
;
Hospitals, Military
;
Humans
;
Intensive Care Units*
;
Critical Care*
;
Military Personnel*
;
Pneumonia
;
Pneumonia, Ventilator-Associated
;
Rivers
;
Skin
;
Urinary Catheters
;
Urinary Tract
;
Ventilators, Mechanical
4.Phase III Clinical Study of Recombinant Human Erythropoietin(Eporon(R)) on Anemia of Chronic Renal Failure.
Suk Hee YU ; Chong Myung KANG ; Kyung Won KANG ; Ho Young LEE ; Hyun Jin NOH ; Suk Gyun SHIN
Korean Journal of Nephrology 2000;19(6):1053-1062
To examine the effectiveness and safety of erythropoietin on the anemia of end-stage chronic renal failure, we administered recombinant human erythropoietin(rHuEPO), Eporon(R), to 66 patients with anemia and chronic renal failure who were undergoing hemodialysis or peritoneal dialysis. All received Eporon(R) intravenously, two or three times per week at 150unit/kg, and then the dose of Eporon(R) was adjusted to 75-300unit/kg/week according to the hemoglobin response. The results of this study judged 19(39.6%) of 48 patients as being in a "markedly improved" condition while 23(47.9%) of 48 patients were judged as being in an "improved" condition. At results, the response rate of this study was 87.5%(42/48 patients). This was the same as the target response rate, 90%(p= 0.564). Serious adverse events occured in 6 cases during the study, but all proved to be unrelated to Eporon(R). These events included itching 1(1.5%), urticaria 1(1.5%) and headache 1(1.5%). No patients discontinued to participate in the study except one patient who withdrew from the study voluntarily. The symptoms of all adverse events eventually decreased and disappeared during the clinical study. No factors in the clinical laboratory tests changed significantly (p<0.05) except for the decrease of TSR and ferritin, a consequence of using iron hemoglobin synthesis caused by Eporon(R) administration. The significant increase in blood pressure, which could not be proved to be related to Eporon(R), disappeared during the study. Anti-Epo antibody was not detected in any samples. These results demonstrate that Eporon(R) is effective in many patients with the anemia of end-stage chronic renal failure.
Anemia*
;
Blood Pressure
;
Erythropoietin
;
Ferritins
;
Headache
;
Humans*
;
Iron
;
Kidney Failure, Chronic*
;
Peritoneal Dialysis
;
Pruritus
;
Renal Dialysis
;
Urticaria
5.The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis.
Jin Young KIM ; Won Gyun JUNG ; Dong Min JEON ; Il Gyun SHIN ; Han Ki KIM ; Dong Oh SHIN ; Sang Ho KIM ; Tae Suk SUH
Korean Journal of Medical Physics 2009;20(3):139-144
Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.
Alloys
;
Arteries
;
Collodion
;
Computer Simulation
;
Exercise Test
;
Finite Element Analysis
;
Membranes
;
Stents
6.The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis.
Jin Young KIM ; Won Gyun JUNG ; Dong Min JEON ; Il Gyun SHIN ; Han Ki KIM ; Dong Oh SHIN ; Sang Ho KIM ; Tae Suk SUH
Korean Journal of Medical Physics 2009;20(3):139-144
Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.
Alloys
;
Arteries
;
Collodion
;
Computer Simulation
;
Exercise Test
;
Finite Element Analysis
;
Membranes
;
Stents
7.Deduction and Verification of Optimal Factors for Stent Structure and Mechanical Reaction Using Finite Element Analysis.
Dong Min JEON ; Won Gyun JUNG ; Han Ki KIM ; Sang Ho KIM ; Il Gyun SHIN ; Hong Seok JANG ; Tae Suk SUH
Korean Journal of Medical Physics 2010;21(2):201-208
Recently, along with technology development of endoscopic equipment, a stent has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. To this end, optimal factors are simulated for the stent structure and mechanical reaction and verified using finite element analysis. In order to compare to present commercialized product such as Zilver (Cook, Bloomington, Indiana, USA) and S.M.A.R.T (Cordis, Bridgewater Towsnhip, New Jersey, USA), mechanical impact factors were determined through Taguchi factor analysis, and flexibility and expandability of all the products including ours were tested using finite element analysis. Also, important factors were sought that fulfill the optimal condition using central composition method of response surface analysis, and optimal design were carried out based on the important factors. From the centra composition method of Response surface analysis, it is found that importat factors for flexibility is stent thickness (T) and unit area (W) and those for expandability is stent thickness (T). In results, important factors for optimum condition are 0.17 mm for stent thickness (T) and 0.09 mm2 for unit area (W). Determined and verified by finite element analysis in out research institute, a stent was manufactured and tested with the results of better flexibility and expandability in optimal condition compared to other products. Recently, As Finite element analysis stent mechanical property assessment for research much proceed. But time and reduce expenses research rarely stent of optimum coditions. In this research, Important factor as mechanical impact factor stent Taguchi factor analysis arrangement to find flexibility with expansibility as Finite element analysis. Also, Using to Center composition method of Response surface method appropriate optimized condition searching for important factor, these considering had design optimized. Production stent time and reduce expenses was able to do the more coincide with optimum conditions. These kind of things as application plan industry of stent development period of time and reduce expenses etc. be of help to many economic development.
Academies and Institutes
;
Finite Element Analysis
;
Indiana
;
New Jersey
;
Pliability
;
Stents
8.Treatment of Steatocystoma Multiplex on Whole Body: A Case Report.
Pal Young JANG ; Sang Ho SHIN ; Kyung Suk LEE ; Nam Gyun KIM ; Jun Sik KIM
Journal of the Korean Society of Plastic and Reconstructive Surgeons 2008;35(3):325-328
PURPOSE: Steatocystoma multiplex is a rare benign disease that occurred multiply on whole body surface. Many physicians have tried managing steatocystoma in variable methods. However it is hard to define the optimal way to cure steatocystoma. We performed both aspiration and excisional method to study the usefulness of both methods. METHODS: A 28-year-old woman has asymptomatic multiple subcutaneous nodules on whole body. Most lesions were aspirated with 26-guage needled 3cc syringe but large and purulent three nodules were excised. RESULTS: We diagnosed the lesion histologically as steatocystoma multiplex. Aspirated wound healed without scar, excised wound remained scar but esthetically acceptable. Axillary lesion contained so clustered type cysts that was difficult to aspirate whole cyst. Thus additional excisional method was needed. CONCLUSION: There are many practical methods to cure steatocystoma. However, there is no appropriate method to cure it. Therefore we should select different therapeutic method according to anatomical location and cyst size. Especially at subcutaneous fat-rich lesion like axilla and abdomen, it is better to excise the clustered cyst than to aspirate.
Abdomen
;
Adult
;
Axilla
;
Cicatrix
;
Female
;
Humans
;
Steatocystoma Multiplex
;
Syringes
9.Tracheal augmentation with Bovine pericardium.
Boo Yeon KIM ; Kyo Joon LEE ; Hwa Gyun SHIN ; Eung Suk LEE
The Korean Journal of Thoracic and Cardiovascular Surgery 2000;33(4):320-323
This case describes a tracheal stenosis complicated by endobronchial truberculosis. A 50-year-old female with progressive dyspnea was referred to us for the management of long segmental tracheal stenosis. Treatment modalities for tracheal stenosis include open surgical resectin and reconstruction, mechanical dilation, laser resection, and placement of an airway prosthesis. The following is a report of a successful treatment of a long segmental tracheal stenosis through a tracheal augmentation and the use of al Bovine pericardium. This technique may provide a relief from tracheal stenosis.
Dyspnea
;
Female
;
Humans
;
Middle Aged
;
Pericardium*
;
Prostheses and Implants
;
Tracheal Stenosis
10.Concurrent Two Types of Burn with Airbag in an Upper Extremity: Case Report.
Mun Young AN ; Jin Yong SHIN ; Si Gyun ROH ; Suk Choo CHANG ; Nae Ho LEE
Journal of Korean Burn Society 2017;20(2):68-70
Automobile airbags have been shown to reduce morbidity and mortality in the event of a vehicle crash; however, new problems have been identified. Among these problems, direct injury from the airbag itself has become a serious concern. This suggests that an airbag itself may not be safe. Burn injury from airbags accounts for about 7.8% of all injuries caused by vehicle crashes. There are three types of burn injuries from airbags: Thermal, chemical, and frictional. Moreover, there are three subtypes within the category of thermal airbag burn, as identified by Tsunetuki in 2003. Herein, we review a case of an airbag burn and report a unique burn case on ‘an upper extremity’, including both thermal and frictional burns.
Air Bags*
;
Automobiles
;
Burns*
;
Friction
;
Hot Temperature
;
Mortality
;
Upper Extremity*