1.Limb remote ischemic preconditioning attenuates lung injury in patients during one-lung ventilation
Zhentao SUN ; Ning WANG ; Yanan CAO ; Xueqing SUN ; Xueping HAN ; Suen REN
Chongqing Medicine 2017;46(6):764-766,769
Objective To investigate the effect of remote ischemic preconditioning (RIPC) on the lung injury during one-lung ventilation (OLV) in the patients undergoing thoracic surgery.Methods Eighty patients scheduled for elective radical operation for esophageal cancer,were randomly divided into 2 groups (n=40 each) using a random number table.control group (group C) and group RIPC.At 0 (T1),30 min (T2),1 h (T3) and 2 h (T4) of OLV,blood samples were obtained from the radial artery for blood gas analysis and determination of plasma concentrations of tumor necrosis factor-α (TNF-α),interleukin-1β (IL-1ββ) and IL-10.Oxygenation index(OI),respiratory index(RI) and PaO2/PAO2 were calculated.Exhaled breath condensate was collected and the pH value was measured.Results Compared with group C,Oxygenation index was significantly increased,and respiratory index was decreased at T2-T4,the plasma concentrations of TNF-α and IL-1β were decreased,and the pH value of exhaled breath condensate was increased at T3-T4,and the plasma concentration of IL-10 was increased at T4 in group RIPC.Conclusion RIPC can inhibit inflammatory responses and reduce airway acidification,thus attenuating the lung injury during OLV in the patients undergoing thoracic surgery.
2.The effects of different values of PEEP on heart index, stroke volume variation and oxygen transport index in patients monitored by FloTrac/Vigileo system
Zhentao SUN ; Ning WANG ; Xueqing SUN ; Dao XIANG ; Yanan CAO ; Xueping HAN ; Suen REN
Tianjin Medical Journal 2017;45(3):294-296
Objective To investigate the effects of different values of PEEP on cardiac index (CI), stroke volume variation (SVV) and oxygen transport index (DO2I) in patients monitored by FloTrac/Vigileo system, and to provide some references for the hemodynamic management and improvement of oxygenation for patients. Methods Sixty patients scheduled for elective television (TV) auxiliary thoracoscope radical operation for esophageal cancer were included in this study. Data of CI, SVV and DO2I were observed by the FloTrac/Vigileo system. Changes of CI, SVV and DO2I were recorded after anesthesia induction and turn left side (T0), artificial pneumothorax with 0 PEEP after 5 minutes (T1), artificial pneumothorax with 5 PEEP after 5 minutes (T2), artificial pneumothorax with 10 PEEP after 5 minutes (T3), and artificial pneumothorax with 15 PEEP after 5 minutes (T4). Results Compared with T0, CI decreased and SVV increased significantly at T1, T2, T3 and T4(P<0.05). Compared with T1, CI decreased and SVV increased at T4. DO2I increased at T2 and T3 compared with that of T1(P<0.05). Conclusion PEEP may have a certain influence on CI and SVV in the process of operation. The values of 5-10 PEEP can significantly improve oxygenation and have a less influence on hemodynamics, which can be appropriately used in clinical care.
3.Effect of operation position change on heart index and stroke volume variation in patients monitored by FloTrac/Vigileo system
Zhentao SUN ; Dao XIANG ; Ning WANG ; Yanan CAO ; Xueqing SUN ; Xueping HAN ; Suen REN
Chongqing Medicine 2017;46(31):4348-4349
Objective To investigate the effect of different operation positions on cardiac index (CI) and stroke volume variation (SVV) in the patients monitored by FloTrac/Vigileo system to provide some references for the hemodynamic management and liquid treatment of the patients.Methods Sixty patients scheduled for elective TV auxiliary thoracoscope radical operation of esophageal cancer.The CI and SVV changes were observed by using the FloTrac/Vigileo system.CI,SVV and CVP were recorded at 5 min after anesthesia induction (T0),5 min after converting to the position of head low feet high (T1),5 min after converting to the position of head high feet low (T2).Results Compared with T0,CI at T1 and T2 was decreased(P<0.05);compared with T0,SVV at T1 was decreased and CVP was increased;SVV at T2 was increased and CVP was decreased(P<0.05).Conclusion The operation position change may have a significant impact on the patient's CI,SVV and CVP.Focusing on the corresponding change can provide some references for the intraoperative hemodynamic management and liquid treatment.