1.Clinical, Laboratory and Epidermiology Feature of Human Rota Virus(HRV) Gastroenteritis.
Bok Hee OH ; Soo Jee MOON ; Keun Soo LEE
Journal of the Korean Pediatric Society 1983;26(10):959-966
No abstract available.
Gastroenteritis*
;
Humans*
3.Antiviral Effect of Antisense Phosphorothioate Oligonucleotides Targeted to Herpes Simplex Virus.
Yoo Chul LEE ; Soo Jee KIM ; Yoo Jin CHO
Journal of the Korean Society for Microbiology 1999;34(3):233-243
To search the effective antisense oligonucleotide that inhibit the growth of Herpes simplex virus type 1 (HSV-1), six kinds of phosphorothioate oligodeoxynucleotides (S-ODNs) were synthesized and the antiviral activity was assessed by measuring cytopathic effect in Vero cells infected with HSV-1. Of the three dodecamer S-ODNs, cornplernentary to the translation initiation site of IE2 (AS2) and scrambled S-ODN (AS1) showed more significant antiherpetic activity than AS4 complementary to the IE4. Accordingly, the antiviral effect of dodecamer S-ODN was not specific. In contrast to the no inhibitory effect of sense strand S-ODN of ICP8 (AS6), two S-ODNs complementary to the translation initiation site of ICP8 (AS3) and that of IE1 (AS5) showed potent antiherpetic activity assessed in vitro HSV-1 virus yield assay. Antiherpetic effect of AS3 was decreased in proportion to the addition of AS6. The synthesis of viral protein ICPS and IE1 were inhibited in AS3 and AS5 treated HSV-1 infected Vero cells, respectively. These findings suggest that antiherpetic effect of AS3 is specifically mediated by targeting ICPS. S-ODNs had no effect on Vero cell viability. The data suggest that the 19-mer S-ODNs may be effective in antiviral chemotherapy.
Drug Therapy
;
Herpes Simplex*
;
Herpesvirus 1, Human
;
Oligodeoxyribonucleotides
;
Phosphorothioate Oligonucleotides*
;
Simplexvirus*
;
Vero Cells
4.Intermittent Hydronephrosis.
Hong Kun KIM ; Woo Gill LEE ; Soo Jee MOON
Journal of the Korean Pediatric Society 1987;30(7):805-811
No abstract available.
Hydronephrosis*
5.Accuracy of the sphygmomanometer for measuring of blood pressure.
Seok Whan LEE ; Soo Jee KIM ; Jong Uk HWANG
Journal of the Korean Academy of Family Medicine 1997;18(12):1500-1507
BACKGROUND: Recently, it is substituted automatic sphygmomanometer for mercury sphygmomanometer. But it seems to be insufficient for data of its accuracy. A sample accurate automatic sphygmomanometer could have an important role in the management of hypertension. The aim of this study is to assess the accuracy of the automatic sphygmomanometer that is used common practice and at home. METHODS: We collected 247 patients who visited the department of Famiiy Practice of Taegu medical center from April to August 1996. BP was measured sequentially same arm by standard device(mercury. sphygmomanometer), test device A(A&D TM-2650), test device B(seine SE-2000). We assessed the automatic sphygmomanometer according to the standards set out by the British Hypertension Society(BHS) protocol and the American Association for the Advancement of Medical Instrumentation(AAMI). These data were analysed using pearson' correlation and paired t-test. RESULTS: Test device A was highly correlated to mercury sphygmomanometer in systolic and diastolic BP(r=0.90, r=0.88). Also test device B was highly correlated to that(r=0.90, r=0.87). The mean difference between BP value obtained by the standard device and those obtained by the test device A were 0.59+/-7.66mmHg systole(mean+/-SD) and 3.83+/-6.43mmHg diast.ole, whereas the difference between the former and those obtained by the test device B were 1.70+/-7.99mmHg systole.and 5.58+/-6.38mmHg diastole. Comparing to standard device, there were a signifioant difference except systolic BP of test device A(P<0.05). According to the criteria of the AAMI, the diastolic BP of test device B was not enough and according to the criteria of the BHS, the diastolic BP of both test device were not enough. CONCLUSIONS: Both test device were highly correlated to mercury sphygmomanometer. But according to the criteria of the BHS and AAMI, there were not enough. Because the use of automatic sphygmomanometer was popularized, I think that further study will be required to assess of accuracy.
Arm
;
Blood Pressure*
;
Daegu
;
Diastole
;
Humans
;
Hypertension
;
Sphygmomanometers*
6.Lateral Ventricular Indices in tuberculous Meningitis.
Ja Wook KOO ; Hang Bo CHO ; In Joon SEOL ; soo Jee MOON ; Hahng LEE ; Keun Soo LEE
Journal of the Korean Pediatric Society 1988;31(8):984-991
No abstract available.
Tuberculosis, Meningeal*
7.A Prospective Study of Urinary beta2 -Microglobulin in Infants with Meconium-Stained Amniotic Fluid.
Sung Oh KIM ; Jeh Hoon SHIN ; Woo Gill LEE ; Soo Jee MOON ; Keun Soo LEE
Journal of the Korean Pediatric Society 1988;31(8):968-976
No abstract available.
Amniotic Fluid*
;
Female
;
Humans
;
Infant*
;
Prospective Studies*
8.A Biomechanical Study on the Pull-Out Strength of Pedicle Screw Augmented with Polymethylmethacrylate(PMMA)- Cadaveric Study -.
Jee Soo JANG ; Sang Ho LEE ; Kyung Tae KIM ; Byung Soo KIM ; Won Bok LEE
Journal of Korean Neurosurgical Society 2002;31(1):45-49
OBJECTIVE: The authors evaluate the differences in the pedicle screw pull-out strength between an unaugmented screw and a screw augmented by high pressurized PMMA in an embalmed human lumbar cadaveric spine. METHODS: Pedicle screws were inserted in the 50 pedicles of cadaver lumbar spine after measuring the bone mineral density(BMD) of the specimens. The pedicle screw was inserted without augmentation on the left pedicle and with augmentation by a vertebral reconstruction with high pressurized PMMA on the right side. The pedicle screw was inserted before the hardening of bone cement on the right side. A computed tomographic scan was done to evaluate the location of the PMMA and PMMA/ screw interface. After that, a screw pullout strength test was performed. RESULTS: There were positive correlations between the pull-out strength and BMD in the control group (r=0.7339). The average pull-out strength of the augmented group was 168% greater than that of the control group(p<0.05). The pull-out strength of the augmented group was correlated with in the volume of the PMMA. CONCLUSION: A pedicle screw that is augmented with PMMA will provide a more rigid fixation than that of an unaugmented screw, especially in the low BMD group of the specimens.
Cadaver*
;
Humans
;
Polymethyl Methacrylate
;
Spine
9.Neonatal Campylobacter enteritis.
Tae Jin PARK ; Woo Gill LEE ; Soo Jee MOON ; Keun Soo LEE
Journal of the Korean Pediatric Society 1984;27(10):965-970
No abstract available.
Campylobacter*
;
Enteritis*