1.Detection of Exogenous γ-Hydroxybutyric Acid in Rat Blood Exosomes.
Zheng-Xiang GAO ; Qi-Zhi LUO ; Liang ZHANG ; Mao-Qing PEI ; Hui-Jun WANG ; Xia YUE
Journal of Forensic Medicine 2022;38(2):212-216
OBJECTIVES:
To find a method to distinguish exogenous gamma-hydroxybutyrate (GHB) from endogenous GHB by establishing ultra-high performance liquid chromatography-mass spectrometry (UPLC-MS) based on exosome for quantitative detection of GHB in the rat blood.
METHODS:
Adult male SD rats were divided into 1 h, 5 h, 10 h administration group and control group. After 1 h, 5 h and 10 h of single precursor of GHB gamma-butyrolactone (GBL) intraperitoneal injection in administration groups, 5 mL blood was collected from the abdominal aorta. Meanwhile, the control group was given a same dose of normal saline, and 5 mL blood was collected at 1 h. Among the 5 mL blood, 0.5 mL was directly detected by HPLC-MS after pretreatment, and exosomes were extracted from the remaining blood by differential centrifugation and detected.
RESULTS:
The concentration of GHB in the control group was (87.36±33.48) ng/mL, and the concentration with administration at 1 h, 5 h and 10 h was (110 400.00±1 766.35) ng/mL, (1 479.00±687.01) ng/mL and (133.60±12.17) ng/mL, respectively. The results of exosome detection showed that no peak GHB signal was detected in the control group and the 10 h administration group, and the concentrations of GHB at 1 h and 5 h administration groups were (91.47±33.44) ng/mL and (49.43±7.05) ng/mL, respectively.
CONCLUSIONS
GHB was detected in blood exosome by UPLC-MS, which indicated that exogenous GHB could be detected in plasma exosomes, while endogenous GHB could not be detected, suggesting that this method may be used as a basis to determine whether there is exogenous drug intake.
4-Butyrolactone/chemistry*
;
Animals
;
Chromatography, Liquid
;
Exosomes/chemistry*
;
Hydroxybutyrates/chemistry*
;
Male
;
Rats
;
Rats, Sprague-Dawley
;
Sodium Oxybate/analysis*
;
Tandem Mass Spectrometry/methods*
2.Detection of gamma-hydroxybutyrate (GHB) in beverages.
Wei LIU ; Min SHEN ; Ping XIANG ; Jun BU ; He-Jian WU
Journal of Forensic Medicine 2007;23(2):120-129
OBJECTIVE:
To establish an analytical method for the determination of GHB in beverages using GC/MS and LC/MS/MS.
METHODS
After beverage samples with GHB-d6 as the internal standard were extracted with ethyl acetate, then the extracts were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), at last the derivateized extracts analyzed by gas chromatography- mass spectrometry. After beverage samples with GHB-d6 as the internal standard were diluted by mobile phase then directly analyzed by LC/MS/MS. Results The limit of detection was 0.2 microg/mL and both relative standard deviations for between-day and within-day assays were < 8.54% in GC/MS. The limit of detection was 2 microg/mL and both relative standard deviations for between-day and within-day assays were <8.62% in LC/MS/MS. Conclusion These methods of qualitative and quantitative analysis were found to be sensitive, accurate, rapid and suitable for the forensic toxicology to test of GHB in real cases.
Anesthetics, Intravenous/analysis*
;
Beverages/analysis*
;
Forensic Medicine/methods*
;
Gas Chromatography-Mass Spectrometry/methods*
;
Humans
;
Hydrogen-Ion Concentration
;
Reproducibility of Results
;
Sensitivity and Specificity
;
Sodium Oxybate/chemistry*
;
Substance Abuse Detection/methods*