1.In vitro study on Coxsackie virus B3 infection on islet cells
Mingwei SHENG ; Sisi CHEN ; Sheng BAI ; Yu ZHENG ; Xiaomian LI
Chinese Journal of Microbiology and Immunology 2011;(3):229-233
Objective To study the effect of Coxsackie virus B3 (CVB3) infection on islet cells in vitro, and to explore the mechanism of islet cells caused by CVB3. Methods Bone marrow mesenchymal stem cells( BMSCs) were separated from the bone marrow and cultured. Then they were induced to differentiate into islet-like cells using nicotinamide and mercaptoethanol. Differentiated cells were detected by morphology , special staining and RT-PCR. Observe CVB3 infection on islet cells under inverse microscope and detect the specific gene fragment by RT-PCR. Results BMSCs showed half suspended shape and gathered to form a cluster after induction. Cells became red brown by dithizone specific staining. RT-PCR also proved the existence of mRNA expressing insulin. Infected islet cells appeared typical pathological changes like shrinks, refraction decreases. RT-PCR detected the desired specific gene fragment of 299 bp in infected islet cells. Conclusion CVB3 can directly injury islet cells, and damage the function of islet cells of secreting insulin.
2.Angular dose dependency of MatriXX and its calibration
Qixin LI ; Penggang BAI ; Xiuchun ZHANG ; Kaiqiang CHEN ; Sisi ZHANG
Chinese Journal of Radiological Medicine and Protection 2011;31(2):229-232
Objective To characterize angular dependency of MatfiXX and develop a method for its calibration in order to verify treatment plan with original gantry angles.Methods Absolute dose calibration was carried with thimble ionization chamber on the linear accelerator.so as to make sure 1 MU=1 cGy at the depth of maximum dose(dmax).A MatriXX was put into a Mutlicube phantom,and the ionization chamber matrix was calibrated with absolute dose.In order to determine a correction factor CF as a function of gantry angle θ.open beam fields of 10 cm×10 cm size were irradiated for gantry angles θ=0°-180°(every 5°)and every 1°for lateral angles θ in the range of 85°-95°.CF was defined as the ratio of the dose measured with ionization chamber and the dose from MatriXX.Results Relatively large discrepancies in response to posterior VS.anterior fields for MatriXX detectors(up to 10%)were found during the experiment and relatively large variability of response as a function of gantry angle.The pass rate of treatment plan in lateral beams was lower than that of other beams.The isodose distribution of corrected MatriXX matched well with the outcome from the treatment planning system. Conclusions The angular dose dependency of MatriXX must be considered when it is used to verify the treatment plan with original gantry angles.
3.Dose calculation on kilovoltage cone-beam CT imaging for head and neck radiotherapy
Qixin LI ; Penggang BAI ; Chuanben CHEN ; Jianji PAN ; Xiuchun ZHANG ; Zhaodong FEI ; Sisi JIANG
Chinese Journal of Radiation Oncology 2011;20(4):334-337
Objective To study the feasibility of dose calculation using kilovoltage X-ray cone-beam CT (KVCBCT) imaging for head-and-neck radiation therapy.Methods 11 patients with nasopharyngeal carcinoma were scanned with KVCBCT to adjust position before treatment, and rescanning images with KVCBCT after correction were input a treatment-planning system.The dose was recalculated by applying the patients′ treatment plans based on planning CT to the KVCBCT images.The dose distributions and dose volume histograms (DVH) of the tumor and critical structures were compared with the original treatment plan.Results The DVH and dose distribution of the plan based on the KVCBCT are compared with that of the planning CT, and they shows a good consistency for the 11 cases.The doses calculated from the planning CT and KVCBCT were compared on the isocenter planes.Using γ analysis with a criterion of 3%/3 mm, 98.0%±1.33% of the points on the isocenter planes in the planning CT and KVCBCT.The difference of the dose to target volume was<1% and to normal structure was<2%.Conclusions This study indicated that CBCT images can be used to make a treatment plan with its individual hounsfield unit-electron density calibration curve.
4.Optimization of a forensic DNA extraction kits and its applicability evaluation
Yiren YAO ; Xue BAI ; Jimin XU ; Youzheng WANG ; Yongmin YU ; Sisi ZHANG ; Xingchun ZHAO
Chinese Journal of Forensic Medicine 2016;31(6):595-597,598
Objective To construct a rapid genetic DNA extraction method, with nano magnetic beads, self-designed reagents system and extracting process. Method Part I: DNA extraction from old blood cotton swab sample with self-designed DNA extraction kit, then quantiifed by UV spectrophotometer. The method was further optimized on the preliminary results. Part II: All kinds of difficult DNA sample were tested with optimized kit, to detect the applicability of the kit. Result By improving the experimental condition, the extraction effects of different DNA sample is good, meanwhile, the extraction cost is relatively low.
6.Analysis of setup error in the head and neck cancer radiotherapy using cone-beam CT scanning.
Sisi JIANG ; Yiyan QU ; Penggang BAI ; Qixin LI ; Chuanben CHEN ; Libin LIU ; Zhaodong FEI
Journal of Biomedical Engineering 2012;29(5):851-854
Cone-beam CT (CBCT) of Elekta can be used to analyze the setup errors in intensity modulated radiotherapy. A total of 240 patients with head and neck cancer were chosen in the period from October, 2009 to October, 2010. Their CBCT images were obtained after initial setup, and registered to the planning CT images, and then the setup errors on translational directions (X, Y, Z) and on rotational directions (U, V, W) were obtained and analyzed. The results showed that the setup errors on translational directions in Y-axis and Z-axis were larger than in X-axis, and the setup errors on rotational directions in Y-axis was much more obvious than those on the other two directions, which should be taken care during the patient daily setup. It may be concluded that the CBCT system can improve the precision for radiotherapy.
Cone-Beam Computed Tomography
;
methods
;
Head and Neck Neoplasms
;
diagnostic imaging
;
radiotherapy
;
Humans
;
Radiotherapy Setup Errors
;
prevention & control
;
statistics & numerical data
;
Radiotherapy, Intensity-Modulated
7.Design of Remote Slit Lamp Diagnosis Platform Based on IoT Technology
Tianxing QUE ; Sisi BAI ; Jingru LI ; Shuangshuang CAI ; Shuang LIAN ; Zhipeng YE ; Hao CHEN ; Peipei JIANG
Chinese Journal of Medical Instrumentation 2024;48(2):232-236
In order to realize the diagnosis of slit lamp in cross-regional patients and improve the real-time and convenience of diagnosis,a remote slit lamp diagnosis platform based on Internet of Things(IoT)technology is designed.Firstly,the feasibility of remote slit lamp is analyzed.Secondly,the IoT platform architecture of doctor/server/facility(D/S/F)is proposed and a remote slit lamp is designed.Finally,the performance of the remote slit lamp diagnostic platform is tested.The platform solves the communication problem of distributed slit lamps and realizes respectively numerical control of multi-area slit lamp by multi-eye experts.The test results show that the remote control delay of the platform is less than 20 ms,which supports multiple experts to diagnose multiple patients separately.
8.Application and effect evaluation of WeChat platform in the diagnosis and treatment training of gynecologists
Lele MAO ; Sisi XI ; Xing CHEN ; Yu SUN ; He DIAO ; Wenpei BAI
Chinese Journal of Medical Education Research 2020;19(3):340-344
Objective:To evaluate the effect of WeChat platform in the diagnosis and treatment of menopausal-related diseases for gynecologists.Methods:In March 2017, 47 gynecologists who voluntarily participated in the offline continuing medical education project "Diagnosis and Treatment training of menopause-related diseases" in Beijing Shijitan Hospital Affiliated to Capital Medical University were selected as the control group (traditional teaching mode), and 52 gynecologists who volunteered to participate in WeChat platform training were selected as the experimental group (WeChat teaching mode). The main outcome measure was the knowledge level of menopause-related diseases and curriculum satisfaction before and after training. SPSS was used to perform t-test or chi-square test for inter-group data. Results:All gynecologists completed the study, the recovery rate of the evaluation questionnaire before and after training was 100%. Before training, the average score of menopause-related disease knowledge and the test passing rate of knowledge examination in experimental group were (63.65±21.42) and 65.4%, while those in the control group were (60.85±24.83) and 63.8%, respectively. No significant difference was found ( P>0.05). After training, the knowledge level of menopause-related diseases and the test passing rate significantly improved in both groups ( P<0.05). The average score of students and the passing rate in the experimental group were (77.50±16.19) and 90.1%, which were better than those in the control group [(78.72±16.89), 87.2%]. However, there was no significant difference between the two groups ( P>0.05). Besides, the experimental group was more satisfied, but the difference was not statistically significant compared with control group ( P>0.05). Conclusion:WeChat platform training for gynecologists not only has the same effects as the traditional teaching model on menopausal disease diagnosis and treatment training, but also gains higher training satisfaction, suggesting WeChat platform training can be further applied to other subdisciplines.
9.Effect of high expression of miR-1269 in non-small cell lung cancer tissues on biological characteristics of lung cancerA549 cells
DAI Suli ; BAI Hanyu ; WANG Yaojie ; WEI Sisi ; CHEN Liang ; ZHANG Cong ; ZHAO Lianmei ; SHAN Baoen
Chinese Journal of Cancer Biotherapy 2018;25(12):1282-1289
Objective: To investigate the expression of miR-1269 in non-small-cell lung cancer (NSCLC) tissues, and to explore its effect on the cellular biological characteristics of NSCLC A549 cells and the underlying mechanism. Methods: 34 pairs of NSCLC tissues and the corresponding adjacent para-cancerous tissues obtained from the patients, who underwent surgery in the Department of Breast Surgery, the Fourth Hospital of Hebei Medical University from Jan. 2017 to Jan. 2018, were collected for this study. The expression level of miR-1269 in above tissue specimens was examined by real-time fluorescent quantitative PCR.After transfection with miR1269 mimics and mimics NC (negative control), the proliferation, migration and invasion of A549 cells were detected by MTS, Wound healing and Transwell assay, respectively; and the changes in cell cycle distribution of A549 cells were examined by flow cytometry. The bioinformatics tool was used to predict the possible target gene of miR-1269, and the regulation effect of miR-1269 on target gene was then validated by Western blotting and Dual-luciferase reporter assay. In the meanwhile, the protein expressions of cyclin depen
dent kinase inhibitor p21, Cyclin D2, and EMT-related proteins (E-cadherin and ZEB2) in the transfected A549 cells were measured by Western blotting. Results: The expression level of miR-1269 in NSCLC tissues was significantly higher than that in paracancerous tissues (2.81±2.27 vs 1.61±1.36, P <0.05). The capacities of proliferation, migration and invasion ofA549 cells in miR-1269 mimics transfection group were significantly higher than those in mimics NC group and blank control group (all P <0.01). And the cell proportion at S-phase in miR-1269-mimics group was obviously higher than that in mimics NC group [(46.54±1.57)% vs (23.32±3.15)%, P<0.01]. Bioinformatics analysis showed that miR-1269 could combine with 3’UTR of FOXO1 gene. After transfection with miR-1269 mimics, the expression level and luciferase activity of FOXO1 protein in A549 cells were significantly reduced (all P <0.01). Moreover, the protein expressions of p21 and E-cadherin were significantly decreased after over-expression of miR-1269 (all P <0.05), while the expressions of ZEB2 and Cyclin D2 were up-regulated (all P <0.05). Conclusion: The expression level of miR-1269 in NSCLC tissues was significantly increased, and it could enhance the proliferation, cell cycle progression, migration and invasion ofA549 cells. The possible mechanism may be related to its targeted regulation of FOXO1.