1.Use of a new low-profile coronary stent graft for the treatment of intracranial carotid blow-out
Halil Ibrahim ALTUNBULAK ; Ahmet Yasir ALTUNBULAK ; Sinan BALCI ; Mustafa BERKER ; Anil ARAT
Journal of Cerebrovascular and Endovascular Neurosurgery 2024;26(4):399-404
A 50-year-old male patient with a history of transcranial surgery and subsequent radiotherapy for a pituitary adenoma presented with repetitive pulsatile nasal bleeding. A right cavernous segment pseudoaneurysm was discovered on the angiogram, and the patient failed the balloon occlusion test. A Papyrus (Biotronik, Berlin, Germany) stent graft, which is approved for coronary interventions, was successfully deployed over a coaxial guiding system during the emergent treatment of the false aneurysm. The patient tolerated the procedure well and nasal bleeding did not recur after the procedure. At one-year angiographic follow-up, the stent graft was patent and there was no evidence of recanalization of the false aneurysm.
2.Use of a new low-profile coronary stent graft for the treatment of intracranial carotid blow-out
Halil Ibrahim ALTUNBULAK ; Ahmet Yasir ALTUNBULAK ; Sinan BALCI ; Mustafa BERKER ; Anil ARAT
Journal of Cerebrovascular and Endovascular Neurosurgery 2024;26(4):399-404
A 50-year-old male patient with a history of transcranial surgery and subsequent radiotherapy for a pituitary adenoma presented with repetitive pulsatile nasal bleeding. A right cavernous segment pseudoaneurysm was discovered on the angiogram, and the patient failed the balloon occlusion test. A Papyrus (Biotronik, Berlin, Germany) stent graft, which is approved for coronary interventions, was successfully deployed over a coaxial guiding system during the emergent treatment of the false aneurysm. The patient tolerated the procedure well and nasal bleeding did not recur after the procedure. At one-year angiographic follow-up, the stent graft was patent and there was no evidence of recanalization of the false aneurysm.
3.Use of a new low-profile coronary stent graft for the treatment of intracranial carotid blow-out
Halil Ibrahim ALTUNBULAK ; Ahmet Yasir ALTUNBULAK ; Sinan BALCI ; Mustafa BERKER ; Anil ARAT
Journal of Cerebrovascular and Endovascular Neurosurgery 2024;26(4):399-404
A 50-year-old male patient with a history of transcranial surgery and subsequent radiotherapy for a pituitary adenoma presented with repetitive pulsatile nasal bleeding. A right cavernous segment pseudoaneurysm was discovered on the angiogram, and the patient failed the balloon occlusion test. A Papyrus (Biotronik, Berlin, Germany) stent graft, which is approved for coronary interventions, was successfully deployed over a coaxial guiding system during the emergent treatment of the false aneurysm. The patient tolerated the procedure well and nasal bleeding did not recur after the procedure. At one-year angiographic follow-up, the stent graft was patent and there was no evidence of recanalization of the false aneurysm.
4.The Association between Whole Blood Viscosity and Coronary Collateral Circulation in Patients with Chronic Total Occlusion.
Mehmet Serkan CETIN ; Elif Hande OZCAN CETIN ; Kevser Gülcihan BALCI ; Selahattin AYDIN ; Emek EDIBOGLU ; Muhammed Fatih BAYRAKTAR ; Mustafa Mücahit BALCI ; Orhan MADEN ; Ahmet TEMIZHAN ; Sinan AYDOGDU
Korean Circulation Journal 2016;46(6):784-790
BACKGROUND AND OBJECTIVES: Coronary collateral circulation (CCC) has been attributed as inborn bypass mechanisms supporting ischemic myocardium. Various factors have been postulated in CCC. Whole blood viscosity (WBV) has been an underappreciated entity despite close relationships between multiple cardiovascular diseases. WBV can be calculated with a validated equation from hematocrit and total plasma protein levels for a low and high shear rate. On the grounds, we aimed to evaluate the association between WBV and CCC in patients with chronic total occlusion. SUBJECTS AND METHODS: A total of 371 patients diagnosed as having at least one major, chronic total occluded coronary artery were included. 197 patients with good CCC (Rentrop 2 and 3) composed the patient group. The poor collateral group consisted of 174 patients (Rentrop grade 0 and 1). RESULTS: Patients with poor CCC had higher WBV values for a low-shear rate (LSR) (69.5±8.7 vs. 60.1±9.8, p<0.001) and high-shear rate (HSR) (17.0±2.0 vs. 16.4±1.8, p<0.001) than the good collateral group. Correlation analysis demonstrated a significant negative correlation between the grade of CCC and WBV for LSR (β=0.597, p<0.001) and HSR (β=0.494, p<0.001). WBV for LSR (β=0.476, p<0.001) and HSR (β=0.407, p<0.001) had a significant correlation with the synergy between percutaneous coronary intervention with taxus and cardiac surgery (SYNTAX) score. A multivariate analysis showed that the WBV for both shear rates were independent risk factors of poor CCC (WBV at LSR, OR: 1.362 CI 95%: 1.095-1.741 p<0.001 and WBV at HSR, 1.251 CI 95%: 1.180-1.347 p<0.001). CONCLUSION: WBV has been demonstrated as the overlooked predictor of poor coronary collateralization. WBV seemed to be associated with microvascular perfusion and angiogenesis process impairing CCC development.
Blood Viscosity*
;
Cardiovascular Diseases
;
Collateral Circulation*
;
Coronary Vessels
;
Hematocrit
;
Humans
;
Multivariate Analysis
;
Myocardium
;
Percutaneous Coronary Intervention
;
Perfusion
;
Plasma
;
Risk Factors
;
Taxus
;
Thoracic Surgery
5.The Presence of Fragmented QRS on 12-Lead Electrocardiography in Patients with Coronary Artery Ectasia.
Fatih SEN ; Samet YILMAZ ; Mevlut Serdar KUYUMCU ; Ozcan OZEKE ; Mustafa Mucahit BALCI ; Sinan AYDOGDU
Korean Circulation Journal 2014;44(5):307-311
BACKGROUND AND OBJECTIVES: Coronary artery ectasia (CAE) is an angiographic finding characterized by dilation of an arterial segment with a diameter at least 1.5 times that of its adjacent normal coronary artery. Fragmented QRS (fQRS) complexes are electrocardiographic signals which reflect altered ventricular conduction around regions of a myocardial scar and/or ischaemia. In the present study, we aimed to evaluate the presence of fQRS in patients with CAE. SUBJECTS AND METHODS: The study population included 100 patients with isolated CAE without coronary artery disease (CAD) and 80 angiographically normal controls. fQRS was defined as the presence of an additional R wave or notching of R or S wave or the presence of fragmentation in two contiguous leads corresponding to a major coronary artery territory. RESULTS: The two groups were similar in terms of age, sex, hypertension, dyslipidemia, and family history of CAD. The presence of fQRS was significantly (p<0.05) higher in the CAE group than that in the normal coronary artery group (29% vs. 6.2%, p=0.008). Isolated CAE were detected most commonly in the right coronary artery (61%), followed by left anterior descending artery (52%), left circumflex artery (36%), and left main artery (9%). Multivariate stepwise logistic regression analysis showed that CAE {odds ratio (OR) 1.412; 95% confidence interval (CI) 1.085-1.541; p=0.003} and diabetes (OR 1.310; 95% CI 1.025-1.482; p=0.041) were independently associated with fQRS. CONCLUSION: The presence of fragmented QRS associated with increased risk for arrhythmias and cardiovascular mortality was significantly higher in patients with CAE than in patient with normal coronary artery. Further studies are needed to determine whether the presence of fragmented QRS is a possible new risk factor for patients with CAE.
Angiography
;
Arrhythmias, Cardiac
;
Arteries
;
Cicatrix
;
Coronary Artery Disease
;
Coronary Vessels*
;
Dilatation, Pathologic*
;
Dyslipidemias
;
Electrocardiography*
;
Humans
;
Hypertension
;
Logistic Models
;
Mortality
;
Risk Factors